Jelena Lukic

Dr. Jelena Lukic

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
DMDraginja Mihajlovic
Draginja Mihajlovic
BPBranko Pejovic
Branko Pejovic
MMMilovan Milovanovic
Milovan Milovanovic
Zoran RadakovićZoran Radaković
Zoran Radaković

4 May 2023 in Materials
Verified
Journal Article
Open access
PDF file
JJJelena Jankovic
Jelena Jankovic
JLJelena Lukic
Jelena Lukic
DKDejan Kolarski
Dejan Kolarski
DVDjordje Veljovic
Djordje Veljovic
Željko RadovanovićŽeljko Radovanović
Željko Radovanović
SDSilvana Dimitrijevic
Silvana Dimitrijevic
Elemental sulfur (S8) is a corrosive sulfur compound which was found to be extremely reactive to silver, causing intensive silver sulfide (Ag2S) deposition on on-load tap changer (OLTC) contacts in power transformers. A highly selective adsorbent (HSA), called Tesla’Ssorb, for the removal of S8 from mineral insulating oils was prepared from raw material (RM) using the novel procedure. In this study, the adsorption properties of HSA for the removal of S8 from the oil were determined. RM and HSA were characterized using various techniques, such as field-emission scanning electron microscopy (FESEM), energy-dispersive X-ray (EDX), and X-ray diffraction (XRD). The performance of HSA was determined by adsorption equilibrium, thermodynamic, and kinetic study through batch experiments, at various temperatures and initial concentrations of S8. The obtained results were analyzed by Langmuir and Freundlich adsorption isotherms and it was found that equilibrium data were fitted better with the Langmuir isotherm model. The maximum adsorption capacity was 4.84 mg of S8/g of HSA at 353 K. Thermodynamic parameters, such as enthalpy (ΔH°), Gibbs free energy (ΔG°), and entropy (ΔS°), were calculated and it was found that the sorption process was spontaneous (ΔG° < 0) and endothermic in nature (ΔH° > 0). It was found that the adsorption of S8 follows pseudo-second-order kinetic model, and the activation energy indicated the activated chemisorption process.

1 June 2023 in Polymers
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
The aim of this study is to propose a test method for the determination of the quality of transformer paper insulation. For this purpose, the oil/cellulose insulation systems were exposed to various accelerated aging tests. The results of the aging experiments of normal Kraft and thermally upgraded papers, two different types of transformer oil (mineral and natural ester), and copper are shown. Aging was carried out in various experiments at 150 °C, 160 °C, 170 °C, and 180 °C with dry (initial values ≤ 0.5%) and moistened cellulose insulation (initial values 3–3.5%). Following insulating oil and paper, degradation markers were measured: the degree of polymerization, tensile strength, furan derivates, methanol/ethanol, acidity, interfacial tension, and dissipation factor. It was found that the aging of cellulose insulation in cycles was 1.5–1.6 times faster in comparison to continuous aging, due to the more pronounced effect of hydrolytic mechanism in cyclic aging owing to the produced and absorbed water. Furthermore, it was observed that the high initial water content in cellulose increases the aging rate two to three times more than in the dry experimental setup. The proposed aging test in cycles can be used to achieve faster aging and to compare the quality of different insulating papers.

4 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
DMDraginja Mihajlovic
Draginja Mihajlovic
VIVladimir Ivancevic
Vladimir Ivancevic
VVValentina Engineering Institute Nikola Vasovic
Valentina Engineering Institute Nikola Vasovic
JLJelena Lukic
Jelena Lukic
This article presents a method for quantification of methanol and ethanol integrated in the same gas-chromatographic run with a quantification of gases dissolved in mineral oil, making it an integrated tool in transformer diagnostics. The results of aging experiments at 120 °C and 60 °C of Kraft paper, copper, barrier, and pressboard immersed in mineral oil, as well as the aging of thermal upgrade paper in mineral and natural ester oil at 140 °C are presented, in order to investigate correlations between different aging markers and to evaluate their partitioning between oil and cellulose at defined conditions. The results of partitioning experiments at 60 °C showed that re-absorption of methanol from oil to the cellulose materials is faster than the re-absorption of furans. This means that methanol is a paper-degradation marker that can be used in diagnostics over shorter equilibrium times and for the detection of developing faults at broader temperature ranges. Furthermore, a statistical overview of methanol concentration from a database and two transformer fault diagnostic cases are presented. Therefore, in addition to an analysis of gases dissolved in oil, the use of methanol and ethanol in transformer fault and failure investigations should be explored and verified through transformer fault investigations and postmortem analyses.

12 August 2025 in Materials
Verified
Journal Article
Open access
PDF file
DKDejan Kolarski
Dejan Kolarski
JLJelena Lukic
Jelena Lukic
JJJelena Jankovic
Jelena Jankovic
Sandra GlisicSandra Glisic
Sandra Glisic
Elemental sulfur (S8) reacts readily with silver, forming highly conductive silver sulfide on silver-coated components of on-load tap changers (OLTCs), forming a highly conductive silver sulfide film at the surface of an OLTC, which can lead to the failure of critical components in power transformers. This study investigates the reaction between metallic silver and elemental sulfur dissolved in mineral insulating oil across temperatures from 60 °C to 180 °C. The process involves three stages: the diffusion of sulfur through oil, surface reaction, and product diffusion. For low-viscosity oil, diffusion is not the limiting factor, and sulfur does not react immediately on the silver’s surface, suggesting possible adsorption or intermediate formation. A kinetic analysis revealed that the reaction follows first-order kinetics, with a change in mechanism above 150 °C. The reaction follows the Arrhenius equation in two separate regions: 60–150 °C and 150–180 °C. Activation energy was calculated as 23.67 kJ mol−1, and it can be concluded that the reaction is controlled by the diffusion of sulfur through mineral oil, and at higher temperatures (150 °C to 180 °C), the calculated activation energy is 160.69 kJ mol−1, which leads to the conclusion that the combined chemisorption and diffusion through a silver sulfide–oil interface becomes the new limiting factor.

28 March 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
JJJelena Jankovic
Jelena Jankovic
JLJelena Lukic
Jelena Lukic
DMDraginja Mihajlovic
Draginja Mihajlovic
MFMarc Foata
Marc Foata
BMBarry Myburgh
Barry Myburgh
Corrosive sulfur compounds in mineral insulating oils can easily react with metal surfaces in power transformers and form deposits, which can further cause failures of the electrical equipment. Copper sulfide formation has been well studied over the last couple of decades. However, silver sulfide formation also requires attention, due to significant number of failures of on-load tap changers caused by silver corrosion reported worldwide from different utilities. The conventional silver corrosion tests (DIN 51353 and ASTM D1275-15) do not provide adequate assessment of oil corrosivity against silver, even if the oil contains dibenzyl disulfide (DBDS) and other reactive sulfur compounds (disulfides and mercaptans) in high concentrations. The new testing method for silver corrosion has been performed on a significant portion of oils containing DBDS, as major reactive sulfur compound, which remained “non-corrosive” following the ASTM D1275-15 silver strip test. The method was demonstrated on five oils from free-breathing power transformers in service, containing DBDS in a wide range of concentrations (from approx. 40 to 200 mg/kg of DBDS). The new method comprises of a modification to the ASTM D 1275-15 test set up, by introducing longer test duration times and continuous oxygen ingress, which was found to be the most crucial parameter for promoting the formation of silver sulfide deposits. This was confirmed by EDX results, showing an increased sulfur weight percentage on silver strip after the test. The application of the modified ASTM silver corrosion test will contribute to improving the assessment of sulfur corrosion risk.