Valentino Meacci

Dr. Valentino Meacci


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 October 2018 in Electronics
Verified
Journal Article
Open access
PDF file
Stefano RicciStefano Ricci
Stefano Ricci
Valentino MeacciValentino Meacci
Valentino Meacci
Stepper motors are employed in a wide range of consumer and industrial applications. Their use is simple: a digital device generates pulse-bursts and a direction bit towards a power driver that produces the 2-phase currents feeding the motor windings. Despite its simplicity, this open-loop approach fails if the torque load exceeds the motor capacity, so the motor and driver should be oversized at the expense of efficiency and cost. Field-Oriented closed-loop Control (FOC) solves the problem, and the recent availability of low cost electronics devices like Digital Signal Processors, Field Programmable Gate Arrays (FPGA), or even Microcontrollers with dedicated peripherals, fostered the investigation and implementation of several variants of the FOC method. In this paper, a simple and economic FOC torque control method for hybrid stepper motors is presented. The load angle is corrected accordingly to the actual shaft position through pulse-bursts and direction commands issued towards a commercial stepper driver, which manages the 2-phase winding currents. Thanks to the FPGA implementation, the control loop updates the electrical position every 50 μs only, thus allowing a load angle accuracy of −1/100 rad for a rotor velocity up to 750 rev/min, as shown in the reported experiments.

14 December 2018 in Electronics
Verified
Journal Article
Open access
PDF file
Stefano RicciStefano Ricci
Stefano Ricci
Valentino MeacciValentino Meacci
Valentino Meacci
Pulse-Wave Doppler (PWD) ultrasound has been applied to the detection of blood flow for a long time; recently the same method was also proven effective in the monitoring of industrial fluids and suspensions flowing in pipes. In a PWD investigation, bursts of ultrasounds at 0.5–10 MHz are periodically transmitted in the medium under test. The received signal is amplified, sampled at tens of MHz, and digitally processed in a Field Programmable Gate Array (FPGA). First processing step is a coherent demodulation. Unfortunately, the weak echoes reflected from the fluid particles are received together with the echoes from the high-reflective pipe walls, whose amplitude can be 30–40 dB higher. This represents a challenge for the input dynamics of the system and the demodulator, which should clearly detect the weak fluid signal while not saturating at the pipe wall components. In this paper, a numerical demodulator architecture is presented capable of auto-tuning its internal dynamics to adapt to the feature of the actual input signal. The proposed demodulator is integrated into a system for the detection of the velocity profile of fluids flowing in pipes. Simulations and experiments with the system connected to a flow-rig show that the data-adaptive demodulator produces a noise reduction of at least of 20 dB with respect to different approaches, and recovers a correct velocity profile even when the input data are sampled at 8 bits only instead of the typical 12–16 bits.

28 June 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
ADAlessandro Dallai
Alessandro Dallai
Daniele MazierliDaniele Mazierli
Daniele Mazierli
Valentino MeacciValentino Meacci
Valentino Meacci
Piero TortoliPiero Tortoli
Piero Tortoli
The spread of high frame rate and 3-D imaging techniques has raised pressing requirements for ultrasound systems. In particular, the processing power and data transfer rate requirements may be so demanding to hinder the real-time (RT) implementation of such techniques. This paper first analyzes the general requirements involved in RT ultrasound systems. Then, it identifies the main bottlenecks in the receiving section of a specific RT scanner, the ULA-OP 256, which is one of the most powerful available open scanners and may therefore be assumed as a reference. This case study has evidenced that the “star” topology, used to digitally interconnect the system’s boards, may easily saturate the data transfer bandwidth, thus impacting the achievable frame/volume rates in RT. The architecture of the digital scanner was exploited to tackle the bottlenecks by enabling a new “ring“ communication topology. Experimental 2-D and 3-D high-frame-rate imaging tests were conducted to evaluate the frame rates achievable with both interconnection modalities. It is shown that the ring topology enables up to 4400 frames/s and 510 volumes/s, with mean increments of +230% (up to +620%) compared to the star topology.

10 November 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MOMarta Orlowska
Marta Orlowska
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
SBStephanie Bezy
Stephanie Bezy
Valentino MeacciValentino Meacci
Valentino Meacci
JVJens-Uwe Voigt
Jens-Uwe Voigt
JDJan D'Hooge
Jan D'Hooge
High frame rate (HFR) speckle tracking echocardiography (STE) assesses myocardial function by quantifying motion and deformation at high temporal resolution. Among the proposed HFR techniques, Multi-Line Transmission (MLT) and Diverging Wave (DW) imaging have been used in this context both being characterized by specific advantages and disadvantages. Therefore, in this paper, we directly contrast both approaches in an in-vivo setting while operating at the same frame rate. First, images were recorded at baseline (resting condition) from healthy volunteers and patients. Next, additional acquisitions during stress echocardiography were performed on volunteers. Each scan was contoured and processed by a previously proposed 2D HFR STE algorithm based on cross-correlation. Then, strain curves and their end-systolic (ES) values were extracted for all myocardial segments for further statistical analysis. The baseline acquisitions did not reveal differences in estimated strain between the acquisition modes (p>0.35); myocardial segments (p>0.3) nor an interaction between imaging mode and depth (p>0.87). Similarly, during stress testing, no difference (p=0.7) was observed for the two scan sequences, stress levels nor an interaction sequence-stress level (p=0.94). Overall, our findings show that MLT and DW compounding give comparable HFR STE strain values and that the choice for using one method or the other may thus rather be based on other factors, e.g. system requirements or computational cost.

11 May 2019
Verified
Book Chapter
Closed access
PDF file
Valentino MeacciValentino Meacci
Valentino Meacci
Enrico BoniEnrico Boni
Enrico Boni
ADAlessandro Dallai
Alessandro Dallai
Alessandro RamalliAlessandro Ramalli
Alessandro Ramalli
MSMonica Scaringella
Monica Scaringella
SRStefano Ricci
Stefano Ricci

19 August 2020 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
Claudio GiangrossiClaudio Giangrossi
Claudio Giangrossi
Valentino MeacciValentino Meacci
Valentino Meacci
Stefano RicciStefano Ricci
Stefano Ricci
RMRiccardo Matera
Riccardo Matera
Enrico BoniEnrico Boni
Enrico Boni
Piero TortoliPiero Tortoli
Piero Tortoli
The recent development of high-frame-rate (HFR) imaging/Doppler methods based on the transmission of plane or diverging waves, has proposed new challenges to echographic data management and display. Due to the huge amount of data that need to be processed at very high speed, the pulse repetition frequency (PRF) is typically limited to hundreds Hz or few kHz. In Doppler applications, a PRF limitation may result unacceptable since it inherently translates to a corresponding limitation in the maximum detectable velocity. In this paper, the ULA-OP 256 implementation of a novel ultrasound modality, called virtual real-time (VRT), is described. First, for a given HFR real-time modality, the scanner displays the processed results while saving channel data into an internal buffer. Then, ULA-OP 256 switches to VRT mode, according to which the raw data stored in the buffer are immediately re-processed by the same hardware used in real-time. In the two phases, the ULA-OP 256 calculation power can be differently distributed to increase the acquisition frame rate or the quality of processing results. VRT was here used to extend the PRF limit in a multi-line vector Doppler application. In real-time, the PRF was maximized at the expense of the display quality; in VRT, data were reprocessed at a lower rate in a high-quality display format, which provides more detailed flow information. Experiments are reported in which the multi-line vector Doppler technique is shown capable of working at 16 kHz PRF, so that flow jet velocities higher up to 3 m/s can be detected.