Thomas Hammarström

Prof. Thomas Hammarström


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2022 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
EBEbrahim Balouji
Ebrahim Balouji
THThomas Hammarström
Thomas Hammarström
TMTomas McKelvey
Tomas McKelvey
A partial discharge (PD) is a small, localized breakdown which often appears in high-voltage insulation systems. PDs can be initiated within material defects such as voids or cracks when exposed to sufficiently high electric field levels. In this research work, we study and propose a machine learning (ML) approach to detect and classify PDs originating from multilevel pulsewidth modulation (PWM) waveforms as utilized in power electronic devices, such as inverters and variable frequency drives. Due to the increased use of power conversion units, new types of higher magnitude PDs have been observed to increase insulation degradation. By creating a cavity placed at different locations within the test object and exposing it to PWM voltage waveforms with two different rise times, a total of 345 660 PD events are recorded and organized into ten different classes. The maximum PD amplitude, duration, the time distance between consecutive PDs, and the area under the PD are used as features for PD classification. A unique way of concatenating a sequence of the extracted features to capture the temporal dependence of consecutive PDs is also presented. It is observed that when creating a sequence of information from consecutive observed PDs, a significant increase in classification accuracy can be obtained. Trained classifiers based on ensemble bagged decision trees (DTs) and long short-term memory (LSTM) architecture resulted in 95.3% and 98.5% average classification accuracy on test data respectively.

19 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
SKSarath Kumara
Sarath Kumara
XXXiangdong Xu
Xiangdong Xu
THThomas Hammarström
Thomas Hammarström
YOYingwei Ouyang
Yingwei Ouyang
Amir Masoud PourrahimiAmir Masoud Pourrahimi
Amir Masoud Pourrahimi
YSYuriy Serdyuk
Yuriy Serdyuk
To design reliable high voltage cables, clean materials with superior insulating properties capable of operating at high electric field levels at elevated temperatures are required. This study aims at the electrical characterization of a byproduct-free crosslinked copolymer blend, which is seen as a promising alternative to conventional peroxide crosslinked polyethylene currently used for high voltage direct current cable insulation. The characterization entails direct current (DC) conductivity, dielectric response and surface potential decay measurements at different temperatures and electric field levels. In order to quantify the insulating performance of the new material, the electrical properties of the copolymer blend are compared with those of two reference materials; i.e., low-density polyethylene (LDPE) and peroxide crosslinked polyethylene (XLPE). It is found that, for electric fields of 10–50 kV/mm and temperatures varying from 30 °C to 70 °C, the DC conductivity of the copolymer blend is in the range of 10−17–10−13 S/m, which is close to the conductivity of crosslinked polyethylene. Furthermore, the loss tangent of the copolymer blend is about three to four times lower than that of crosslinked polyethylene and its magnitude is on the level of 0.01 at 50 °C and 0.12 at 70 °C (measured at 0.1 mHz and 6.66 kV/mm). The apparent conductivity and trap density distributions deduced from surface potential decay measurements also confirmed that the new material has electrical properties at least as good as currently used insulation materials based on XLPE (not byproduct-free). Thus, the proposed byproduct-free crosslinked copolymer blend has a high potential as a prospective insulation medium for extruded high voltage DC cables.

17 December 2018 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
THThomas Hammarström
Thomas Hammarström
The benefits of employing multilevel pulsewidth-modulated (PWM) waveforms for diagnostic purposes compared to sinusoidal- and square-shaped voltages are presented in this paper. Examples on how the high voltage circuits are designed to enable these studies, as well as results, are discussed. To demonstrate the approach, it is investigated what influence the choice of PWM levels has on the partial discharge (PD) characteristics for two similar wire specimens insulated by different materials. Here, to resemble a motor winding, two different twisted pair test objects insulated by either pure polyamide-imid (PAI) material or with added conductive Cr₂O₃ material were exposed to voltages with ultrashort rise times. The test objects were fed from either two-, three-, five-, or seven-level inverter waveforms of similar shape as in actual applications. To compare the performances, measurements of the PD characteristics were conducted. Specifically, the total number of PDs, as well as their average maximum amplitude per cycle, was obtained together with the phase-resolved PD pattern for each case. The experimental results presented in this paper show that the total peak and summed PD magnitude (exposure) drop considerably more for the Cr₂O₃ insulation compared to PAI when applying a five-level or higher level inverter. This reduction is more significant for the insulation with added Cr₂O₃ material and the usage of higher inverter levels reveals this. As more information can be obtained using higher inverter levels, the evaluation of new material constitutions is preferably done utilizing at least a three-level inverter or higher.

4 June 2021 in Energies
Verified
Journal Article
Open access
PDF file
AKAnton Kersten
Anton Kersten
ARArtem Rodionov
Artem Rodionov
MKManuel Kuder
Manuel Kuder
THThomas Hammarström
Thomas Hammarström
ALAnton Lesnicar
Anton Lesnicar
TTTorbjörn Thiringer
Torbjörn Thiringer
Battery electric vehicles demand a wide variety of charging networks, such as charging stations and wallboxes, to be set up in the future. The high charging power (typically in the range of a couple of kW up to a couple of hundred kW) and the possibly long duration of the charging process (up to more than 24 h) put some special requirements on the electrical infrastructure of charging stations, sockets, and plugs. This paper gives an overview of the technical design requirements and considerations for vehicle charging stations, sockets, and plugs, including their infrastructure, according to the Swedish Standard 4364000, “Low-voltage electrical installations—Rules for design and erection of electrical installations”, and the corresponding harmonized European standards. In detail, the four internationally categorized charging modes are explained and the preferable charging plugs, including their two-bus communication, according to European Directives are shown. The dimensioning of the supply lines and the proper selection of the overcurrent protection device, the insulation monitor, and the residual current device are described. Furthermore, a comprehensive overview of the required safety measures, such as the application of an isolation transformer or the implementation of an overvoltage protection mechanism, and the limits for conducted electromagnetic emissions, such as low-frequency harmonics or high-frequency (150 kHz to 108 MHz) emissions, are given.

15 July 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
THThomas Hammarström
Thomas Hammarström
Ultra-short risetimes of voltage pulses utilized in modern power electronic-based control in combination with voltage overshoots may accelerate aging of electric motor insulation systems. The latter being aggravated by both connecting cable length and impedance mismatches within motor windings. To understand these phenomena better, the aim of the presented work is to demonstrate the influence of both these factors on the imposed by them partial discharge (PD) activity. A test technique is presented that allows creating controllable overshoots in bipolar PWM voltage waveforms of different rise times and experimentally exposing to them pigtail test objects that resemble the insulation of high voltage motor windings. It is demonstrated that the mutual interrelation between the DC peak voltage level and the oscillation magnitude influences the resulting stress considerably. The partial discharge extinction voltage level (PDEV) is particularly affected, and a notably increased stress is introduced on the insulation due to the presence of overshoots. It is thus implied that, when designing and performing accelerated aging tests, the possibility of appearing in them overshot stresses should be avoided, as their presence can yield erroneous conclusions in the evaluation of insulation material performance.

9 July 2024 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Antonino ImburgiaAntonino Imburgia
Antonino Imburgia
Giuseppe RizzoGiuseppe Rizzo
Giuseppe Rizzo
Guido AlaGuido Ala
Guido Ala
THThomas Hammarström
Thomas Hammarström
YSYuriy Serdyuk
Yuriy Serdyuk
Pietro RomanoPietro Romano
Pietro Romano
In this work, the role of the electric conductivity on variations of the PD phenomenon in XLPE insulation under DC stress is investigated and demonstrated. To enable this investigation, a new experimental setup simulating the insulating layer of a cable with an embedded air void defect and subjected to a DC stress and temperature has been proposed. The setup consists of two flat specimens connected in series. One of them is heated while the other one, that contains the defect, is kept at ambient temperature. Consequently, the electric fields induced by the externally applied DC stress differ between the two specimens. In this way, a conductivity variation between two dielectric layers is obtained. To facilitate the usage of this method, a new simulation model related to the proposed experimental setup has also been developed. The model is an extension of the three-capacitor model, in which variable resistors are introduced. Both simulation and experimental results indicate that the introduced discrete thermal gradient results in higher conductivity values and enhanced PD activity.