Background and Objectives: This study aimed to evaluate the surface roughness evolution of several finished and polished composites when bleaching materials are applied. The research was conducted on four microhybrid or nanofilled composites that are used in dental restorations. Materials and Methods: For each composite type, 5 samples were selected for control, 5 samples were subjected to the bleaching protocol “office bleach” with 40% hydrogen peroxide, and 5 other samples were subjected to the “home bleach” protocol with 16% carbamide peroxide, resulting in a total number of 60 samples. The surfaces of all the samples were tested for roughness, and the values of the most relevant parameter (Ra), were collected. Comparisons between composites and samples were performed using one-way ANOVA (in Statistical Package for Social Sciences). Results: After the bleaching protocol with 40% hydrogen peroxide gel, it was found that the roughness of the group increased considerably compared to the control group, so the highest roughness was found at GC Gradia direct anterior group, and the lowest value was registered for the 3M ESPE Valux Plus group. Following the bleaching protocol with 16% carbamide peroxide (home bleach), it was noted that the sample surfaces were not as affected. In this case, the lowest roughness was found at 3M ESPE Valux Plus group, and the highest roughness was registered for the GC G-aenial anterior group. Following the interpretation of the results, all four types of dental composites tested showed significant surface roughness differences between the groups subjected to bleaching protocols and those kept as control (p < 0.05). Conclusions: The surfaces of the samples were affected by the bleaching protocols by increasing the roughness compared to the control samples.
20 December 2024 in Romanian Journal of Oral Rehabilitation
Polymethyl methacrylate (PMMA) is a versatile polymer widely used in medical, dental, and cosmetic applications due to its impressive transparency, biocompatibility, and stability against environmental factors. This review examines recent advancements in PMMA composites aimed at enhancing biocompatibility and reducing toxicity, particularly in medical applications. Innovations include the integration of nanoparticles to improve mechanical properties and reduce bacterial colonization, as well as the development of novel composites that exhibit increased durability and enhanced cellular interactions. Additionally, the review discusses the implications of these advancements for medical and dental practices, emphasizing the importance of material selection in clinical outcomes. It also highlights the ongoing challenges and potential health risks associated with PMMA, particularly concerning its interaction with biological systems. The integration of cutting-edge research and technology in PMMA composites is crucial for developing safer, more effective medical devices and interventions, ultimately leading to better patient outcomes and broader applications in healthcare.
The success of endodontic treatment is dependent on the removal of bacteria. A modern strategy to reduce bacterial load is laser irradiation. During this procedure, there is a local increase in temperature with possible side effects. The aim of this study was to determine the thermal behavior of a maxillary first molar when performing the conventional irradiation technique using a diode laser. For this study, a 3D virtual model of a maxillary first molar was created. The preparation of the access cavity, the rotary instrumentation of the palatal root canal and the laser irradiation protocol were simulated. The model was exported in a finite element analysis program where the temperature and heat flux were studied. Temperature and heat flux maps were obtained, and the temperature increase on the internal wall of the root canal was analyzed. The maximum temperature value exceeded 400 °C and was maintained for less than 0.5 s. The obtained temperature maps support the bactericidal effect of diode laser and the limitation of damage to surrounding tissues. On internal root walls, the temperature reached several hundred degrees Celsius, but for very short durations. Conventional laser irradiation is an adjuvant method of decontamination of the endodontic system.
The restoration of class II cavities is predominantly carried out with composite materials. Due to the high failure rate in restoring this type of cavity, composite materials with much-improved properties and new application techniques have been promoted. The study aimed to analyze the mechanical behavior of several topical composite materials (nanocomposites, nanohybrids and ormocer) using different application techniques. In a lower second molar, a class II occlusal cavity was prepared. As filling materials, we used the following combinations: Admira Fusion and Admira Fusion Flow, Grandio and Grandio Flow, Filtek Supreme XT and Filtek Supreme Flow. These were applied using a snow plow, injection molded and Bichacho techniques. Three-dimensional scanning of the molar with the prepared cavity was performed, and then scanning of each layer of added composite material was performed, obtaining three-dimensional models. The virtual molar models were analyzed with software specific to the finite element analysis method, where their physical-mechanical properties were entered and assigned to the components of the virtual molar. Simulations at high forces specific to bruxism were then carried out and analyzed, and compared. The values of displacements and strain, for all six analyzed situations, are relatively small (range from 5.25 × 10−6–3.21 × 10−5 for displacement, 6.22 × 10−3–4.34 × 10−3 for strain), which validates all three methods and the materials used. As far as the stress values are concerned, they are similar for all methods (250–300 MPa), except for the snow plow and injection-molded techniques using Grandio and Grandio Flow composites, where the maximum von Mises stress value was more than double (approximately 700 MPa). When using the combination of Grandio and Grandio Flow materials, the 1 mm thickness of the fluid composite layer was found to have a major influence on occlusal forces damping as opposed to 0.5 mm. Therefore, the Bichacho technique is indicated at the expense of the snow plow and injection-molded techniques. The composite materials used by us in this study are state-of-the-art, with clear indications for restoring cavities resulting from the treatment of carious lesions. However, their association and application technique in the case of Class II cavities is of clinical importance for resistance to masticatory forces.
The possibility of dental pulp damage during dental procedures is well known. According to studies, during finishing and polishing without cooling, temperatures of up to 140 °C or more can be generated. There are many studies that have analysed the influence of the finishing and polishing of fillings on the mechanical parameters, but the analysis of thermal parameters has led to uncertain results due to the difficulty of performing this in vivo. Background: We set out to conduct a study, using the finite element method, to determine the extent to which the type of class II cavity and the volume of the composite filling influence the duration of heat transfer to the pulp during finishing and polishing without cooling. Materials and Methods: A virtual model of an upper primary molar was used, with a caries process located on the distal aspect, in which four types of cavities were digitally prepared: direct access, horizontal slot, vertical slot and occlusal–proximal. All four cavity types were filled using a Filtek Supreme XT nanocomposite. Results: The study showed that the filling volume almost inversely proportionally influences the time at which the dental pulp reaches the critical temperature of irreversible damage. The lowest duration occurred in occlusal–distal restorations and the highest in direct access restorations. Conclusions: based on the results of the study, a working protocol can be issued so that finishing and polishing restorations without cooling are safe for pulpal health.
CBCT (cone beam computed tomography) is an imaging investigation that provides three-dimensional (3D) images of craniofacial structures. The purpose of this study is to determine the mechanical behavior of an orthodontic system where the lingual treatment technique was used in a 25-year-old female patient from whom a set of CBCT scans was used. CBCT images were processed through software programs such as Invesalius, Geomagic, and Solid Works, to create models containing virtual solids. These models were then imported into Ansys Workbench 2019 R3 (a finite element method software program) for successive simulations to generate displacement maps, deformations, stress distributions, and diagrams. We observed that in the lingual technique, the lowest force occurring on the maxillary teeth is at 1.1, while the highest force appears at 2.3. In the mandible, the lowest force occurs at 4.6, and the highest force at 3.1. The values of the forces and the results of the finite element method can represent a basis for the innovation of new orthodontic springs and also of bracket elements. Thus, by using new technologies, orthodontic practice can be significantly improved for the benefit of patients. Other virtual methods and techniques can be used in future studies, including the application of virtual reality for orthodontic diagnosis.
About Me
Cristian Niky Cumpătă is a assiociate professor of Oromaxillofacial Surgery.
Cristian Niky Cumpătă is a assiociate professor of Oromaxillofacial Surgery.