Valentina Engineering Institute Nikola Vasovic

Dr. Valentina Engineering Institute Nikola Vasovic

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
DMDraginja Mihajlovic
Draginja Mihajlovic
BPBranko Pejovic
Branko Pejovic
MMMilovan Milovanovic
Milovan Milovanovic
Zoran RadakovićZoran Radaković
Zoran Radaković

1 June 2023 in Polymers
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
The aim of this study is to propose a test method for the determination of the quality of transformer paper insulation. For this purpose, the oil/cellulose insulation systems were exposed to various accelerated aging tests. The results of the aging experiments of normal Kraft and thermally upgraded papers, two different types of transformer oil (mineral and natural ester), and copper are shown. Aging was carried out in various experiments at 150 °C, 160 °C, 170 °C, and 180 °C with dry (initial values ≤ 0.5%) and moistened cellulose insulation (initial values 3–3.5%). Following insulating oil and paper, degradation markers were measured: the degree of polymerization, tensile strength, furan derivates, methanol/ethanol, acidity, interfacial tension, and dissipation factor. It was found that the aging of cellulose insulation in cycles was 1.5–1.6 times faster in comparison to continuous aging, due to the more pronounced effect of hydrolytic mechanism in cyclic aging owing to the produced and absorbed water. Furthermore, it was observed that the high initial water content in cellulose increases the aging rate two to three times more than in the dry experimental setup. The proposed aging test in cycles can be used to achieve faster aging and to compare the quality of different insulating papers.

4 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
VIVladimir Ivancevic
Vladimir Ivancevic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
This article presents a method for quantification of methanol and ethanol integrated in the same gas-chromatographic run with a quantification of gases dissolved in mineral oil, making it an integrated tool in transformer diagnostics. The results of aging experiments at 120 °C and 60 °C of Kraft paper, copper, barrier, and pressboard immersed in mineral oil, as well as the aging of thermal upgrade paper in mineral and natural ester oil at 140 °C are presented, in order to investigate correlations between different aging markers and to evaluate their partitioning between oil and cellulose at defined conditions. The results of partitioning experiments at 60 °C showed that re-absorption of methanol from oil to the cellulose materials is faster than the re-absorption of furans. This means that methanol is a paper-degradation marker that can be used in diagnostics over shorter equilibrium times and for the detection of developing faults at broader temperature ranges. Furthermore, a statistical overview of methanol concentration from a database and two transformer fault diagnostic cases are presented. Therefore, in addition to an analysis of gases dissolved in oil, the use of methanol and ethanol in transformer fault and failure investigations should be explored and verified through transformer fault investigations and postmortem analyses.

1 January 2019 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
DMDraginja Mihajlović
Draginja Mihajlović
JJJelena Janković
Jelena Janković
JLJelena Lukić
Jelena Lukić
The reliability of power transformers operation largely depends on the insulation system condition, especially on the condition of paper insulation. Determining the condition of paper insulation of transformers in use cannot be made by direct measurements. The most common way of assessing the paper insulation condition is by analyzing the content of 2-furfural dissolved in the insulating oil and by applying correlations between the degree of paper polymerization and the 2-furfural content in the insulating oil. The concentration of 2-furfural in the oil depends on the moisture content of the insulation system and the oxygen and acid content in the oil. In order to gain a better insight into the cumulative content of 2-furfural produced by paper degradation, excluding changes in the 2-furfural content caused by migration between paper and oil at different operating temperatures, dependence of the degree of polymerization of kraft paper to 2-FAL content in the oil, corrected to a reference temperature of 20°C, for a moisture content in cellulose of 1-1.5% and 3-4% is presented in this paper. This diagram has been verified on 4 transformers according to available data from the database of the Electrical Engineering Institute Nikola Tesla. In the future, this diagram should be completed for moisture content of 2.5% in cellulose insulation.

1 January 2022 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
JJJelena Jankovic
Jelena Jankovic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
VIVladimir Ivančević
Vladimir Ivančević
JLJelena Lukic
Jelena Lukic
The Republic of Serbia signed and ratified the Stockholm Convention on Persistent Organic Pollutants. Law on ratification of the Stockholm Convention was adopted and actions were defined through the National Implementation Plan and the Action Plan. On their basis Project Proper Management and Final Disposal of Polychlorinated Biphenyls (PCBs) was created. Institute Nikola Tesla (INT) participated in the realization of the project. In the period from 2015 to 2022, 601 tons of PCB oil was successfully decontaminated by the INT mobile plant, i.e. the PCB content was below 50 mg/kg, which classified the power transformers (PT) as non-contaminated [1,2]. If PT becomes waste or in case of necessary repair or oil regeneration, the required limit value is 10 mg/kg. According to data from INT database there are still 2637 PTs containing PCBs in the concentration range of 2 to 50 mg/kg. In this paper application of the environmentally closed INT decontamination technology for achieving low values of PCB in the oil is shown.

1 January 2024 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
URUros Radoman
Uros Radoman
FKFilip Kilibarda
Filip Kilibarda
NKNenad Kartalović
Nenad Kartalović
NMNikola Miladinovic
Nikola Miladinovic
VPVladimir Polužanski
Vladimir Polužanski
JLJelena Lukic
Jelena Lukic
This paper provides a literature review and establishes the state-of-the-art in the concept and application of Digital Twin (DT) technology to power transformers. The introductory sections focus on the evolving definition and universal concepts of DT, independent of specific fields of application, as well as the goals of Industry 4.0 and the technologies that enable digital transformation in industry. Special attention is given to the particularities of the power industry, with an emphasis on the unique requirements posed by the nature and importance of oil-filled power transformers, which serve as the foundation for the development of systems based on DT technologies.