Amândio Manuel Cupido Santos

Prof. Dr. Amândio Manuel Cupido Santos

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2023 in Sports
Verified
Journal Article
Open access
PDF file
RNRafael Santos Neves
Rafael Santos Neves
MSMarco Antônio Rabelo Da Silva
Marco Antônio Rabelo Da Silva
MRMônica dos Anjos Costa de Rezende
Mônica dos Anjos Costa de Rezende
ACAdriana Caldo-Silva
Adriana Caldo-Silva
JPJoão Pinheiro
João Pinheiro
ASAmândio Manuel Cupido Santos
Amândio Manuel Cupido Santos
The use of saliva to monitor immune and hormonal responses in training, competitions, and during recovery is an easy and non-invasive alternative means of collecting samples compared to serum collection. Saliva can provide insight into a number of interesting biomarkers such as cortisol, testosterone, immunoglobulins, alpha-amylase, and melatonin, among others. High-intensity and exhaustive exercises, such as training or competition, provide variations in immune, protein and hormonal markers. An adequate recovery period, calming down, and recovery methods can contribute to a fast normalization of these markers, decreasing illness, as well as the likelihood of overtraining and injuries, but their effectiveness is still inconclusive. The aim of this review was to investigate the evidence of salivary markers in post-exhaustive exercise during the recovery period. This study is a systematic review from three electronic databases with studies from 2011 to 2021 within healthy humans. The search found 213 studies, and after applying the inclusion and exclusion criteria, while excluding duplicated studies, 14 studies were included in this review. The most cited salivary markers were cortisol and testosterone, as well as their ratio, alpha-amylase and IgA. Half of the studies applied a variety of recovery methods that showed controversial results over salivary markers’ impact. However, they showed an impact on the markers from the exercise, which was still dependent on exercise intensity, methodology, and duration.

26 April 2012 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
BGB. B. Gomes
B. B. Gomes
LMLuis Correia Mourão
Luis Correia Mourão
Alain MassartAlain Massart
Alain Massart
Pedro FigueiredoPedro Figueiredo
Pedro Figueiredo
João Paulo Vilas-BoasJoão Paulo Vilas-Boas
João Paulo Vilas-Boas
Ricardo FernandesRicardo Fernandes
Ricardo Fernandes
We purposed to study energy expenditure, power output and gross efficiency during kayak ergometer exercise in 12 elite sprint kayakers. 6 males (age 24.2±4.8 years, height 180.4±4.8 cm, body mass 79.7±8.5 kg) and 6 females (age 24.3±4.5 years, height 164.5±3.9 cm, body mass 65.4±3.5 kg), performed an incremental intermittent protocol on kayak ergometer with V˙O2 and blood lactate concentration assessment, a non-linear increase between power output and energy expenditure being observed. Paddling power output, energy expenditure and gross efficiency corresponding to V˙O2max averaged 199.92±50.41 W, 75.27±6.30 ml.kg − 1.min − 1, and 10.10±1.08%. Male kayakers presented higher V˙O2max, power output and gross efficiency at the V˙O2max, and lower heart rate and maximal lactate concentration than females, but no differences were found between genders regarding energy expenditure at V˙O2max. Aerobic and anaerobic components of energy expenditure evidenced a significant contribution of anaerobic energy sources in sprint kayak performance. Results also suggested the dependence of the gross efficiency on the changes in the amount of the aerobic and anaerobic contributions, at heavy and severe intensities. The inter-individual variance of the relationship between energy expenditure and the corresponding paddling power output revealed a relevant tracking for females (FDγ=0.73±0.06), conversely to the male group (FDγ=0.27±0.08), supporting that some male kayakers are more skilled in some paddling intensities than others.

1 May 2002 in Pediatric Exercise Science
Verified
Journal Article
Closed access
ASAmândio Manuel Cupido Santos
Amândio Manuel Cupido Santos
JWJoanne R. Welsman
Joanne R. Welsman
MCMark B.A. De Ste Croix
Mark B.A. De Ste Croix
NANeil Armstrong
Neil Armstrong
Age- and sex-related differences in optimal peak power (PPopt) and associated measures determined using a force-velocity (F-V) cycling test were examined in pre teenage, teenage and adult males and females. Absolute PPopt increased significantly with age in both males and females. With body mass controlled for using allometric scaling significant age related increases remained, an effect masked in the females when PPopt was expressed as W • kg−1. Sex differences in PPopt were minimal in the preteens but males demonstrated higher PPopt than females in both teenage and adult groups. These patterns of change with age and sex broadly reflect those obtained for Wingate Anaerobic Test determined PP but the use of a single non-optimized braking force underestimates the magnitude of any differences observed.

1 July 2019 in Transportation Research Part D: Transport and Environment
Verified
Journal Article
Closed access
DGDiego A. Giménez-Gaydou
Diego A. Giménez-Gaydou
ASAmândio Manuel Cupido Santos
Amândio Manuel Cupido Santos
GMGabriel Mendes
Gabriel Mendes
IFInês Frade
Inês Frade
ARAnabela Ribeiro
Anabela Ribeiro

1 April 2013 in Applied Physiology, Nutrition, and Metabolism
Verified
Journal Article
Closed access
JVJoao Valente-Dos-Santos
Joao Valente-Dos-Santos
Lauren SherarLauren Sherar
Lauren Sherar
MCManuel J Coelho-e-Silva
Manuel J Coelho-e-Silva
JPJoão Rafael Pereira
João Rafael Pereira
Vasco VazVasco Vaz
Vasco Vaz
RMRobert Malina
Robert Malina
Peak oxygen uptake (V̇O2peak) is routinely expressed in litres per minute and by unit of body mass (mL·kg−1·min−1) despite the theoretical and statistical limitations of using ratios. Allometric modeling is an effective approach for partitioning body-size effects in a performance variable. The current study examined the relationships among chronological age (CA), skeletal age (SA), total body and appendicular size descriptors, and V̇O2peakin male adolescent roller hockey players. Seventy-three Portuguese, highly trained male athletes (CA, 15.4 ± 0.6 years; SA, 16.4 ± 1.5 years; stature, 169.9 ± 6.9 cm; body mass, 63.7 ± 10.7 kg; thigh volume, 4.8 ± 1.0 L) performed an incremental maximal test on a motorized treadmill. Exponents for body size descriptors were 2.15 for stature (R2= 0.30, p < 0.01) and 0.55 for thigh volume (R2= 0.46, p < 0.01). The combination of stature or thigh volume and CA or SA, and CA2or SA2, increased the explained variance in V̇O2peak(R2ranged from 0.30 to 0.55). The findings of the allometric model combining more than 1 body size descriptor (i.e., stature and thigh volume) in addition to SA and CA2were not significant. Results suggest that thigh volume and SA are the main contributors to interindividual variability in aerobic fitness.

22 June 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Raynier Montoro-BombúRaynier Montoro-Bombú
Raynier Montoro-Bombú
BGBeatriz Gomes
Beatriz Gomes
ASAmândio Manuel Cupido Santos
Amândio Manuel Cupido Santos
LRLuis Rama
Luis Rama
In recent years, there has been an exponential increase in the number of devices developed to measure or estimate physical exercise. However, before these devices can be used in a practical and research environment, it is necessary to determine their validity and reliability. The purpose of this study is to test the validity and reliability of a load cell sensor-based device (LC) for measuring the peak force (PFr) and the rate of force development (RFD) during the isometric mid-thigh pull (IMTP) test, using a force plate (FP) as the gold standard. Forty-two undergraduate sport science students (male and female) participated in this study. In a single session, they performed three repetitions of the IMTP test, being tested simultaneously with an LC device and a Kistler force platform (FP). The PFr and RFD data were obtained from the force-time curve of the FP and compared with the LC data, provided automatically by the software of the device (Smart Traction device©). The mean difference between the results obtained by the LC device and the gold-standard equipment (FP) was not significantly different (p > 0.05), for both PFr and RFD, which suggests the validity of the ST results. Bland–Altman analysis showed a small mean difference in PFr = 1.69 N, upper bound = 47.88 N, and lower bound = −51.27 N. RFD showed that the mean difference was −5.27 N/s, upper limit = 44.36 N/s, and lower limit = −54.91 N/s. Our results suggest that the LC device can be used in the assessment of the isometric-mid-thigh-pull test as a valid and reliable tool. It is recommended that this device’s users consider these research results before putting the ST into clinical practice.