By combining the high selectivity of a gas chromatograph (GC) with the high sensitivity and decent selectivity of an ion mobility spectrometer (IMS), GC-IMS have become increasingly popular in many applications. However, most GC suffer from long analysis times. In contrast, an hyper-fast GC allows for extremely fast analysis in the tens of seconds while reaching comparably high resolution. In turn, coupling such hyper-fast GC with IMS requires sufficiently high repetition rate of recording full IMS spectra to resolve the short GC peaks. Therefore, we present a drift tube IMS with 100 Hz repetition rate. Key is a small effective detector volume combined with short drift length. Therefore, the ion source of the IMS combines a small reaction region with an extended field-switching ion shutter and optimized gas flows. To resolve even the shortest GC peaks with a full width at half maximum of 100 ms, a short drift length of just 41 mm was used, achieving a measurement time of 10 ms per spectrum and hence ten data points across the shortest GC peak. To avoid condensation of the sample, the entire IMS was heated isothermally to 120 °C. Despite short drift times and high temperatures, the IMS still reaches high resolving power of Rp = 60. The hyper-fast GC-IMS reaches low detection limits in the low ppbV range. For demonstration, ketone mixes and three different hop varieties were analyzed in <30 s.
Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional high-pass component in the GHz range. Due to the non-linear transfer function the measured signal differs from the original input signal. Here, we present an improved resistive voltage divider with additional compensation capacities to extend the linear bandwidth. With this new concept, the linear bandwidth is improved from 115 kHz to 88 MHz, while maintaining a DC input impedance of 10 MΩ. For high-voltage insulation and easy manufacturing, surface mounted resistors on a printed circuit board with a compensation electrode on the adjacent side are used. The performance of this resistive voltage divider is demonstrated by measuring a series of high-voltage pulses with an amplitude of 2.5 kVpeak-peak. The measured pulse rise time is about 16 ns, corresponding to an average slew-rate of 150 V/ns. Finally, the developed resistive voltage divider is successfully used to measure fast high-voltage transients required for advanced ion mobility spectrometers with integrated collision induced fragmentation.
One major challenge in detecting less volatile compounds with an ion mobility spectrometer (IMS) is preventing condensation of target molecules in the sampling line and ionization region to allow for fast response and recovery. Heating the entire device including the sampling line can of course mitigate condensation of such compounds, but this comes at the cost of reduced resolving power and compromised detection limits. Furthermore, a considerable amount of additional power and an IMS design with temperature-resistant components are needed. In this work, a different approach has been investigated, with a heated sample inlet in combination with a directed sample gas flow through the ionization region, but with the drift region at lower temperature. While this approach effectively addresses the issue of condensation, it results in an inhomogeneous temperature distribution within the drift region. Simulations and experimental data reveal that this uneven temperature distribution can significantly distort the peaks in the ion mobility spectrum, depending on the IMS orientation. However, positioning the IMS vertically, with the detector facing down, significantly minimizes temperature-induced peak distortion, thereby maintaining high resolving power. In this orientation, the IMS used in this work shows a resolving power of 80, while the IMS sample inlet and outlet are heated to 423 K. In addition, a directed sample gas flow in the ionization region is used to further reduce condensation in the ionization region. The approach and findings revealed in this work allow the construction of IMS with a heated sample inlet to prevent condensation of less volatile compounds while also maintaining the high resolving power of a drift tube at room temperature. The results on the influence of the orientation of the IMS can also be applied to even higher temperatures.
Electrical resonators are usually characterized by their resonance frequency, attenuation and quality factor. External quantities can affect these parameters, resulting in a characteristic change in the resonator, which can be used as a sensor effect. This work presents a new concept and electronic device for the continuous recording of resonator characteristics using single-sideband modulation. A test signal consisting of a center frequency and two sidebands is generated and the center frequency is set close to the resonator’s resonance frequency while the two sidebands are adjusted symmetrically around the center frequency. By exiting the resonator with the test signal and demodulating the resulting output into individual frequency components, a continuous measurement of the attenuation is possible. The center frequency is adjusted so that both sidebands have equal attenuation, resulting in a center frequency that corresponds to the resonance frequency of the resonator. If the resonator does not show a symmetrical frequency response, the sideband attenuation ratio can be adjusted accordingly. Continuous recording of the resonator characteristics at a sampling rate of 100 Sps was verified using a digitally tunable RLC series resonator with resonance frequencies between 250 MHz and 450 MHz, resulting in a maximum error below 1.5%.