Tim Kobelt

Tim Kobelt

Auto-generated profile, based on publicly available information

Tim Kobelt

Department of Sensors and Measurement Technology, Institute of Electrical Engineering and Measurement Technology, Leibniz University Hannover, Hannover, Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 July 2024 in Journal of the American Society for Mass Spectrometry
Verified
Journal Article
Open access
CSChristoph Schäfer
Christoph Schäfer
MAMaria Allers
Maria Allers
MHMoritz Hitzemann
Moritz Hitzemann
ANAlexander Nitschke
Alexander Nitschke
TKTim Kobelt
Tim Kobelt
SZStefan Zimmermann
Stefan Zimmermann
High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.

30 October 2024 in HardwareX
Verified
Journal Article
Open access
TKTim Kobelt
Tim Kobelt
MLMartin Lippmann
Martin Lippmann
ANAlexander Nitschke
Alexander Nitschke
LKLou Kielhorn
Lou Kielhorn
SZStefan Zimmermann
Stefan Zimmermann
Ion mobility spectrometers (IMS) are used in a wide variety of applications, including trace gas detection in safety and security applications, but also in more analytical applications, e.g., in medicine or food quality monitoring. Consequently, IMS are often coupled with other separation techniques and laboratory equipment, requiring synchronization between the external equipment and the IMS electronics. In addition, IMS and the associated electronics are becoming increasingly complex due to ongoing instrumental developments. In this work, we present an open source data acquisition hardware tailored to the requirements of advanced IMS, but also applicable to other applications. The data acquisition hardware provides trigger pulses for synchronized operation of the IMS ion gate or external devices. In addition, the data acquisition hardware allows for parallel digitalization using two isolated 16-bit analog-to-digital converters (ADC) with up to 250 kilosamples per second. The galvanically isolated trigger input ensures a synchronized start of the IMS measurements, particularly when connecting external instrumentation such as a gas chromatograph. Furthermore, due to the isolated ADCs, the hardware allows great flexibility in defining the ground potential of the instrument setup.

9 July 2024 in Renewable Energy
Verified
Journal Article
Open access
ANAlexander Nitschke
Alexander Nitschke
MHMoritz Hitzemann
Moritz Hitzemann
JWJonas Winkelholz
Jonas Winkelholz
TKTim Kobelt
Tim Kobelt
CTChristian Thoben
Christian Thoben
SZStefan Zimmermann
Stefan Zimmermann

13 November 2023 in Journal of Chromatography A
Verified
Journal Article
Closed access
TKTim Kobelt
Tim Kobelt
MLMartin Lippmann
Martin Lippmann
JWJannik Wuttke
Jannik Wuttke
HWHanno Wessel
Hanno Wessel
SZStefan Zimmermann
Stefan Zimmermann

30 May 2025 in Frontiers in Bioengineering and Biotechnology
Verified
Journal Article
Open access
PDF file
TKTim Kobelt
Tim Kobelt
JKJonas Klose
Jonas Klose
RMRumjhum Mukherjee
Rumjhum Mukherjee
MLMartin Lippmann
Martin Lippmann
SSSzymon P. Szafranski
Szymon P. Szafranski
SZStefan Zimmermann
Stefan Zimmermann
The rapid identification of bacterial pathogens is critical for the early diagnosis of severe clinical conditions, such as sepsis or implant-associated infections, and for the initiation of timely, targeted therapies. This need is particularly acute within the complex oral microbiome, where diverse opportunistic pathogens contribute to a range of local and systemic diseases. While techniques such as phenotypic systems and MALDI-TOF-MS offer faster results, they remain limited by costs, and operational constraints. To address these challenges and cater to the need for rapid identification of bacteria, we present a system for identification and classification of anaerobic bacteria as a first example. This system combines a pyrolyzer, a gas chromatograph and a highly sensitive ion mobility spectrometer. The ion mobility spectrometer has been optimized for coupling with the gas chromatograph and offers simultaneously recording of ion mobility spectra in both ion polarities during one gas chromatographic separation by using two drift tubes arranged in axial configuration. Feasibility has been demonstrated by building a database of fingerprints of eleven isolated reference samples of anaerobic bacteria with clinical relevance. Preliminary experiments have demonstrated that pattern recognition algorithms can predict the genus of isolated bacteria with a precision of up to 97%.

19 April 2025 in Analytica Chimica Acta
Verified
Journal Article
Open access
MLMartin Lippmann
Martin Lippmann
MHMoritz Hitzemann
Moritz Hitzemann
TSTimo Sawatzki
Timo Sawatzki
JWJonas Winkelholz
Jonas Winkelholz
ANAlexander Nitschke
Alexander Nitschke
SZStefan Zimmermann
Stefan Zimmermann
One major challenge in detecting less volatile compounds with an ion mobility spectrometer (IMS) is preventing condensation of target molecules in the sampling line and ionization region to allow for fast response and recovery. Heating the entire device including the sampling line can of course mitigate condensation of such compounds, but this comes at the cost of reduced resolving power and compromised detection limits. Furthermore, a considerable amount of additional power and an IMS design with temperature-resistant components are needed. In this work, a different approach has been investigated, with a heated sample inlet in combination with a directed sample gas flow through the ionization region, but with the drift region at lower temperature. While this approach effectively addresses the issue of condensation, it results in an inhomogeneous temperature distribution within the drift region. Simulations and experimental data reveal that this uneven temperature distribution can significantly distort the peaks in the ion mobility spectrum, depending on the IMS orientation. However, positioning the IMS vertically, with the detector facing down, significantly minimizes temperature-induced peak distortion, thereby maintaining high resolving power. In this orientation, the IMS used in this work shows a resolving power of 80, while the IMS sample inlet and outlet are heated to 423 K. In addition, a directed sample gas flow in the ionization region is used to further reduce condensation in the ionization region. The approach and findings revealed in this work allow the construction of IMS with a heated sample inlet to prevent condensation of less volatile compounds while also maintaining the high resolving power of a drift tube at room temperature. The results on the influence of the orientation of the IMS can also be applied to even higher temperatures.