Since modern power systems are susceptible to undesirable frequency oscillations caused by uncertainties in renewable energy sources (RESs) and loads, load frequency control (LFC) has a crucial role to get these systems’ frequency stability back. However, existing LFC techniques may not be sufficient to confront the key challenge arising from the low-inertia issue, which is due to the integration of high-penetration RESs. Therefore, to address this issue, this study proposes an optimized intelligent fractional-order integral (iFOI) controller for the LFC of a two-area interconnected modern power system with the implementation of virtual inertia control (VIC). Here, the proposed iFOI controller is optimally designed using an efficient metaheuristic optimization technique, called the gray wolf optimization (GWO) algorithm, which provides minimum values for system frequency deviations and tie-line power deviation. Moreover, the effectiveness of the proposed optimal iFOI controller is confirmed by contrasting its performance with other control techniques utilized in the literature, such as the integral controller and FOI controller, which are also designed in this study, under load/RES fluctuations. Compared to these control techniques from the literature for several scenarios, the simulation results produced by the MATLAB software have demonstrated the efficacy and resilience of the proposed optimal iFOI controller based on the GWO. Additionally, the effectiveness of the proposed controller design in regulating the frequency of interconnected modern power systems with the application of VIC is confirmed.
This study investigates the application of the model predictive control (MPC) approach for voltage stability of an isolated hybrid wind–diesel generation system based on reactive power control. This scheme consists of a synchronous generator (SG) for a diesel‐generator (DG) system and an induction generator (IG) for a wind energy conversion system. A static voltage automatic regulator (VAR) compensator (SVC) is connected at terminal bus to stabilise load voltage through compensating of reactive power. Two control paths are used to stabilise load bus voltage based on MPC. The first one by controlling the total reactive power of the system that by controlling the SVC firing angle and hence the load voltage. The second control path by controlling the SG excitation voltage and hence the load bus terminal voltage. The MPC is used to determine the optimal control actions including system constraints. To mitigate calculations effort and to reduce numerical problems, especially in large prediction horizon, an exponentially weighted functional MPC (FMPC) is applied. The proposed controller has been tested through step change in load reactive power plus step increase in input wind power. Also, the performance of the system with FMPC was compared with the classical MPC. Moreover, this scheme is tested against the parameters variations.
Distribution system planners and operators have increasingly exposed great attention to maximizing the penetration of renewable energy resources (RERs), and electric vehicles (EVs) toward modern microgrids. Accordingly, intensive operational and economic problems are expected in such microgrids. Specifically, the operators need to meet the increased demand for EVs and increase the dependence on RERs. The charging strategy for EVs and the RER penetration level may result in increased power loss, thermal loading, voltage deviation, and overall system cost. To address these concerns, this paper proposed an optimal planning approach for allocating EV charging stations with controllable charging and hybrid RERs within multi‐microgrids, where the charging strategy in the proposed planning approach contributed to improving power quality and overall system cost, where the voltage deviation, energy not supplied, total cost have been reduced to 26.03%, 49.57%, and 70.45%, respectively. The simulation results are compared with different optimization techniques to verify the effectiveness of the proposed algorithm. The proposed simultaneous allocation approach of EV charging stations and RERs can reduce operating costs for RERs and conventional stations while increasing the charging stations' capacity.
This article focuses on the energy-saving of each driving distance for battery electric vehicle (BEV) applications, by developing a more effective energy management strategy (EMS), under different driving cycles. Fuzzy logic control (FLC) is suggested to control the power management unit (PMU) for the battery management system (BMS) for BEV applications. The adaptive neural fuzzy inference system (ANFIS) is a modeling technique that is mainly based on data. Membership functions and FLC rules can be improved by simply training the ANFIS with real driving cycle data gathered from the MATLAB/SIMULINK program. Then, FLC console blocks are rewritten by enhanced membership functions by ANFIS traineeship. Two different driving cycles are chosen to check the improvement in the efficiency of this proposed system. The suggested control system is validated by simulation and comparison with the traditional proportional-integral (PI) control. The optimized FLC shows better energy-saving.
Recently, hybrid wind/PV microgrids have gained great attention all over the world. It has the merits of being environmentally friendly, reliable, sustainable, and efficient compared to its counterparts. Though there has been great development in this issue, the control and energy management of these systems still face challenges. The source of those challenges is the intermittent nature of both wind and PV energy. On the other hand, a new intelligent control technique called Brain Emotional Learning-Based Intelligent Controller (BELBIC) has garnered more interest. This paper proposes the control and energy management of hybrid wind/PV microgrids using a BELBIC controller. To design the system, simple power and energy analyses were proposed. The proposed microgrid was modeled and simulated using MATLAB. The responses of the energy system were tested under two different types of disturbances, namely step and ramp disturbances. These disturbances are applied to the wind speed, the irradiation level of the PV, and the load power. The results indicate that the AC load voltage and frequency are steady with negligible transients against the previous disturbance. In addition, the performance is better than that of the classical PI controller. Also, energy management acts perfectly to compensate for the intermittence and disturbances of the wind and PV energies. On the other hand, the system robustness against model parameters uncertainties in the microgrid parameters are studied.
This paper investigates how to increase the efficiency of a photovoltaic/energy storage generation unit supplying dynamic loads by regulating and managing both the photovoltaic generator and the storage battery charge-discharge modes. The proposed photovoltaic/energy storage unit is proposed to supply an induction motor driven industrial pump with controlled speed and/or a DC motor driven water pump. An optimal proportional-integral-derivative control based on an Artificial Bee Colony Optimization algorithm is used to regulate the photovoltaic generator in case of normal operation or in case of maximum power point tracking (MPPT) and to also control the battery storage charge discharge modes. A vector control based on the proposed optimal control is used to regulate the induction motor rotor speed at its low reference values needed by the industrial pump. First, a total model of the entire system is obtained. The controller performance with the proposed system is studied with both a DC motor and/or induction motor loads. Simulation results show that the proposed photovoltaic/storage generator is able to supply the suggested dynamic loads under different conditions and with good performance. Also, it is noticed that operating the photovoltaic base on maximum power point tracking condition will give about 43% extra generation power than the normal operation case.