Dejan Kolarski

Mr. Dejan Kolarski

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
JJJelena Jankovic
Jelena Jankovic
JLJelena Lukic
Jelena Lukic
DKDejan Kolarski
Dejan Kolarski
DVDjordje Veljovic
Djordje Veljovic
Željko RadovanovićŽeljko Radovanović
Željko Radovanović
SDSilvana Dimitrijevic
Silvana Dimitrijevic
Elemental sulfur (S8) is a corrosive sulfur compound which was found to be extremely reactive to silver, causing intensive silver sulfide (Ag2S) deposition on on-load tap changer (OLTC) contacts in power transformers. A highly selective adsorbent (HSA), called Tesla’Ssorb, for the removal of S8 from mineral insulating oils was prepared from raw material (RM) using the novel procedure. In this study, the adsorption properties of HSA for the removal of S8 from the oil were determined. RM and HSA were characterized using various techniques, such as field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX), and X-ray diffraction (XRD). The performance of HSA was determined by adsorption equilibrium, thermodynamic, and kinetic study through batch experiments, at various temperatures and initial concentrations of S8. The obtained results were analyzed by Langmuir and Freundlich adsorption isotherms and it was found that equilibrium data were fitted better with the Langmuir isotherm model. The maximum adsorption capacity was 4.84 mg of S8/g of HSA at 353 K. Thermodynamic parameters, such as enthalpy (ΔH°), Gibbs free energy (ΔG°), and entropy (ΔS°), were calculated and it was found that the sorption process was spontaneous (ΔG° < 0) and endothermic in nature (ΔH° > 0). It was found that the adsorption of S8 follows pseudo-second-order kinetic model, and the activation energy indicated the activated chemisorption process.

12 August 2025 in Materials
Verified
Journal Article
Open access
PDF file
DKDejan Kolarski
Dejan Kolarski
JLJelena Lukic
Jelena Lukic
JJJelena Jankovic
Jelena Jankovic
Sandra GlisicSandra Glisic
Sandra Glisic
Elemental sulfur (S8) reacts readily with silver, forming highly conductive silver sulfide on silver-coated components of on-load tap changers (OLTCs), forming a highly conductive silver sulfide film at the surface of an OLTC, which can lead to the failure of critical components in power transformers. This study investigates the reaction between metallic silver and elemental sulfur dissolved in mineral insulating oil across temperatures from 60 °C to 180 °C. The process involves three stages: the diffusion of sulfur through oil, surface reaction, and product diffusion. For low-viscosity oil, diffusion is not the limiting factor, and sulfur does not react immediately on the silver’s surface, suggesting possible adsorption or intermediate formation. A kinetic analysis revealed that the reaction follows first-order kinetics, with a change in mechanism above 150 °C. The reaction follows the Arrhenius equation in two separate regions: 60–150 °C and 150–180 °C. Activation energy was calculated as 23.67 kJ mol−1, and it can be concluded that the reaction is controlled by the diffusion of sulfur through mineral oil, and at higher temperatures (150 °C to 180 °C), the calculated activation energy is 160.69 kJ mol−1, which leads to the conclusion that the combined chemisorption and diffusion through a silver sulfide–oil interface becomes the new limiting factor.

1 January 2025 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
MDMilica Djukic
Milica Djukic
JLJelena Lukic
Jelena Lukic
JJJelena Jankovic
Jelena Jankovic
DKDejan Kolarski
Dejan Kolarski
For decades, the problem of corrosive sulfur was considered to be exclusively associated with mineral oils. However, recent cases from industry have disproved this assumption. The presence of elemental sulfur in insulating oil causes corrosion of silver contacts and consequently leads to power transformer failures. The aim of this study is to determine the kinetics of the reaction between elemental sulfur and silver in synthetic ester within the temperature range of 120–180 °C. The elemental sulfur content in the oil during the reaction is determined using gas chromatography with an electron capture detector (GC-ECD). The results show that the reaction between silver and elemental sulfur follows the first-order law. A comparative analysis of the examined reaction in synthetic ester and mineral oil shows that the reaction proceeds faster in synthetic ester.

1 January 2025
Verified
Conference Paper
Closed access
JLJelena Lukić
Jelena Lukić
DMDraginja Mihajlovic
Draginja Mihajlovic
JJJelena Jankovic
Jelena Jankovic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
VIVladimir Ivančević
Vladimir Ivančević
NKNeda Kovačević
Neda Kovačević
Focus of 3PINT project is to upgrade readiness level of the innovative technology for the removal of corrosive sulphur, PCB and aging product from transformer oils. Technology itself includes chemical conversion process to refine transformer oils in eco-friendly manner. Used technology is environmentally closed with no toxic emissions and waste released into environment. In addition, innovative solution for corroded silver-plated contacts cleaning, effectively removes silver sulphide deposits from OLTC contacts, ensuring long-term reliability and complete power transformer corrosive sulphur mitigation.

1 January 2021 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
DKDejan Kolarski
Dejan Kolarski
JJJelena Jankovic
Jelena Jankovic
DMDraginja Mihajlović
Draginja Mihajlović
NKNeda Kovačević
Neda Kovačević
JLJelena Lukić
Jelena Lukić
Most power transformer failures are associated with the presence of corrosive sulfur compounds in mineral insulating oil, of which dibenzyl disulfide (DBDS) is the best known and most widespread corrosive sulfur compound. The oil of failed transformers usually contained DBDS, a compound with a pronounced affinity for the formation of copper (I) sulfide (Cu2S). Copper (I) sulfide is a compound that does not dissolve in oil, conducts electricity, and can be deposited on the paper insulation or copper conductor of the transformer. Created conductive paths between the windings can initiate turn-to-turn breakdown and failure of the transformer. Several technological procedures have been developed as a solution to oil corrosivity. The application of desulfurization technology developed by the Electrical Engineering Institute "Nikola Tesla" enables the efficient removal of DBDS and aging products from mineral insulation oils.

16 July 2025 in IEEE Access
Verified
Journal Article
Open access
DKDejan Kolarski
Dejan Kolarski
JLJ. M. Lukic
J. M. Lukic
JJJelena Jankovic
Jelena Jankovic
Sandra GlisicSandra Glisic
Sandra Glisic
AOA. M. Orlović
A. M. Orlović
The presence of corrosive sulfur and polychlorinated biphenyls (PCBs) in mineral insulating oils poses significant challenge to the reliability of power transformers and presents serious environmental risks. Elemental sulfur (S8) and dibenzyl disulfide (DBDS) are well-known for causing the formation of metal sulfides on transformer components, leading to equipment failures, while PCBs present in insulating oils are persistent environmental pollutants with long-term health hazards. Current insulating oil purification techniques, including adsorbents, metal passivators and reagents, exhibit limited effectiveness, particularly if elemental sulfur is present in oil. This study introduces a novel reagent-based desulfurization process which uses copper deposited on iron particles dispersed in polyethylene glycol, for the complete removal of S8 from mineral insulating oil. The integration of S8 removal process with the KOH/PEG complex enables the simultaneous removal of S8, DBDS, and PCBs, with no residual metal particles detected in the oil following the treatment. Laboratory-scale experiments have shown the high efficiency of the developed process resulting in the improved physical-chemical and electrical properties of the oil, which was further verified on pilot scale unit and finally on the industrial scale process unit.