As part of the experiments herein, the mechanical properties of specimens made of poly-ether-ether-ketone (PEEK) material using 3D printing technology were determined. Two populations of specimens were investigated, the first of which contained an amorphous structure, while the other held a crystal structure. The studies also investigated the influence of the print directionality on the mechanical properties obtained. Static tensile, three-point bending, and impact tests were carried out. The results for the effect of the structure type on the tensile properties showed that the modulus of elasticity was approximately 20% higher for the crystal than for the amorphous PEEK form. The Poisson’s ratios were similar, but the ratio was slightly higher for the amorphous samples than the crystalline ones. Furthermore, the studies included a chemical PEEK modification to increase the hydrophilicity. For this purpose, nitrite and hydroxyl groups were introduced into the chain by chemical reactions. The results demonstrate that the modified PEEK specimens had worse thermoplastic properties than the unmodified specimens.
This study investigated how spatial projection systems influences body balance including postural stability. Analyzing precisely defined frequency bands of movements of the center of pressure makes it possible to determine the effectiveness of the balance system’s response to disruptions and disorders and may be used as an indicator in the diagnosis of motor dysfunction. The study involved 28 participants for whom the center of pressure was assessed in a test with open eyes, closed eyes and with virtual reality projection. Percent distributions of energy during wavelet decomposition were calculated. Changes in body stability were determined for the virtual reality tests and these changes were classified as an intermediate value between the open-eyes test and the closed-eyes test. The results indicate the importance of using safety support systems in therapies involving Virtual Reality. The results also show the necessity of measurements times in stabilographic evaluations in order to conduct a more thorough analysis of very low frequencies of the center of pressure signal.
This work aimed to assess the impact of acellularization and sterilization methods on the mechanical properties of biocomposites used as a skin substitute. On the basis of the statistical analysis, it was ascertained that the values of the Young modulus for the samples before the sterilization process—only in the cases of substances such as: trypsin, 15% glycerol and dispase—changed in a statistically significant way. In the case of dispase, the Young modulus value before the sterilization process amounted to 66.6 MPa, for trypsin this value equalled 33.9 MPa, whereas for 15% glycerol it was 11 MPa. In the case of samples after the completion of the sterilization process, the analysis did not show any statistically significant differences between the obtained results of Young’s modulus depending on the respective reagents applied. It was confirmed that different methods of acellularization and the process of sterilization effect the alteration of mechanical properties of allogeneic skins. In the case of the decellularization method using SDS (Sodium Dodecyl Sulfate), liquid nitrogen and 85% glycerol the highest values of strain were observed. In the authors’ opinion, it is the above-mentioned methods that should be recommended in the process of preparation of skin substitutes.
2 August 2023 in Journal of NeuroEngineering and Rehabilitation
Background: Balance disorders in patients diagnosed with Parkinson’s disease (PD) are associated with a change in balance-keeping strategy and reflex disorders which regulate the maintenance of vertical body posture. Center of foot pressure (COP) displacement signals were analyzed during quiet standing experiments to define such changes. The research aimed to apply stock exchange indices based on the trend change analyses to the assessment of a level of the Parkinson disease progression on the grounds of the analysis of the COP signals. Methods: 30 patients in two stages of PD, 40 elderly participants, and 20 individuals at a young age were studied. Each person was subjected to 3 measurements with open and closed eyes. A technical analysis of the COP displacement signal was performed, and the following quantities were determined: indices related to the number of trend changes (TCI), indices defining a mean time (TCI_dT), and mean displacement (TCI_dS) and mean velocity (TCI_dV) between such changes. Results: The results indicate a higher TCI value for PD than for aged-matched control group (p < 0.05). In the case of PD patients, there was also an increase in the TCI_dS value by 2–5 mm, which mainly contributed to the increase in TCI_dV. Statistically significant differences for the TCI_dT values occurred between all groups in which differences in the average COP velocity were noted. Conclusions: The TCI and TCI_dV results obtained for the healthy participants enabled the development of indices supporting PD diagnostics. The causes of the TCI_dV changes in patients were determined, i.e., whether they resulted from an increase in the TCI_dT or TCI_dS between the moments of trend changes indicated by the developed algorithm. The developed methodology provides new information on the impact of PD on the strategy of maintaining balance, which was impossible to obtain using currently used analyses. Trial registration The conducted research is an observational study and does not include a health care intervention. Participants gave their consent to participate in the research and the procedure was approved by the Institutional Bioethics Committee.
Purpose: This work aimed to develop a novel indicator of upper limb manipulative movements. A principal component analysis (PCA) algorithm was applied to kinematic measurements of movements of the upper limbs performed during an everyday activity. Methods: Kinematics of the upper limb while drinking from a mug were investigated using the commercially available Xsens MVN BIOMECH inertial sensor-based motion capture system. The study group consisted of 20 male patients who had previously suffered an ischaemic stroke, whilst the reference group consisted of 16 males with no disorders of their motor organs. Based on kinematic data obtained, a set of 30 temporal and kinematic parameters were defined. From this, 16 parameters were selected for the determination of a novel indicator, the Upper Body Index (UBI), which served the purpose of assessing manipulative movements of upper limbs. Selection of the 16 parameters considered the percentage distribution of the parameters beyond the standard, the differences in mean values between the reference group and the study group, and parameter variability. Results: Analysis of kinematics allowed for the identification and selection of the parameters used in the development of the new index. This included 2 temporal parameters and 14 kinematic parameters, with the minimum and maximum angles of the upper limb joints, motion ranges in the joints, and parameters connected with movement of the spine recorded. These parameters were used to assess motion in the shoulder and elbow joints, in all possible planes, as well as spine movement. The values of the UBI indicator were as follows: in the case of the reference group: 13.67 ± 2.40 for the dominant limb, 13.71 ± 3.36 for the non-dominant limb; in the case of the stroke patient group: 130.86 ± 75.07 for the dominant limb, 155.58 ± 170.76 for the non-dominant limb. Conclusions: The developed UBI made it possible to discover deviations from the standard performance of upper limb movements. Therefore, the index may be applicable to the analysis of any sequence of movements carried out by the upper limb.
The influence of dynamic loads resulting from human motor activity and electrocorrosion inside the human body on the strength parameters of artificial joint elements has not yet been investigated. Hip joint arthroplasty is the most common surgical procedure in the world that allows doctors to remove pain and restore motor skills in people with severe hip diseases, after accidents, and in the elderly. Based on the reports, this article assesses changes in the number of implanted endoprostheses in the years 2005–2019 and determines the trends and estimated changes in the number of implanted hip prostheses in the following decades. The study assesses changes in selected strength parameters of UHMW-PE polyethylene inserts of hip joint endoprostheses during their use in the human body. The research was carried out on appropriately collected samples from UHMW-PE cups removed from the human body with a known history and lifetime from 4 to 10 years. Patients’ body weight ranged from 735 [N] to 820 [N], and the declared physical activity was similar in the entire research group. As part of the research, the values of changes in dynamic modules and the mechanical loss coefficient were determined in relation to the share of the crystalline and amorphous phases of artificial UHMW-PE cups, removed from the human body after different periods of exploitation under similar operating conditions. The analysis of selected strength parameters was performed at a temperature of 40 °C, which corresponds to the working conditions inside the human body. On the basis of numerical studies, the influence of changes in material parameters on the deformation of the artificial acetabulum during the patient’s motor activity, which is one of the causes of fatigue destruction, was determined.