Toluwanimi Oluwadara Akinyemi

Mr. Toluwanimi Oluwadara Akinyemi

Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
+1
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2020 in Micromachines
Verified
Journal Article
Open access
PDF file
SHShipeng Han
Shipeng Han
ZMZhen Meng
Zhen Meng
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
YYYuepeng Yan
Yuepeng Yan
Research and industrial studies have indicated that small size, low cost, high precision, and ease of integration are vital features that characterize microelectromechanical systems (MEMS) inertial sensors for mass production and diverse applications. In recent times, sensors like MEMS accelerometers and MEMS gyroscopes have been sought in an increased application range such as medical devices for health care to defense and military weapons. An important limitation of MEMS inertial sensors is repeatedly documented as the ease of being influenced by environmental noise from random sources, along with mechanical and electronic artifacts in the underlying systems, and other random noise. Thus, random error processing is essential for proper elimination of artifact signals and improvement of the accuracy and reliability from such sensors. In this paper, a systematic review is carried out by investigating different random error signal processing models that have been recently developed for MEMS inertial sensor precision improvement. For this purpose, an in-depth literature search was performed on several databases viz., Web of Science, IEEE Xplore, Science Direct, and Association for Computing Machinery Digital Library. Forty-nine representative papers that focused on the processing of signals from MEMS accelerometers, MEMS gyroscopes, and MEMS inertial measuring units, published in journal or conference formats, and indexed on the databases within the last 10 years, were downloaded and carefully reviewed. From this literature overview, 30 mainstream algorithms were extracted and categorized into seven groups, which were analyzed to present the contributions, strengths, and weaknesses of the literature. Additionally, a summary of the models developed in the studies was presented, along with their working principles viz., application domain, and the conclusions made in the studies. Finally, the development trend of MEMS inertial sensor technology and its application prospects were presented.

12 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
WDWenke Duan
Wenke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
WDWenjing Du
Wenjing Du
JMJun Ma
Jun Ma
XCXing-Yu Chen
Xing-Yu Chen
Lei WangLei Wang
Lei Wang
Prior methods of patient care have changed in recent years due to the availability of minimally invasive surgical platforms for endovascular interventions. These platforms have demonstrated the ability to improve patients’ vascular intervention outcomes, and global morbidities and mortalities from vascular disease are decreasing. Nonetheless, there are still concerns about the long-term effects of exposing interventionalists and patients to the operational hazards in the cath lab, and the perioperative risks that patients undergo. For these reasons, robot-assisted vascular interventions were developed to provide interventionalists with the ability to perform minimally invasive procedures with improved surgical workflow. We conducted a thorough literature search and presented a review of 130 studies published within the last 20 years that focused on robot-assisted endovascular interventions and are closely related to the current gains and obstacles of vascular interventional robots published up to 2022. We assessed both the research-based prototypes and commercial products, with an emphasis on their technical characteristics and application domains. Furthermore, we outlined how the robotic platforms enhanced both surgeons’ and patients’ perioperative experiences of robot-assisted vascular interventions. Finally, we summarized our findings and proposed three key milestones that could improve the development of the next-generation vascular interventional robots.

19 February 2021 in IEEE Sensors Journal
Verified
Journal Article
Closed access
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWenke Duan
Wenke Duan
GLGan Lu
Gan Lu
YAYousef Al-handarish
Yousef Al-handarish
Lei WangLei Wang
Lei Wang
The adoption of non-surgical procedures for the treatment of cardiovascular diseases has yielded several benefits such as lesser perioperative pain, shorter hospital stay, and faster recovery time while introducing radiation-specific, orthopedic, force-related health risks etc. during manual procedures. To address these challenges, robotic catheter systems were unveiled for better procedural outcomes while also offering a vast decline in orthopedic and radiation risks witnessed aforetime. However, distal force sensing and feedback acquisition were lacking in most of these systems. Currently, miniaturized force-sensing catheters for smart catheterization and acquisition of tool-tissue or tool-vessel contact force rely mostly on electrical or optical-based approaches with fiber Bragg grating (FBG) sensing technique receiving an increased attention lately. Hence, this paper presents an extensive overview of FBG-based distal force sensors for both conventional and robot-assisted cardiac interventions with emphasis on its fundamental principles, progressive development, design methodology, significance, as well as current challenges. In addition, the safety and feasibility of existing robotic catheter systems was analyzed based on existing studies. An outlook on future improvement of robotic catheter systems and adoption of FBG-based distal force sensors for wider minimally invasive applications were presented.

1 January 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
LGLu Gan
Lu Gan
WDWen ke Duan
Wen ke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
WDWenjing Du
Wenjing Du
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
Lei WangLei Wang
Lei Wang
In this paper, a one-dimensional distal force sensor design is proposed for minimally invasive surgery based on fiber Bragg grating (FBG) sensing principle. The sensor is made with a miniaturized force-sensitive flexure within which an optical fiber is embedded. The former includes a spiral elastomer utilized for high axial force sensitivity, while the fiber includes dual FBGs that are tightly suspended around the distal parts of the flexure and along elastomer’s centerline, respectively. Theoretical model of the flexure was derived based on its components and a design approach for decoupling strain and temperature cross-effects during sensor usage. In addition, design parameters of the flexure were analyzed on physics-based model optimization using fmincon function, while the static and dynamic properties were analyzed in-silico using finite element method. Further experiments were also carried out to analyze the sensor’s performance, and the data obtained was used for calibration study. The latter was done by training a feed-forward neural network designed for predicting the force vs. wavelength-shift relationship. The experimental results show the designed force sensor design can sense force values in a range of 1N with an average relative error less than 2% of full scale. Ex-vivo tissue palpation experiments were further done on pig liver organs to verify the effectiveness and applicability of the proposed sensor design in minimally invasive surgery.

29 September 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YAYousef Al-handarish
Yousef Al-handarish
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWen ke Duan
Wen ke Duan
JCJing Chen
Jing Chen
LZLuo Zebang
Luo Zebang
Lei WangLei Wang
Lei Wang
Recently, flexible tactile sensors based on three-dimensional (3D) porous conductive composites, endowed with high sensitivity, a wide sensing range, fast response, and the capability to detect low pressures, have aroused considerable attention. These sensors have been employed in different practical domain areas such as artificial skin, healthcare systems, and human–machine interaction. In this study, a facile, cost-efficient method is proposed for fabricating a highly sensitive piezoresistive tactile sensor based on a 3D porous dielectric layer. The proposed sensor is designed with a simple dip-coating homogeneous synergetic conductive network of carbon black (CB) and multi-walled carbon nanotube (MWCNTs) composite on polydimethysiloxane (PDMS) sponge skeletons. The unique combination of a 3D porous structure, with hybrid conductive networks of CB/MWCNTs displayed a superior elasticity, with outstanding electrical characterization under external compression. The piezoresistive tactile sensor exhibited a high sensitivity of (15 kPa−1), with a rapid response time (100 ms), the capability of detecting both large and small compressive strains, as well as excellent mechanical deformability and stability over 1000 cycles. Benefiting from a long-term stability, fast response, and low-detection limit, the piezoresistive sensor was successfully utilized in monitoring human physiological signals, including finger heart rate, pulses, knee bending, respiration, and finger grabbing motions during the process of picking up an object. Furthermore, a comprehensive performance of the sensor was carried out, and the sensor’s design fulfilled vital evaluation metrics, such as low-cost and simplicity in the fabrication process. Thus, 3D porous-based piezoresistive tactile sensors could rapidly promote the development of high-performance flexible sensors, and make them very attractive for an enormous range of potential applications in healthcare devices, wearable electronics, and intelligent robotic systems.

5 May 2021 in Advances in Traditional Medicine
Verified
Journal Article
Closed access
PDF file
JOJoshua Iseoluwa Orege
Joshua Iseoluwa Orege
SASherif Adeyemi
Sherif Adeyemi
Bashir Bolaji TiamiyuBashir Bolaji Tiamiyu
Bashir Bolaji Tiamiyu
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
YIYusuf Ajibola Ibrahim
Yusuf Ajibola Ibrahim
OOOdunola Blessing Orege
Odunola Blessing Orege