The aim of this study is to propose a test method for the determination of the quality of transformer paper insulation. For this purpose, the oil/cellulose insulation systems were exposed to various accelerated aging tests. The results of the aging experiments of normal Kraft and thermally upgraded papers, two different types of transformer oil (mineral and natural ester), and copper are shown. Aging was carried out in various experiments at 150 °C, 160 °C, 170 °C, and 180 °C with dry (initial values ≤ 0.5%) and moistened cellulose insulation (initial values 3–3.5%). Following insulating oil and paper, degradation markers were measured: the degree of polymerization, tensile strength, furan derivates, methanol/ethanol, acidity, interfacial tension, and dissipation factor. It was found that the aging of cellulose insulation in cycles was 1.5–1.6 times faster in comparison to continuous aging, due to the more pronounced effect of hydrolytic mechanism in cyclic aging owing to the produced and absorbed water. Furthermore, it was observed that the high initial water content in cellulose increases the aging rate two to three times more than in the dry experimental setup. The proposed aging test in cycles can be used to achieve faster aging and to compare the quality of different insulating papers.
This article presents a method for quantification of methanol and ethanol integrated in the same gas-chromatographic run with a quantification of gases dissolved in mineral oil, making it an integrated tool in transformer diagnostics. The results of aging experiments at 120 °C and 60 °C of Kraft paper, copper, barrier, and pressboard immersed in mineral oil, as well as the aging of thermal upgrade paper in mineral and natural ester oil at 140 °C are presented, in order to investigate correlations between different aging markers and to evaluate their partitioning between oil and cellulose at defined conditions. The results of partitioning experiments at 60 °C showed that re-absorption of methanol from oil to the cellulose materials is faster than the re-absorption of furans. This means that methanol is a paper-degradation marker that can be used in diagnostics over shorter equilibrium times and for the detection of developing faults at broader temperature ranges. Furthermore, a statistical overview of methanol concentration from a database and two transformer fault diagnostic cases are presented. Therefore, in addition to an analysis of gases dissolved in oil, the use of methanol and ethanol in transformer fault and failure investigations should be explored and verified through transformer fault investigations and postmortem analyses.
28 March 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Corrosive sulfur compounds in mineral insulating oils can easily react with metal surfaces in power transformers and form deposits, which can further cause failures of the electrical equipment. Copper sulfide formation has been well studied over the last couple of decades. However, silver sulfide formation also requires attention, due to significant number of failures of on-load tap changers caused by silver corrosion reported worldwide from different utilities. The conventional silver corrosion tests (DIN 51353 and ASTM D1275-15) do not provide adequate assessment of oil corrosivity against silver, even if the oil contains dibenzyl disulfide (DBDS) and other reactive sulfur compounds (disulfides and mercaptans) in high concentrations. The new testing method for silver corrosion has been performed on a significant portion of oils containing DBDS, as major reactive sulfur compound, which remained “non-corrosive” following the ASTM D1275-15 silver strip test. The method was demonstrated on five oils from free-breathing power transformers in service, containing DBDS in a wide range of concentrations (from approx. 40 to 200 mg/kg of DBDS). The new method comprises of a modification to the ASTM D 1275-15 test set up, by introducing longer test duration times and continuous oxygen ingress, which was found to be the most crucial parameter for promoting the formation of silver sulfide deposits. This was confirmed by EDX results, showing an increased sulfur weight percentage on silver strip after the test. The application of the modified ASTM silver corrosion test will contribute to improving the assessment of sulfur corrosion risk.
1 January 2022 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
The Republic of Serbia signed and ratified the Stockholm Convention on Persistent Organic Pollutants. Law on ratification of the Stockholm Convention was adopted and actions were defined through the National Implementation Plan and the Action Plan. On their basis Project Proper Management and Final Disposal of Polychlorinated Biphenyls (PCBs) was created. Institute Nikola Tesla (INT) participated in the realization of the project. In the period from 2015 to 2022, 601 tons of PCB oil was successfully decontaminated by the INT mobile plant, i.e. the PCB content was below 50 mg/kg, which classified the power transformers (PT) as non-contaminated [1,2]. If PT becomes waste or in case of necessary repair or oil regeneration, the required limit value is 10 mg/kg. According to data from INT database there are still 2637 PTs containing PCBs in the concentration range of 2 to 50 mg/kg. In this paper application of the environmentally closed INT decontamination technology for achieving low values of PCB in the oil is shown.
1 January 2024 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
The project funded by the Science Fund of the Republic of Serbia, Development of Green Technology to Mitigate Power Transformer Failures Induced by Elemental Sulphur and Change Current Hazardous Practice in Transformer Oil Regeneration, under the acronym GreenCleanS focuses on developing a new technology for removing elemental sulphur molecule (S₈) from mineral insulating oils used in power transformers (PT) utilization an innovative low-temperature desulfurization process. The technology development includes experimental work at the laboratory scale and pilot scale level (technology readiness level, TRL 4), as well as the demonstration of the technology in an operational environment, involving the treatment of 3 tons of oil in a mobile desulfurization unit to achieve TRL 7. The implementation of this innovative technology will contribute to reducing the number of transformer failures caused by mineral oils containing S₈, a highly corrosive compound.