Claudio Giangrossi

Dr. Claudio Giangrossi

University of Florence, Florence, Tuscany, Italy
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
ADAlessandro Dallai
Alessandro Dallai
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Valentino MeacciValentino Meacci
Valentino Meacci
Piero TortoliPiero Tortoli
Piero Tortoli
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.

14 January 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Enrico BoniEnrico Boni
Enrico Boni
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
PMPaolo Mattesini
Paolo Mattesini
ADAlessandro Dallai
Alessandro Dallai
Piero TortoliPiero Tortoli
Piero Tortoli
2-D sparse arrays may push the development of low-cost 3-D systems, not needing to control thousands of elements by expensive application-specific integrated circuits. However, there is still some concern about their suitability in applications, such as Doppler investigation, which inherently involve poor signal-to-noise ratios (SNRs). In this paper, a novel real-time 3-D pulsed-wave Doppler system, based on a 256-element 2-D spiral array, is presented. Coded transmission and matched filtering were implemented to improve the system SNR. Standard sonograms as well as multigate spectral Doppler (MSD) profiles, along lines that can be arbitrarily located in different planes, are presented. The performance of the system was assessed quantitatively on experimental data obtained from a straight tube flow phantom. An SNR increase of 11.4 dB was measured by transmitting linear chirps instead of standard sinusoidal bursts. For a qualitative assessment of the system performance in more realistic conditions, an anthropomorphic phantom of the carotid arteries was used. Finally, real-time B-mode and MSD images were obtained from healthy volunteers.

19 August 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Valentino MeacciValentino Meacci
Valentino Meacci
Stefano RicciStefano Ricci
Stefano Ricci
RMRiccardo Matera
Riccardo Matera
Enrico BoniEnrico Boni
Enrico Boni
Piero TortoliPiero Tortoli
Piero Tortoli
The recent development of high-frame-rate (HFR) imaging/Doppler methods based on the transmission of plane or diverging waves, has proposed new challenges to echographic data management and display. Due to the huge amount of data that need to be processed at very high speed, the pulse repetition frequency (PRF) is typically limited to hundreds Hz or few kHz. In Doppler applications, a PRF limitation may result unacceptable since it inherently translates to a corresponding limitation in the maximum detectable velocity. In this paper, the ULA-OP 256 implementation of a novel ultrasound modality, called virtual real-time (VRT), is described. First, for a given HFR real-time modality, the scanner displays the processed results while saving channel data into an internal buffer. Then, ULA-OP 256 switches to VRT mode, according to which the raw data stored in the buffer are immediately re-processed by the same hardware used in real-time. In the two phases, the ULA-OP 256 calculation power can be differently distributed to increase the acquisition frame rate or the quality of processing results. VRT was here used to extend the PRF limit in a multi-line vector Doppler application. In real-time, the PRF was maximized at the expense of the display quality; in VRT, data were reprocessed at a lower rate in a high-quality display format, which provides more detailed flow information. Experiments are reported in which the multi-line vector Doppler technique is shown capable of working at 16 kHz PRF, so that flow jet velocities higher up to 3 m/s can be detected.

4 October 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
GBGiulio Bonciani
Giulio Bonciani
FGFrancesco Guidi
Francesco Guidi
Piero TortoliPiero Tortoli
Piero Tortoli
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
ADAlessandro Dallai
Alessandro Dallai
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
Ultrasound open scanners have recently boosted the development and validation of novel imaging techniques. They are usually split into hardware- or software-oriented systems, depending on whether they process the echo data using embedded FPGAs/DSPs or a GPU on a host PC. The goal of this work was to realize a high-performance heterogeneous open scanner capable of leveraging the strengths of both hardware and software-oriented systems. The elaboration power of the 256-channel ultrasound advanced open platform (ULA-OP 256) was further enhanced by embedding a compact co-processing GPU system-on-module (SoM). By carefully avoiding latencies and overheads through low-level optimization work, an efficient PCIe communication interface was established between the GPU and the processing devices onboard the ULA-OP 256. As a proof of concept of the enhanced system, the high frame rate color flow mapping technique was implemented on the GPU SoM and tested. Compared to a previous DSP-based implementation, higher real-time frame rates were achieved together with unprecedented flexibility in setting crucial parameters such as the ensemble length (EL). For example, by setting EL=64 and a continuous-time high-pass filter, the flow was investigated with high temporal and spatial resolution in the femoral vein bifurcation (frame rate = 1.1 kHz) and carotid artery bulb (4.3 kHz), highlighting the flow disturbances due to valve aperture and secondary velocity components, respectively. The results of this work promote the development of other computational-expensive processing algorithms in real-time and may inspire the next generation of ultrasound high-performance heterogeneous scanners.

7 July 2025 in Ultrasound in Medicine & Biology
Verified
Journal Article
Open access
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
FGFrancesco Guidi
Francesco Guidi
ENEmile Noothout
Emile Noothout
LWLuxi Wei
Luxi Wei
PTPiero Tortoli
Piero Tortoli
The assessment of blood-flow volume (BFV) is clinically relevant for the diagnosis and monitoring of cardiovascular dysfunctions and the prevention of subsequent secondary diseases. Non-invasive BFV measurement based on ultrasound methods are appealing for lower cost, real-time operation, and equipment portability. Recently, complex ultrasound research scanners with 1024 channels controlling the elements of a 2-D matrix array probe, have been demonstrated suitable for off-line accurate BFV estimates. In this work, a streamlined approach, using a 256-channel research scanner paired with a 256-element 2-D sparse spiral array, is proposed and validated. This setup allows for simultaneous scanning of the vessel's longitudinal and transverse sections through an interleaved transmission sequence. In real-time, the longitudinal scan is used to determine the flow direction, while the transverse scan captures both the dynamic cross-sectional area and the local velocities by high frame rate color flow mapping. Flow phantom experiments under steady and pulsatile flow conditions were conducted to assess the performance by comparing the measurements with the outputs of a reference flow sensor. The proposed method provided accurate and precise BFV values for both flow conditions, with mean percentage error and standard deviation always lower than 9.4% and 2.8%, respectively. Furthermore, preliminary in vivo experiments have produced results consistent with those reported in the literature. The proposed method based on the use of a sparse array has permitted accurate and precise phantom BFV measurements and has been shown suitable for real-time arterial BFV measurements.

11 September 2021
Verified
Conference Paper
Closed access
FGFrancesco Guidi
Francesco Guidi
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
ADAlessandro Dallai
Alessandro Dallai
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
PTPiero Tortoli
Piero Tortoli
The transmission of plane waves and parallel beamforming have been successfully used to improve the performance of Colour Flow Mapping (CFM) systems, as they allow the exploitation of effective wall filters in continuous time and autocorrelations with very long ensemble lengths. However, although hundreds of colour maps could be produced in realtime, the computing power requirements still compromise either the frame-rate, the region of interest (ROI) size or the spatial resolution. In this paper, the combination of real-time PW CFM @ 250 frames/sec with the virtual real-time modality of ULA-OP 256, is shown ideal for the investigation of rapidly changing flow at improved spatial resolution and extended ROI size.