Innovation Center for Precision Measurement Apparatus and Instrument, Hangzhou Extremely Weak Magnetic Field Major Science and Technology Infrastructure Research Institute, Hangzhou 310051, China
Dr. Bo Li
Innovation Center for Precision Measurement Apparatus and Instrument, Hangzhou Extremely Weak Magnetic Field Major Science and Technology Infrastructure Research Institute, Hangzhou 310051, China
Compact atomic magnetometer has become an important approach for noise measurement of magnetic shielding systems as well as biomagnetic measurement. In this study, we propose a novel method that enables time-shard triaxial magnetic field measurements in near-zero magnetic field through a compact high-performance atomic magnetometer with femtotesla sensitivity. With pump–probe orthogonal configuration, the magnetometer can be operated without optical and magnetic modulation. The y -axis magnetic field measurement was realized in zero field, whereas the x - and z - axes magnetic fields were measured by the cross-application of the bias magnetic fields operating in near-zero field. The maximum response amplitude and sensitivity with bandwidths of 46.8 Hz ( x - axis), 10.5 Hz ( y -axis), and 10.9 Hz ( z -axis) are achieved under bias magnetic fields of $B_{z-\mathrm {offset}}= 8$ nT and $B_{x-\mathrm {offset}} = 2$ nT. The bandwidth along x - axis was extended to 232 Hz under $B_{z-\mathrm {offset}} = 32$ nT, which can further be improved by increasing $B_{z-\mathrm {offset}}$ . The linear interval of measurable magnetic field are between −11.7 to +11.7 nT ( x - axis), −0.8 to +0.8 nT ( y -axis), and −28.2 to +28.2 nT ( z -axis). For x - and z -axes, the measurable interval can further be improved by increasing $B_{z-\mathrm {offset}}$ and $B_{x-\mathrm {offset}}$ , respectively. The triaxial sensitivities achieved through our method reached 3.1 ± 0.3 fT/Hz 1/2 ( x - axis), 2.0 ± 0.1 fT/Hz 1/2 ( y - axis), and 6.0 ± 0.5 fT/Hz 1/2 ( z - axis). This system is measured in a low-noise ferrite magnetic shield to ensure extra-low magnetic noise condition. Furthermore, the non-modulation triaxial vector operation demonstrated in this study is advantageous for reducing interference and spin-exchange relaxation caused by magnetic field modulation.
The emerging multi-channel spin-exchange relaxation-free (SERF) atomic magnetometer is a promising candidate for non-intrusive biomagnetism imaging. In this study, we propose a scanning 9-channel SERF magnetometer based on an acousto-optic modulator (AOM). Using the diffraction light of the AOM as the probe laser (with a low laser power of 1.7 mW), 9 channels were rapidly scanned by altering the diffraction angle. The scanning imaging scheme provides a new, to the best of our knowledge, approach for multi-channel magnetic field measurement and realizes a single-channel sensitivity of about 3 fT/Hz1/2, a spatial resolution of 0.6 mm, and a time resolution of about 2.7 ms, which is well suited for real-time extremely weak magnetic field imaging.
16 September 2024 in IEEE Transactions on Instrumentation and Measurement
Miniaturized high-sensitivity atomic magnetometers play a crucial role in biomagnetic measurements. The utilization of multipass cells enhances the sensitivity of atomic magnetometers. This study explores the benefits of employing a multipass cell in spin-exchange relaxation-free (SERF) atomic magnetometers through theoretical and experimental analysis. A signal-to-noise ratio (SNR) model was established by accounting for the optimal detuning frequency of the probe light and low-frequency 1/f noise. This enabled the optimal number of probe light passes through the vapor cell to be determined. Additionally, compact and symmetric reflective optical paths were designed to mitigate polarization gradients in atomic magnetometers with high atomic number density. Experimental results confirmed that the magnetic field sensitivity of the triple-pass configuration (1.8 fT/Hz $^{1/2}$ ) was 1.89 times that of the single-pass configuration (3.4 fT/Hz $^{1/2}$ ), consistent with the theoretical analysis. This study provides valuable theoretical guidance for analyzing the SNR performance of SERF atomic magnetometers and demonstrates the potential of multipass cells in enhancing their magnetic field sensitivity. The utilization of multipass cells presents a viable approach toward the realization of highly sensitive and portable miniaturized SERF atomic magnetometers.
9 October 2023 in IEEE Transactions on Instrumentation and Measurement
The multi-channel optically-pumped magnetometer (OPM) system can experience crosstalk between adjacent sensors owing to the magnetic field generated by the magnetic coil. To mitigate this issue, this study proposes a design for a self-shielded biplanar coil assembly with a miniaturized structure, utilizing the target field method (TFM). Our approach involves setting different interplane spacings between each pair of planar coils to achieve high uniformity in all three axes. To further improve the field homogeneity and self-shielding effect, the particle swarm optimization with linearly decreasing inertia weight (LDW-PSO) is introduced into TFM to design self-shielded coils. This method reduces dependence on the position distribution of target points. Our results indicate that the maximum absolute value of field relative inhomogeneity errors of Bx and Bz are 14.4% and 10.0%, respectively. Furthermore, the maximum absolute value of external relative field at 16 mm from the center is approximately 1%, meaning that the influence of crosstalk can be ignored.
We introduce a novel, to the best of our knowledge, compact multipass cell design for spin-exchange relaxation-free (SERF) atomic magnetometers, replacing conventional reflective cavities with a dual-parallel plate configuration. This adjustable planar reflector setup achieves precise control of reflection optical paths and dramatically enhances signal response, resolving the complexity of cavity design and volume increase caused by multiple reflectors in existing schemes, while having high-temperature adaptability and minimizing size and complexity. Additionally, combined with a flat-top light pump to boost atomic polarization uniformity, our system achieves 1 fT/Hz½ sensitivity, delivering 260% improvement in signal and 200% in sensitivity over conventional designs. This streamlined, high-temperature-compatible architecture marks a significant step toward scalable, next-generation quantum sensors that unite exceptional sensitivity with practical miniaturization.
5 March 2025 in IEEE Transactions on Instrumentation and Measurement
High-shielding coefficient and low-noise magnetic shielding systems play an important role in the field of ultrahigh-sensitive magnetic field sensors and biomagnetism measurements. Currently, the magnetic shielding systems often suffer from high intrinsic magnetic noise generated by μ-metal. In this study, cobalt-based metallic glass with high permeability and excellent soft magnetic properties was employed to design magnetic shielding cylinders with an inner diameter of 240 mm. Using the Finite Element Method simulation, the shielding coefficient S of the single-layer cobalt-based metallic glass (20 μm thickness) magnetic shielding cylinder was 11.27 for the geomagnetic field. The magnetic noise characteristics of cobalt-based metallic glass magnetic shielding cylinder were analyzed based on complex permeability and resistivity in the obtained frequency band. In addition, we also experimentally studied the effectiveness of cobalt-based metallic glass magnetic shielding cylinder with different layers, when used as the innermost magnetic shielding layer, in suppressing the magnetic noise generated by μ-metal. The experimental results show that the minimum magnetic noise of the ten-layer cobalt-based metallic glass magnetic shielding cylinder is only 1.3 fT/Hz1/2, which indicates that cobalt-based metallic glass as an innermost magnetic shielding layer material can effectively reduce the magnetic noise generated by μ-metal and verifies the superiority of cobalt-based metallic glass in achieving low noise. Moreover, the ultra-thin structure and low cost of the cobalt-based metallic glass magnetic shielding cylinder offer significant advantages for other applications requiring the measurement of extremely weak magnetic fields. This study confirms the potential of cobalt-based metallic glass in improving the performance of magnetic shielding systems.