Elemental sulfur (S8) is a corrosive sulfur compound which was found to be extremely reactive to silver, causing intensive silver sulfide (Ag2S) deposition on on-load tap changer (OLTC) contacts in power transformers. A highly selective adsorbent (HSA), called Tesla’Ssorb, for the removal of S8 from mineral insulating oils was prepared from raw material (RM) using the novel procedure. In this study, the adsorption properties of HSA for the removal of S8 from the oil were determined. RM and HSA were characterized using various techniques, such as field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX), and X-ray diffraction (XRD). The performance of HSA was determined by adsorption equilibrium, thermodynamic, and kinetic study through batch experiments, at various temperatures and initial concentrations of S8. The obtained results were analyzed by Langmuir and Freundlich adsorption isotherms and it was found that equilibrium data were fitted better with the Langmuir isotherm model. The maximum adsorption capacity was 4.84 mg of S8/g of HSA at 353 K. Thermodynamic parameters, such as enthalpy (ΔH°), Gibbs free energy (ΔG°), and entropy (ΔS°), were calculated and it was found that the sorption process was spontaneous (ΔG° < 0) and endothermic in nature (ΔH° > 0). It was found that the adsorption of S8 follows pseudo-second-order kinetic model, and the activation energy indicated the activated chemisorption process.

2 February 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JJJelena Jankovic
Jelena Jankovic
JLJelena Lukic
Jelena Lukic
JPJelena Planojevic
Jelena Planojevic
DKDejan Kolarski
Dejan Kolarski
DJDjordje Janackovic
Djordje Janackovic
The presence of corrosive sulfur in the oil increases the risks of power transformer failures. This is very pronounced in the case of the presence of elemental sulfur (S 8 ) in the oil a compound found to be highly reactive to metals, especially to silver at lower operating temperatures causing formation of conductive silver sulfide deposits on the contacts of on-load tap changers. Highly selective adsorbent (HSA) as new mesoporous material is synthesized in the novel procedure to be applied in the removal of corrosive sulfur compounds from the oil. The removal of corrosive sulfur compounds by HSA is obtained by chemical reaction, i.e., chemisorption. The procedure for the preparation of HSA consists of deposition of silver ions on the silicon dioxide support. Both compounds added in well-defined and optimal concentration range are necessary to produce adsorbent of high efficiency in the removal of S 8 and other corrosive sulfur compounds and to obtain good oil properties after treatment. HSA is characterized by nitrogen adsorption–desorption isotherms to define specific surface area, particle size distribution, and porosity. Since the efficiency of conventional adsorbents is found to be lowest in the case of elemental sulfur, among all corrosive sulfur compounds, the efficiency of HSA application in the removal of S 8 is verified on lab-scale system, pilot-scale system, and on-site oil treatment on 35-kV power transformer. Adsorption kinetic study is performed in order to better understand the mechanism of sorption process and potential rate-controlling steps. The pseudo-second-order model adequately fits the S 8 kinetic data confirming that chemisorption is the rate-limiting step.

12 August 2025 in Materials
Verified
Journal Article
Open access
PDF file
DKDejan Kolarski
Dejan Kolarski
JLJelena Lukic
Jelena Lukic
JJJelena Jankovic
Jelena Jankovic
Sandra GlisicSandra Glisic
Sandra Glisic
Elemental sulfur (S8) reacts readily with silver, forming highly conductive silver sulfide on silver-coated components of on-load tap changers (OLTCs), forming a highly conductive silver sulfide film at the surface of an OLTC, which can lead to the failure of critical components in power transformers. This study investigates the reaction between metallic silver and elemental sulfur dissolved in mineral insulating oil across temperatures from 60 °C to 180 °C. The process involves three stages: the diffusion of sulfur through oil, surface reaction, and product diffusion. For low-viscosity oil, diffusion is not the limiting factor, and sulfur does not react immediately on the silver’s surface, suggesting possible adsorption or intermediate formation. A kinetic analysis revealed that the reaction follows first-order kinetics, with a change in mechanism above 150 °C. The reaction follows the Arrhenius equation in two separate regions: 60–150 °C and 150–180 °C. Activation energy was calculated as 23.67 kJ mol−1, and it can be concluded that the reaction is controlled by the diffusion of sulfur through mineral oil, and at higher temperatures (150 °C to 180 °C), the calculated activation energy is 160.69 kJ mol−1, which leads to the conclusion that the combined chemisorption and diffusion through a silver sulfide–oil interface becomes the new limiting factor.

1 January 2018 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
JJJelena Jankovic
Jelena Jankovic
DMDraginja Mihajlović
Draginja Mihajlović
NKNeda Kovačević
Neda Kovačević
VVValentina Vasović
Valentina Vasović
JLJelena Lukić
Jelena Lukić
The exploitation of PCB contaminated power transformers and those which contain corrosive sulphur is related to the greatest risks to the environment, due to possible environmental accidents and faults and failures of transformers. The equipment contaminated with PCB require special attention, more frequent testing of transformer condition and control of oil leaking, while for corrosive oils standards and requirements defined in CIGRE TB 378, CIGRE TB 625, IEC 60296 and IEC 60422 are restrictive for the use of corrosive oils. Overview of the problems with PCB contaminated equipment and corrosive sulphur is provided in accordance to the latest knowledge in these areas. PCB decontamination, desulfurization and oil regeneration process is described by the application of patented technology developed in the 'Nikola Tesla' Institute. Summarized results of decontamination process of 310 PCB contaminated power transformers with different voltage levels and power and removal of corrosive sulphur from 29 transformers show the efficiency of this process for simultaneous removal of PCB, corrosive sulphur and oil ageing products.

28 March 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JJJelena Jankovic
Jelena Jankovic
JLJelena Lukic
Jelena Lukic
DMDraginja Mihajlovic
Draginja Mihajlovic
MFMarc Foata
Marc Foata
BMBarry Myburgh
Barry Myburgh
Corrosive sulfur compounds in mineral insulating oils can easily react with metal surfaces in power transformers and form deposits, which can further cause failures of the electrical equipment. Copper sulfide formation has been well studied over the last couple of decades. However, silver sulfide formation also requires attention, due to significant number of failures of on-load tap changers caused by silver corrosion reported worldwide from different utilities. The conventional silver corrosion tests (DIN 51353 and ASTM D1275-15) do not provide adequate assessment of oil corrosivity against silver, even if the oil contains dibenzyl disulfide (DBDS) and other reactive sulfur compounds (disulfides and mercaptans) in high concentrations. The new testing method for silver corrosion has been performed on a significant portion of oils containing DBDS, as major reactive sulfur compound, which remained “non-corrosive” following the ASTM D1275-15 silver strip test. The method was demonstrated on five oils from free-breathing power transformers in service, containing DBDS in a wide range of concentrations (from approx. 40 to 200 mg/kg of DBDS). The new method comprises of a modification to the ASTM D 1275-15 test set up, by introducing longer test duration times and continuous oxygen ingress, which was found to be the most crucial parameter for promoting the formation of silver sulfide deposits. This was confirmed by EDX results, showing an increased sulfur weight percentage on silver strip after the test. The application of the modified ASTM silver corrosion test will contribute to improving the assessment of sulfur corrosion risk.

1 January 2022 in Zbornik Radova, Elektrotehnicki Institut Nikola Tesla
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
JJJelena Jankovic
Jelena Jankovic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
VIVladimir Ivančević
Vladimir Ivančević
JLJelena Lukic
Jelena Lukic
The Republic of Serbia signed and ratified the Stockholm Convention on Persistent Organic Pollutants. Law on ratification of the Stockholm Convention was adopted and actions were defined through the National Implementation Plan and the Action Plan. On their basis Project Proper Management and Final Disposal of Polychlorinated Biphenyls (PCBs) was created. Institute Nikola Tesla (INT) participated in the realization of the project. In the period from 2015 to 2022, 601 tons of PCB oil was successfully decontaminated by the INT mobile plant, i.e. the PCB content was below 50 mg/kg, which classified the power transformers (PT) as non-contaminated [1,2]. If PT becomes waste or in case of necessary repair or oil regeneration, the required limit value is 10 mg/kg. According to data from INT database there are still 2637 PTs containing PCBs in the concentration range of 2 to 50 mg/kg. In this paper application of the environmentally closed INT decontamination technology for achieving low values of PCB in the oil is shown.