Oana Andreea Diaconu

Dr. Oana Andreea Diaconu


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
MȚMihaela Jana Țuculină
Mihaela Jana Țuculină
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
ADAlina Duta
Alina Duta
ASAlex Ioan Sălan
Alex Ioan Sălan
IDIonela Teodora Dascălu
Ionela Teodora Dascălu
Cone beam computed tomography (CBCT) is a modern imaging technique that uses X-rays to investigate the structures of the dento-maxillary apparatus and obtain detailed images of those structures. The aim of this study was to determine a functional mathematical model able to evaluate the elastic force intensity on each bracket and tube type element and the ways in which those components act on the orthodontic system being used. To analyze a real orthodontic system, we studied the case of a 13-year-old female patient. To transfer geometric information from tomographic images, we used the InVesalius software. This software can generate three-dimensional reconstructions based on sequences and files in the DICOM format and was purchased from CBCT equipment. We analyzed and processed the geometries of the converted tissues in InVesalius using the Geomagic software. After using the Geomagic software, we exported the resulting model to the SolidWorks software used in computer-aided design. In this software, the model is transformed into a virtual solid. After making the geometric model, we analyzed the model using the Ansys Workbench software, which incorporates finite element analysis techniques. Following the simulations, we obtained result maps, which showed the complete mechanical behavior of the analyzed structures.

1 June 2023 in Medicina
Verified
Journal Article
Open access
PDF file
APAlexandru-Dan Popescu
Alexandru-Dan Popescu
MȚMihaela Jana Țuculină
Mihaela Jana Țuculină
ODOana Andreea Diaconu
Oana Andreea Diaconu
LGLelia Mihaela Gheorghita
Lelia Mihaela Gheorghita
Claudiu NicolicescuClaudiu Nicolicescu
Claudiu Nicolicescu
RVRuxandra Voinea-Georgescu
Ruxandra Voinea-Georgescu
Background and Objectives: This study aimed to evaluate the surface roughness evolution of several finished and polished composites when bleaching materials are applied. The research was conducted on four microhybrid or nanofilled composites that are used in dental restorations. Materials and Methods: For each composite type, 5 samples were selected for control, 5 samples were subjected to the bleaching protocol “office bleach” with 40% hydrogen peroxide, and 5 other samples were subjected to the “home bleach” protocol with 16% carbamide peroxide, resulting in a total number of 60 samples. The surfaces of all the samples were tested for roughness, and the values of the most relevant parameter (Ra), were collected. Comparisons between composites and samples were performed using one-way ANOVA (in Statistical Package for Social Sciences). Results: After the bleaching protocol with 40% hydrogen peroxide gel, it was found that the roughness of the group increased considerably compared to the control group, so the highest roughness was found at GC Gradia direct anterior group, and the lowest value was registered for the 3M ESPE Valux Plus group. Following the bleaching protocol with 16% carbamide peroxide (home bleach), it was noted that the sample surfaces were not as affected. In this case, the lowest roughness was found at 3M ESPE Valux Plus group, and the highest roughness was registered for the GC G-aenial anterior group. Following the interpretation of the results, all four types of dental composites tested showed significant surface roughness differences between the groups subjected to bleaching protocols and those kept as control (p < 0.05). Conclusions: The surfaces of the samples were affected by the bleaching protocols by increasing the roughness compared to the control samples.

27 April 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
MKMahmoud KATTA Katta
Mahmoud KATTA Katta
Stelian-Mihai-Sever PetrescuStelian-Mihai-Sever Petrescu
Stelian-Mihai-Sever Petrescu
LDLucian Paul Dragomir
Lucian Paul Dragomir
MPMihai Raul Popescu
Mihai Raul Popescu
RGRuxandra Voinea Georgescu
Ruxandra Voinea Georgescu
IDIonela Teodora Dascălu
Ionela Teodora Dascălu
The finite element method (FEM) is a computational method that can solve all biomechanical problems, including the field of orthodontics. The purpose of this virtual experimental study is to determine the behavior of a real orthodontic system subjected to different systems of loads. To analyze the real orthodontic system, we studied the case of a 21-year-old female patient. We used the InVesalius program, which can transform a set of DICOM-type images taken from cone beam computed tomography (CBCT) into three-dimensional structures. These structures were edited, modified, completed, and analyzed from a geometric point of view with the help of the Geomagic software. The final result of these operations must be a three-dimensional model made up of perfectly closed surfaces so that they can be transformed into virtual solids. The model consisting of perfectly closed surfaces is loaded into computer-aided design (CAD) programs. Bracket and tube components, as well as orthodontic wires, can be added to these models, similar to the analyzed patient’s tissues. When the model is complete and geometrically correct, it is exported to a program that uses FEM, such as Ansys Workbench. The simulation was performed for the forces of 0.5, 0.6, 0.7, 0.8, 0.9, and 1 N. The intention was to determine the behavior of the entire orthodontic system for these force values. After running the simulations, result maps were obtained that were composed of displacement, strain, and stress diagrams. It was also found that, in addition to the known rigidity, the orthodontic system has some elasticity due to the orthodontic wires, as well as the periodontal ligaments. Thus, a virtual analysis study can be carried out starting from a real patient with pre-treatment CBCT images and the virtual models of the bracket and tube elements and of the orthodontic wires.

16 May 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
ASAdrian Ștefan Stănuși
Adrian Ștefan Stănuși
DPDragos-Laurentiu Popa
Dragos-Laurentiu Popa
MIMihaela Ionescu
Mihaela Ionescu
CCCristian Niky Cumpătă
Cristian Niky Cumpătă
GPGabriel Sebastian Petrescu
Gabriel Sebastian Petrescu
ASAndreea Stanusi
Andreea Stanusi
The success of endodontic treatment is dependent on the removal of bacteria. A modern strategy to reduce bacterial load is laser irradiation. During this procedure, there is a local increase in temperature with possible side effects. The aim of this study was to determine the thermal behavior of a maxillary first molar when performing the conventional irradiation technique using a diode laser. For this study, a 3D virtual model of a maxillary first molar was created. The preparation of the access cavity, the rotary instrumentation of the palatal root canal and the laser irradiation protocol were simulated. The model was exported in a finite element analysis program where the temperature and heat flux were studied. Temperature and heat flux maps were obtained, and the temperature increase on the internal wall of the root canal was analyzed. The maximum temperature value exceeded 400 °C and was maintained for less than 0.5 s. The obtained temperature maps support the bactericidal effect of diode laser and the limitation of damage to surrounding tissues. On internal root walls, the temperature reached several hundred degrees Celsius, but for very short durations. Conventional laser irradiation is an adjuvant method of decontamination of the endodontic system.

Verified
Journal Article
Open access
PDF file
CDCezar Diaconu
Cezar Diaconu
ADAnca Elena Diaconu
Anca Elena Diaconu
MȚMihaela Jana Țuculină
Mihaela Jana Țuculină
LMLaurenta Lelia Mihai
Laurenta Lelia Mihai
MGMircea Gheorghiță
Mircea Gheorghiță
ODOana Andreea Diaconu
Oana Andreea Diaconu
This in vitro study aims to assess the cyclic fatigue resistance of the Protaper Ultimate (PTU) files compared to the Protaper Gold (PTG) and the M3 UDG (M3) files using various motion kinematics in simulated canals. As far as the authors are aware, no study has previously compared the three file systems before this current investigation. Therefore, closing this information gap is the goal of the current research. Methods: A total of (60 new endodontic files were randomly divided into 6 groups (10 files per group); groups 1, 3, and 5 used continuous rotation (CR), while groups 2, 4, and 6 used forward reciprocating motion (FRM). A manufactured stainless-steel artificial canal was used to perform the cyclic fatigue testing. The results were analyzed using Student’s t-test and two-way ANOVA. All pairwise comparisons revealed statistically significant differences in the time to failure (TTF) for every study group (p < 0.001), with the exception of the PTG and M3 files, which performed similarly using both CR and FRM. Conclusions: The PTU files performed better than the PTG and M3 files in terms of the TTF and number of cycles to failure (NCF) using both CR and FRM.

Verified
Journal Article
Open access
PDF file
SAStaicu Adela-Nicoleta
Staicu Adela-Nicoleta
MȚMihaela Jana Țuculină
Mihaela Jana Țuculină
CCCristian Niky Cumpătă
Cristian Niky Cumpătă
ARAna Maria Rîcă
Ana Maria Rîcă
MBMaria Cristina Bezna
Maria Cristina Bezna
ODOana Andreea Diaconu
Oana Andreea Diaconu
The possibility of dental pulp damage during dental procedures is well known. According to studies, during finishing and polishing without cooling, temperatures of up to 140 °C or more can be generated. There are many studies that have analysed the influence of the finishing and polishing of fillings on the mechanical parameters, but the analysis of thermal parameters has led to uncertain results due to the difficulty of performing this in vivo. Background: We set out to conduct a study, using the finite element method, to determine the extent to which the type of class II cavity and the volume of the composite filling influence the duration of heat transfer to the pulp during finishing and polishing without cooling. Materials and Methods: A virtual model of an upper primary molar was used, with a caries process located on the distal aspect, in which four types of cavities were digitally prepared: direct access, horizontal slot, vertical slot and occlusal–proximal. All four cavity types were filled using a Filtek Supreme XT nanocomposite. Results: The study showed that the filling volume almost inversely proportionally influences the time at which the dental pulp reaches the critical temperature of irreversible damage. The lowest duration occurred in occlusal–distal restorations and the highest in direct access restorations. Conclusions: based on the results of the study, a working protocol can be issued so that finishing and polishing restorations without cooling are safe for pulpal health.