A growing demand for low-cost gas sensors capable of detecting the smallest amounts of highly toxic substances in air, including chemical warfare agents (CWAs) and toxic industrial chemicals (TICs), has emerged in recent years. Ion mobility spectrometers (IMS) are particularly suitable for this application due to their high sensitivity and fast response times. In view of the preferred mobile use of such devices, miniaturized ion drift tubes are required as the core of IMS-based lightweight, low-cost, hand-held gas detectors. Thus, we evaluate the suitability of a miniaturized ion mobility spectrometer featuring an ion drift tube length of just 40 mm and a high resolving power of Rp = 60 for the detection of various CWAs, such as nerve agents sarin (GB), tabun (GA), soman (GD), and cyclosarin (GF), as well as the blister agent sulfur mustard (HD), the blood agent hydrogen cyanide (AC) and the choking agent chlorine (CL). We report on the limits of detection reaching minimum concentration levels of, for instance, 29 pptv for sarin (GB) within an averaging time of only 1 s. Furthermore, we investigate the effects of precursors, simulants, and other common interfering substances on false positive alarms.
4 April 2019 in International Journal for Ion Mobility Spectrometry
Developing powerful hand-held drift tube ion mobility spectrometers (IMS) requires small, lightweight drift tubes with high analytical performance. In this work, we present an easy-to-manufacture, miniaturized drift tube ion mobility spectrometer, which is manufactured from polyether ether ketone, stainless steel foils and printed circuit boards. It is possible to operate the drift tube IMS with a radioactive 3H ionization source or a non-radioactive X-ray ionization source with 3 kV acceleration voltage. The drift tube design provides high resolving power of Rp = 63 at a drift length of just 40 mm, 15 mm × 15 mm in cross-section (outer dimensions) and a drift voltage of 2.5 kV. The limits of detection for less than one second of averaging are 40 pptv for dimethyl-methylphosphonate and 30 pptv for methyl salicylate. For demonstration, the miniaturized drift tube IMS is integrated into a stand-alone battery-powered mobile device, including a closed gas-loop, high performance driver electronics and wireless data transmission. In a proof-of-concept study, this device was tested in an international field evaluation exercise to detect the release of a volatile, hazardous substance inside a large entry hall.
Rapidly detecting and identifying chemical agents after a chemical release is crucial for a reliable assessment of imminent risks and provides the initial basis for defining an adequate level of protection for first responders. A drone equipped with gas detectors may quickly explore the contaminated area without exposing any first responders to the yet unknown threat. However, drones possess limitations in their capability concerning payload, operational range, and power requirements. Choosing the appropriate gas sensors for this application, thus, imposes significant technical challenges. In this work, we present a mobile ion mobility spectrometer (IMS) designed for operation with drones. The IMS is equipped with a dedicated closed gas loop, high-performance driver electronics, and wireless data transmission capabilities. The resulting performance of the UAV-mounted mobile IMS is characterized in the lab with the chemical warfare agents (CWAs) sarin (GB), tabun (GA), soman (GD), cyclosarin (GF), and sulfur mustard (HD), and further evaluated in three different field-testing scenarios using the simulation compound di(propylene glycol) methyl ether (DPM). It is thereby used to monitor the area near (i) a point source continuously emitting small quantities of a gaseous chemical, (ii) a point source suddenly releasing a limited quantity of a chemical as an aerosol, and (iii) a minor contamination of a liquid chemical on the ground. The results obtained in this work enable a well-founded estimation of the capabilities and limitations of the drone-mounted mobile IMS concerning the real-time remote detection of chemical hazards such as CWAs.
7 May 2020 in International Journal for Ion Mobility Spectrometry
The drift voltage required for operating ion mobility spectrometers implies high voltage isolation of either the ion source or the detector. Typically, the detector is grounded due to the sensitivity of the small ion currents to interferences and thus higher requirements for signal integrity than the ion source. However, for certain ion sources, such as non-radioactive electron emitters or electrospray ionization sources, or for coupling with other instruments, such as gas or liquid chromatographs, a grounded ion source is beneficial. In this paper, we present an isolated data acquisition interface using a 16 bit, 250 kilosamples per second analog to digital converter and fiber optic transmitters and receivers. All spectra recorded via this new data acquisition interface and with a grounded ion source show the same peak shapes and noise when compared with a grounded detector, allowing additional freedom in design.