Manuel Kuder

Dr. Manuel Kuder

Department of Electrical Engineering, Bundeswehr University Munich, Werner-Heisenberg-Weg 39, 85579 Neubiberg, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
OTOskar Theliander
Oskar Theliander
AKAnton Kersten
Anton Kersten
MKManuel Kuder
Manuel Kuder
Weiji HanWeiji Han
Weiji Han
EGEmma Arfa Grunditz
Emma Arfa Grunditz
TTTorbjörn Thiringer
Torbjörn Thiringer
This paper deals with the modeling and the parameterization of high-power, LiFePO4 battery packs used in cascaded H-bridge multilevel propulsion inverters. Since the battery packs are intermittently conducting the motor currents, the battery cells are stressed with a dynamic current containing a substantial amount of low-order harmonic components up to a couple of kHz, which is a major difference in comparison to a traditional two-level inverter drive. Different models, such as pure resistive and dynamic RC-networks, are considered to model the energy losses for different operating points and driving cycles. Using a small-scale setup, the models' parameters are extracted using both a low-frequency, pulsed current and an electrochemical impedance spectroscopy sweep. The models are compared against measurements conducted on the small-scale setup at different operating points. Additionally, a drive cycle loss comparison is simulated. The simple resistive model overestimates the losses by about 20% and is, thus, not suitable. The dynamic three-time constant model, parameterized by a pulsed current, complies with the measurements for all analyzed operating points, especially at low speed, with a maximum deviation of 3.8%. Extracting the parameters using an electrochemical impedance spectroscopy seems suitable for higher speeds, though the losses for the chosen operating points are underestimated by 1.5% to 7.9%.

23 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
JEJulian Estaller
Julian Estaller
AKAnton Kersten
Anton Kersten
MKManuel Kuder
Manuel Kuder
TTTorbjörn Thiringer
Torbjörn Thiringer
RERichard Eckerle
Richard Eckerle
TWThomas Weyh
Thomas Weyh
Electrical models of battery cells are used in simulations to represent batteries’ behavior in various fields of research and development involving battery cells and systems. Electrical equivalent circuit models, either linear or nonlinear, are commonly used for this purpose and are presented in this article. Various commercially available cylindrical, state-of-the-art lithium-ion battery cells, both protected and unprotected, are considered. Their impedance properties, according to four different equivalent circuit models, are measured using electrochemical impedance spectroscopies. Furthermore, the pricing, impedance, specific energy, and C-rate of the chosen battery cells are compared. For example, it is shown that the energy density of modern 18650 cells can vary from a typical value of 200 to about 260 Wh kg−1, whereas the cell price can deviate by a factor of about 3 to 5. Therefore, as a result, this study presents a concise but comprehensive battery parameter library that should aid battery system designers or power electronic engineers in conducting battery simulations and in selecting appropriate battery cells based on application-specific requirements. In addition, the accuracies and computational efforts of the four equivalent circuit models are compared.

17 April 2023 in Energies
Verified
Journal Article
Open access
PDF file
FAFurqan A. Abbas
Furqan A. Abbas
Thealfaqar A. Abdul-jabbarThealfaqar A. Abdul-jabbar
Thealfaqar A. Abdul-jabbar
AOAdel A. Obed
Adel A. Obed
AKAnton Kersten
Anton Kersten
MKManuel Kuder
Manuel Kuder
TWThomas Weyh
Thomas Weyh
The use of renewable energy sources such as solar photovoltaic, wind, and fuel cells is becoming increasingly prevalent due to a combination of environmental concerns and technological advancements, as well as decreasing production costs. Power electronics DC-DC converters play a key role in various applications, including hybrid energy systems, hybrid vehicles, aerospace, satellite systems, and portable electronic devices. These converters are used to convert power from renewable sources to meet the demands of the load, improving the dynamic and steady-state performance of green generation systems. This study presents a comparison of the most commonly used non-isolated DC-DC converters for fuel cell applications. The important factors considered in the comparison include voltage gain ratio, voltage switch stress, voltage ripple, efficiency, cost, and ease of implementation. Based on the comparison results, the converters have been grouped according to voltage level applications, with low voltage applications being best served by converters such as DBC, DuBC, TLBC, 2-IBC, 1st M-IBC, PSOL, SEPIC, and 1st M-SEPIC owing to their lower cost, smaller size, and reduced switch stress. Medium voltage applications are best suited to converters such as TBC, 1st M-TLBC, 2nd M-TLBC, 4-IBC, 1st M-IBC, 2nd M-IBC, 1st M-PSOL, 2nd M-PSOL, 1st M-SEPIC, and 2nd M-SEPIC, which offer higher efficiency. Finally, high voltage applications are best served by converters such as TBC, 1st M-TBC, 2nd M-IBC, 3rd M-IBC, 3rd M-PSOL, 4th M-PSOL, 2nd M-SEPIC, 3rd M-SEPIC, and 4th M-SEPIC.

4 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
AKAnton Kersten
Anton Kersten
ARArtem Rodionov
Artem Rodionov
MKManuel Kuder
Manuel Kuder
THThomas Hammarström
Thomas Hammarström
ALAnton Lesnicar
Anton Lesnicar
TTTorbjörn Thiringer
Torbjörn Thiringer
Battery electric vehicles demand a wide variety of charging networks, such as charging stations and wallboxes, to be set up in the future. The high charging power (typically in the range of a couple of kW up to a couple of hundred kW) and the possibly long duration of the charging process (up to more than 24 h) put some special requirements on the electrical infrastructure of charging stations, sockets, and plugs. This paper gives an overview of the technical design requirements and considerations for vehicle charging stations, sockets, and plugs, including their infrastructure, according to the Swedish Standard 4364000, “Low-voltage electrical installations—Rules for design and erection of electrical installations”, and the corresponding harmonized European standards. In detail, the four internationally categorized charging modes are explained and the preferable charging plugs, including their two-bus communication, according to European Directives are shown. The dimensioning of the supply lines and the proper selection of the overcurrent protection device, the insulation monitor, and the residual current device are described. Furthermore, a comprehensive overview of the required safety measures, such as the application of an isolation transformer or the implementation of an overvoltage protection mechanism, and the limits for conducted electromagnetic emissions, such as low-frequency harmonics or high-frequency (150 kHz to 108 MHz) emissions, are given.

5 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
AKAnton Kersten
Anton Kersten
MKManuel Kuder
Manuel Kuder
TTTorbjörn Thiringer
Torbjörn Thiringer
This paper shows a preliminary study about the output voltage modulation of a modular battery system based on a seven-level cascaded H-bridge inverter used for vehicle propulsion. Two generally known modulation techniques, pulse width modulation (PWM) and fundamental selective harmonic elimination (FSHE), are extensively compared for such an innovative modular battery system inverter considering EVs’ broad torque-speed range. The inverter and the battery losses, as well as the inverter-induced current THD, are modeled and quantified using simulations. At low speeds, if the modulation index M is below 0.3, FSHE induces a high current THD (>>5%) and, thus, cannot be used. At medium speeds, FSHE reduces the drivetrain losses (including the battery losses), while operating at higher speeds, it even reduces the current THD. Thus, an individual boundary between multilevel PWM and FSHE can be determined using weightings for efficiency and current quality. Based on this, a simple hybrid modulation technique is suggested for modular battery system inverters, improving the simulated drive cycle efficiency by a maximum of 0.29% to 0.42% for a modeled small passenger vehicle. Furthermore, FSHE’s high speed dominance is demonstrated using a simple experimental setup with an inductive load.

13 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
MKManuel Kuder
Manuel Kuder
AKAnton Kersten
Anton Kersten
JMJose-Luis Marques-Lopez
Jose-Luis Marques-Lopez
JEJulian Estaller
Julian Estaller
JBJohannes Buberger
Johannes Buberger
RERichard Eckerle
Richard Eckerle
This paper presents a novel capacitor voltage balancing control approach for cascaded multilevel inverters with an arbitrary number of series-connected H-Bridge modules (floating capacitor modules) with asymmetric voltages, tiered by a factor of two (binary asymmetric). Using a nearest-level reference waveform, the balancing approach uses a one-step-ahead approach to find the optimal switching-state combination among all redundant switching-state combinations to balance the capacitor voltages as quickly as possible. Moreover, using a Lyapunov function candidate and considering LaSalle’s invariance principle, it is shown that an offline calculated trajectory of optimal switching-state combinations for each discrete output voltage level can be used to operate (asymptotically stable) the inverter without measuring any of the capacitor voltages, achieving a novel sensorless control as well. To verify the stability of the one-step-ahead balancing approach and its sensorless variant, a demonstrator inverter with 33 levels is operated in grid-tied mode. For the chosen 33-level converter, the NPC main-stage and the individual H-bridge modules are operated with an individual switching frequency of about 1 kHz and 2 kHz, respectively. The sensorless approach slightly reduced the dynamic system response and, furthermore, the current THD for the chosen operating point was increased from 3.28 to 4.58 in comparison with that of using the capacitor voltage feedback.