Rémy Gauthier

Mr. Rémy Gauthier

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2022 in Materials
Verified
Journal Article
Open access
PDF file
BGBrigitte GROSGOGEAT
Brigitte GROSGOGEAT
ASAlina Sakalauskiene
Alina Sakalauskiene
Rémy GauthierRémy Gauthier
Rémy Gauthier
CJChristine Janssen
Christine Janssen
Marc Le BorgneMarc Le Borgne
Marc Le Borgne
Background: The toxicological risk of Co-Cr dental alloys is actually a sensitive subject with the European regulatory changes, namely regulation (EU) 2017/745 and annex VI to the CLP regulation (EC) 1972/2008. Objectives: The objective of this review is to conduct a rigorous analysis of the cytocompatibility of cobalt–chromium (Co-Cr) dental alloys. Considering various parameters such as cytotoxicity, type IV hypersensitivity reaction, sensitization, and irritation, we investigated evidence of toxicity of Co-Cr in human dental applications. Data sources: Specific search strategies were performed in three electronic databases, namely Medline, Embase, and Web of Science, using a main restriction in the search regarding the publication date (1995–2022). Study selection: Out of a total of 836 articles, only 21 studies were selected and analyzed according to PRISMA methodology. Results: Among them, 10 in vitro studies using human samples and 11 in vivo studies on human patients were distinguished. Most of the in vitro studies confirmed that Co-Cr alloys have a good cytocompatibility compared to Ni alloys. Regarding the in vivo studies, it appeared that Co-Cr could rarely cause sensitization, irritation, and allergic reactions. Reactions were mainly observed for people allergic to Co or Cr. Nevertheless, titanium-based materials showed better results. Conclusions: This study proposes a new state of the art on Co-Cr dental alloys and will thus be very useful for carrying out additional studies. Relevance: This review will help practitioners in their daily clinical choice.

17 June 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
GKGeorgia-Ioanna Kontogianni
Georgia-Ioanna Kontogianni
Catarina CoelhoCatarina Coelho
Catarina Coelho
Rémy GauthierRémy Gauthier
Rémy Gauthier
Sonia FiorilliSonia Fiorilli
Sonia Fiorilli
PQPaulo Quadros
Paulo Quadros
Maria ChatzinikolaidouMaria Chatzinikolaidou
Maria Chatzinikolaidou
Nanohydroxyapatite (nanoHA) is the major mineral component of bone. It is highly biocompatible, osteoconductive, and forms strong bonds with native bone, making it an excellent material for bone regeneration. However, enhanced mechanical properties and biological activity for nanoHA can be achieved through enrichment with strontium ions. Here, nanoHA and nanoHA with a substitution degree of 50 and 100% of calcium with strontium ions (Sr-nanoHA_50 and Sr-nanoHA_100, respectively) were produced via wet chemical precipitation using calcium, strontium, and phosphorous salts as starting materials. The materials were evaluated for their cytotoxicity and osteogenic potential in direct contact with MC3T3-E1 pre-osteoblastic cells. All three nanoHA-based materials were cytocompatible, featured needle-shaped nanocrystals, and had enhanced osteogenic activity in vitro. The Sr-nanoHA_100 indicated a significant increase in the alkaline phosphatase activity at day 14 compared to the control. All three compositions revealed significantly higher calcium and collagen production up to 21 days in culture compared to the control. Gene expression analysis exhibited, for all three nanoHA compositions, a significant upregulation of osteonectin and osteocalcin on day 14 and of osteopontin on day 7 compared to the control. The highest osteocalcin levels were found for both Sr-substituted compounds on day 14. These results demonstrate the great osteoinductive potential of the produced compounds, which can be exploited to treat bone disease.

1 March 2019 in Journal of Biomechanics
Verified
Journal Article
Closed access
Rémy GauthierRémy Gauthier
Rémy Gauthier
MLMax Langer
Max Langer
HFHelene FOLLET
Helene FOLLET
COCécile Olivier
Cécile Olivier
PGPierre-Jean Gouttenoire
Pierre-Jean Gouttenoire
FPFrançoise Peyrin
Françoise Peyrin

24 July 2024 in Journal of Structural Biology
Verified
Journal Article
Open access
BYBoliang Yu
Boliang Yu
Rémy GauthierRémy Gauthier
Rémy Gauthier
COCécile Olivier
Cécile Olivier
JVJulie Villanova
Julie Villanova
HFHélène Follet
Hélène Follet
FPFrancoise Peyrin
Francoise Peyrin
Osteocytes are the major actors in bone mechanobiology. Within bone matrix, they are trapped close together in a submicrometric interconnected network: the lacunocanalicular network (LCN). The interstitial fluid circulating within the LCN transmits the mechanical information to the osteocytes that convert it into a biochemical signal. Understanding the interstitial fluid dynamics is necessary to better understand the bone mechanobiology. Due to the submicrometric dimensions of the LCN, making it difficult to experimentally investigate fluid dynamics, numerical models appear as a relevant tool for such investigation. To develop such models, there is a need for geometrical and morphological data on the human LCN. This study aims at providing morphological data on the human LCN from measurement of 27 human femoral diaphysis bone samples using synchrotron radiation nano-computed tomography with an isotropic voxel size of 100 nm. Except from the canalicular diameter, the canalicular morphological parameters presented a high variability within one sample. Some differences in terms of both lacunar and canalicular morphology were observed between the male and female populations. But it has to be highlighted that all the canaliculi cannot be detected with a voxel size of 100 nm. Hence, in the current study, only a specific population of large canaliculi that could be characterize. Still, to the authors knowledge, this is the first time such a data set was introduced to the community. Further processing will be achieved in order to provide new insight on the LCN permeability.

7 March 2023 in Biomimetics
Verified
Journal Article
Open access
PDF file
Rémy GauthierRémy Gauthier
Rémy Gauthier
Nina AttikNina Attik
Nina Attik
CCCharlène Chevalier
Charlène Chevalier
VSVincent Salles
Vincent Salles
BGBrigitte GROSGOGEAT
Brigitte GROSGOGEAT
ATA.-M. Trunfio-Sfarghiu
A.-M. Trunfio-Sfarghiu
While periodontal ligament cells are sensitive to their 3D biomechanical environment, only a few 3D in vitro models have been used to investigate the periodontal cells mechanobiological behavior. The objective of the current study was to assess the capability of a 3D fibrous scaffold to transmit a mechanical loading to the periodontal ligament cells. Three-dimensional fibrous polycaprolactone (PCL) scaffolds were synthetized through electrospinning. Scaffolds seeded with human periodontal cells (103 mL−1) were subjected to static (n = 9) or to a sinusoidal axial compressive loading in an in-house bioreactor (n = 9). At the end of the culture, the dynamic loading seemed to have an influence on the cells’ morphology, with a lower number of visible cells on the scaffolds surface and a lower expression of actin filament. Furthermore, the dynamic loading presented a tendency to decrease the Alkaline Phosphatase activity and the production of Interleukin-6 while these two biomolecular markers were increased after 21 days of static culture. Together, these results showed that load transmission is occurring in the 3D electrospun PCL fibrous scaffolds, suggesting that it can be used to better understand the periodontal ligament cells mechanobiology. The current study shows a relevant way to investigate periodontal mechanobiology using 3D fibrous scaffolds.

1 November 2018 in Dental Materials
Verified
Journal Article
Closed access
NCNancie Cougot
Nancie Cougot
TDThierry Douillard
Thierry Douillard
FDFlorent Dalmas
Florent Dalmas
NPNelly Pradelle
Nelly Pradelle
Rémy GauthierRémy Gauthier
Rémy Gauthier
JCJérome Chevalier
Jérome Chevalier