Xing-Yu Chen

Xing-Yu Chen

Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, Guangdong, China
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
WDWenke Duan
Wenke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
WDWenjing Du
Wenjing Du
JMJun Ma
Jun Ma
XCXing-Yu Chen
Xing-Yu Chen
Lei WangLei Wang
Lei Wang
Prior methods of patient care have changed in recent years due to the availability of minimally invasive surgical platforms for endovascular interventions. These platforms have demonstrated the ability to improve patients’ vascular intervention outcomes, and global morbidities and mortalities from vascular disease are decreasing. Nonetheless, there are still concerns about the long-term effects of exposing interventionalists and patients to the operational hazards in the cath lab, and the perioperative risks that patients undergo. For these reasons, robot-assisted vascular interventions were developed to provide interventionalists with the ability to perform minimally invasive procedures with improved surgical workflow. We conducted a thorough literature search and presented a review of 130 studies published within the last 20 years that focused on robot-assisted endovascular interventions and are closely related to the current gains and obstacles of vascular interventional robots published up to 2022. We assessed both the research-based prototypes and commercial products, with an emphasis on their technical characteristics and application domains. Furthermore, we outlined how the robotic platforms enhanced both surgeons’ and patients’ perioperative experiences of robot-assisted vascular interventions. Finally, we summarized our findings and proposed three key milestones that could improve the development of the next-generation vascular interventional robots.

1 February 2015 in AIP Advances
Verified
Journal Article
Open access
PDF file
LLLiangliang Liu
Liangliang Liu
ZLZhuo Li
Zhuo Li
BXBingzheng Xu
Bingzheng Xu
CGChangqing Gu
Changqing Gu
CCChen Chen
Chen Chen
XCXing-Yu Chen
Xing-Yu Chen
In this work, we propose an optimized transition structure to realize smooth and high efficiency conversion from the guided wave supported by a conventional rectangular waveguide (CRW) to the domino plasmon polaritons (DPPs) supported by a domino plasmonic waveguide (DPW) and vice versa in the X-band (8.2GHz∼12.4GHz). This transition structure consists of two tapered CRWs connected by a gradient domino array with optimized gradient heights and lateral widths. Experimental results of the S-parameters show excellent agreement with the simulations and the optimization scheme can be readily extended to other bands. Furthermore, a domino plasmonic power divider is implemented to demonstrate the application of the transition structure in the integration of conventional microwave circuits with plasmonic devices.

8 March 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
YDYangyang Du
Yangyang Du
XWXiaojun Wu
Xiaojun Wu
JXJiasheng Xue
Jiasheng Xue
XCXing-Yu Chen
Xing-Yu Chen
CCChongjing Cao
Chongjing Cao
Xing GaoXing Gao
Xing Gao
Confined space searches such as pipeline inspections are widely demanded in various scenarios, where lightweight soft robots with inherent compliance to adapt to unstructured environments exhibit good potential. We proposed a tubular soft robot with a simple structure of a spring-rolled dielectric elastomer (SRDE) and compliant passive bristles. Due to the compliance of the bristles, the proposed robots can work in pipelines with inner diameters both larger and smaller than the one of the bristles. Firstly, the nonlinear dynamic behaviors of the SRDE were investigated experimentally. Then, we fabricated the proposed robot with a bristle diameter of 19 mm and then studied its performance in pipelines on the ground with inner diameters of 18 mm and 20 mm. When the pipeline’s inner diameter was less than the outer diameter of the bristles, the bristles remained in the state of bending and the robot locomotion is mainly due to anisotropic friction (1.88 and 0.88 body lengths per second horizontally and vertically, respectively, in inner diameter of 18 mm and 0.06 body length per second in that of 16 mm). In the case of the pipeline with the larger inner diameter, the bristles were not fully constrained, and a small bending moment applied on the lower bristle legs contributed to the robot’s locomotion, leading to a high velocity (2.78 body lengths per second in 20 mm diameter acrylic pipe). In addition, the robot can work in varying geometries, such as curving pipes (curve radius ranges from 0.11 m to 0.31 m) at around two body lengths per second horizontally and on the ground at 3.52 body lengths per second, showing promise for pipeline or narrow space inspections.

25 December 2023 in IEEE Transactions on Haptics
Verified
Journal Article
Open access
WDWen ke Duan
Wen ke Duan
ZLZihao Li
Zihao Li
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
WDWenjing Du
Wenjing Du
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
Lei WangLei Wang
Lei Wang
Robot-assisted endovascular intervention has the potential to reduce radiation exposure to surgeons and enhance outcomes of interventions. However, the success and safety of endovascular interventions depend on surgeons’ ability to accurately manipulate endovascular tools such as guidewire and catheter and perceive their safety when cannulating patient's vessels. Currently, the existing interventional robots lack a haptic system for accurate force feedback that surgeons can rely on. In this paper, a haptic-enabled endovascular interventional robot was developed. We proposed a dynamic hysteresis compensation model to address the challenges of hysteresis and nonlinearity in magnetic powder brake-based haptic interface, which were used for providing high-precision and higher dynamic range haptic perception. Also, for the first time, a human perceptual-based haptic enhancement model and safety strategy were integrated with the custom-built haptic interface for enhancing sensation discrimination ability during robot-assisted endovascular interventions. This can effectively amplify even subtle changes in low-intensity operational forces such that surgeons can better discern any vessel-tools interaction force. Several experimental studies were performed to show that the haptic interface and the kinesthetic perception enhancement model can enhance the transparency of robot-assisted endovascular interventions, as well as promote the safety awareness of surgeon.

13 December 2022 in Fibers
Verified
Journal Article
Open access
PDF file
XCXing-Yu Chen
Xing-Yu Chen
YCYinan Chen
Yinan Chen
WDWen ke Duan
Wen ke Duan
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
GYGuanlin Yi
Guanlin Yi
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
Interventional therapy is one of the most effective methods for diagnosing and treating vascular-related diseases at present. It relies on achieving precise and safe navigation of intravascular tools within a patient’s vasculature. Vascular Interventional Surgical Robots (VISR) can reduce surgeons’ exposure to operational hazards including radiation. However, the absence of apt position control and force feedback remains a challenge. This study presents an isomorphic master–slave VISR for precise navigation of endovascular tools viz. catheters and guidewires. The master console aids operators in issuing manipulation commands and logs feedback from the force, rotation, and translation data. The slave manipulator uses the commands received from the master platform for actual tool navigation. However, precise master–slave position control and force feedback are precursors for optimal patient outcomes. This study utilized a fuzzy-PID controller for precise tool navigation and a neural network model for resistance force modulation with 50 mN precision. Furthermore, we evaluated the performance of using the learning-based models within our VISR and compared it with the performances from conventional methods. Results show that the models enhanced the proposed robotic system with better navigation precision, faster response speed, and improved force measurement capabilities.

28 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Toluwanimi Oluwadara AkinyemiToluwanimi Oluwadara Akinyemi
Toluwanimi Oluwadara Akinyemi
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
XCXing-Yu Chen
Xing-Yu Chen
WDWen ke Duan
Wen ke Duan
WDWenjing Du
Wenjing Du
Lei WangLei Wang
Lei Wang
Robotic catheter systems with master–slave designs are employed for teleoperated navigation of flexible endovascular tools for treating calcified lesions. Despite improved tool manipulation techniques, patient safety and lowering operative risks remain top priorities. Therefore, minimizing undesirable drifts and imprecise navigation of flexible tools during intravascular catheterization is essential. In the current master–slave designs, finite displacement lag between position command and actual navigation action at the slave device affects smooth catheterization. In this study, we designed and developed a compact 2-DOF robotic catheter system and characterized the influence of displacement step values, velocity, and motion gap on the position error at the slave device. For uniform and varying motion commands from the master platform, the results indicate that the overall position error increases with the distance traveled and the displacement step values, respectively. Hence, we proposed using recurrent neural networks—long short-term memory and gated recurrent unit controllers to predict the slave robot’s position and appropriate compensation value per translation step. An analysis of in-silico studies with CoppeliaSim showed that the neural-based controllers can ensure uniform motion mapping between the master–slave devices. Furthermore, we implemented the models within the RCS for a catheterization length of 120 mm. The result demonstrates that the controllers suitably aid the slave robot’s stepwise displacement. Thus, the neural-based controllers help match the translational motion and precise tool navigation by the slave robotic device. Therefore, the neural-based controllers could contribute to alleviating patients’ safety concerns during robotic interventions.