High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) ionize and separate ions at reduced pressures of 10-40 mbar and over a wide range of reduced electric field strengths E/N of up to 120 Td. Their reduced operating pressure is distinct from that of conventional drift tube ion mobility spectrometers that operate at ambient pressure for trace compound detection. High E/N can lead to a field-induced fragmentation pattern that provides more specific structural information about the analytes. In addition, operation at high E/N values adds the field dependence of ion mobility as an additional separation dimension to low-field ion mobility, making interfering compounds less likely to cause a false positive alarm. In this work, we study the chemical warfare agents tabun (GA), sarin (GB), soman (GD), cyclosarin (GF) and sulfur mustard (HD) in a HiKE-IMS at variable E/N in both the reaction and the drift region. The results show that varying E/N can lead to specific fragmentation patterns at high E/N values combined with molecular signals at low E/N. Compared to the operation at a single E/N value in the drift region, the variation of E/N in the drift region also provides the analyte-specific field dependence of ion mobility as additional information. The accumulated data establish a unique fingerprint for each analyte that allows for reliable detection of chemical warfare agents even in the presence of interfering compounds with similar low-field ion mobilities, thus reducing false positives.
By combining the high selectivity of a gas chromatograph (GC) with the high sensitivity and decent selectivity of an ion mobility spectrometer (IMS), GC-IMS have become increasingly popular in many applications. However, most GC suffer from long analysis times. In contrast, an hyper-fast GC allows for extremely fast analysis in the tens of seconds while reaching comparably high resolution. In turn, coupling such hyper-fast GC with IMS requires sufficiently high repetition rate of recording full IMS spectra to resolve the short GC peaks. Therefore, we present a drift tube IMS with 100 Hz repetition rate. Key is a small effective detector volume combined with short drift length. Therefore, the ion source of the IMS combines a small reaction region with an extended field-switching ion shutter and optimized gas flows. To resolve even the shortest GC peaks with a full width at half maximum of 100 ms, a short drift length of just 41 mm was used, achieving a measurement time of 10 ms per spectrum and hence ten data points across the shortest GC peak. To avoid condensation of the sample, the entire IMS was heated isothermally to 120 °C. Despite short drift times and high temperatures, the IMS still reaches high resolving power of Rp = 60. The hyper-fast GC-IMS reaches low detection limits in the low ppbV range. For demonstration, ketone mixes and three different hop varieties were analyzed in <30 s.
Ion mobility spectrometers (IMS) are used in a wide variety of applications, including trace gas detection in safety and security applications, but also in more analytical applications, e.g., in medicine or food quality monitoring. Consequently, IMS are often coupled with other separation techniques and laboratory equipment, requiring synchronization between the external equipment and the IMS electronics. In addition, IMS and the associated electronics are becoming increasingly complex due to ongoing instrumental developments. In this work, we present an open source data acquisition hardware tailored to the requirements of advanced IMS, but also applicable to other applications. The data acquisition hardware provides trigger pulses for synchronized operation of the IMS ion gate or external devices. In addition, the data acquisition hardware allows for parallel digitalization using two isolated 16-bit analog-to-digital converters (ADC) with up to 250 kilosamples per second. The galvanically isolated trigger input ensures a synchronized start of the IMS measurements, particularly when connecting external instrumentation such as a gas chromatograph. Furthermore, due to the isolated ADCs, the hardware allows great flexibility in defining the ground potential of the instrument setup.
Besides safety and security applications, ion mobility spectrometry (IMS) is increasingly used in other fields such as medicine, environmental monitoring and food quality analysis. However, some applications require gas chromatographic separation before analysis by IMS. Furthermore, different compounds in the sample may form positive or negative ions during ionization and therefore simultaneous detection of both ion polarities is highly beneficial to avoid two chromatographic runs of the same sample. This can be achieved by ultra-fast polarity switching of a single drift tube IMS, allowing for quasi-simultaneous detection of both ion polarities. By using a ramped aperture voltage during the switching process, we overcome the issue of excessive displacement currents at the detector during polarity switching, which usually lead to overdriving the output signal of the high-gain transimpedance amplifier. Furthermore, mechanical aperture grid oscillations caused by polarity switching were also reduced through the ramped aperture voltage. This enables a polarity switching time of only 7 ms at a drift voltage of 8 kV and a drift length of 103 mm, leading to a high resolving power of RP = 117. Requiring 50 ms to acquire a pair of positive and negative spectrum, the IMS achieves an acquisition rate of 20 Hz. It reaches limits of detection of 20 pptv for dimethyl methylphosphonate and 40 pptv for methyl salicylate. For demonstration, different hop varieties were investigated and could be clearly differentiated by considering both, the positive and negative spectra.
For various applications, such as gate drivers for transistors, wireless chargers for mobile devices and cars, and isolated measurement equipment, an isolated DC power supply for electronic components is required. In this work, a new concept for an isolated power supply with insulation strength of 50 kV and power transmission of up to 60 W to supply measurement equipment with 12 or 24 V is presented. Furthermore, high overall efficiency of 82.5% at 55 W is achieved. Feasibility is demonstrated in a real application powering data acquisition electronics at high reference potential. Our new concept uses a coreless printed circuit board (PCB) transformer (15 cm × 10 cm × 4 cm and a weight of 480 g) designed for maximum efficiency via a coil layout and close proximity of adjacent coils on one PCB while reaching high isolation strength via the PCB material and potted coils. To increase efficiency, we investigated different coil geometries at different frequencies. A low-cost design consisting of two Qi charging coils mounted on one PCB is compared with our integrated PCB transformers manufactured from a four-layer PCB with ferrites applied on the outside. With this new design, high isolation voltages are possible while reaching high transformer efficiency of up to 90%.
Resistive voltage dividers tend to have a highly non-linear transfer function as parasitic and stray capacitances exert an increasing influence with increasing frequency. The non-linear transfer function depends on the topology and resistors used and consists of a low-pass filter with an additional high-pass component in the GHz range. Due to the non-linear transfer function the measured signal differs from the original input signal. Here, we present an improved resistive voltage divider with additional compensation capacities to extend the linear bandwidth. With this new concept, the linear bandwidth is improved from 115 kHz to 88 MHz, while maintaining a DC input impedance of 10 MΩ. For high-voltage insulation and easy manufacturing, surface mounted resistors on a printed circuit board with a compensation electrode on the adjacent side are used. The performance of this resistive voltage divider is demonstrated by measuring a series of high-voltage pulses with an amplitude of 2.5 kVpeak-peak. The measured pulse rise time is about 16 ns, corresponding to an average slew-rate of 150 V/ns. Finally, the developed resistive voltage divider is successfully used to measure fast high-voltage transients required for advanced ion mobility spectrometers with integrated collision induced fragmentation.