Stefano Bianchi

Dr. Stefano Bianchi

Cardiology Division, Arrhythmology Unit, S. Giovanni Calibita Hospital, Isola Tiberina, 00186 Rome, Italy

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2024 in Nature Medicine
Verified
Journal Article
Open access
PDF file
EEEmmanuel Ekanem
Emmanuel Ekanem
PNPetr Neuzil
Petr Neuzil
TRTobias Reichlin
Tobias Reichlin
JKJoseph Kautzner
Joseph Kautzner
PVPepijn van der Voort
Pepijn van der Voort
VRVivek Y. Reddy
Vivek Y. Reddy
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.

28 December 2023 in EP Europace
Verified
Journal Article
Open access
PDF file
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
LMLorenzo Marcon
Lorenzo Marcon
MMMichele Magnocavallo
Michele Magnocavallo
Roberto MenèRoberto Menè
Roberto Menè
LPLuigi Pannone
Luigi Pannone
MMMark La Meir
Mark La Meir
Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan–Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.

22 March 2024 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
SMSchiavone Marco
Schiavone Marco
FSFrancesco Solimene
Francesco Solimene
MMMassimo Moltrasio
Massimo Moltrasio
Michela CasellaMichela Casella
Michela Casella
SBStefano Bianchi
Stefano Bianchi
CTClaudio Tondo
Claudio Tondo
Introduction: Limited data exist on pulsed‐field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI).Methods: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM‐PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared.Results: Among 249 patients, 21.7% had long‐standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin‐to‐skin times (PVI‐only 68 [60−90] vs. PVI + LAPWI 70 [59−88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D‐mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh‐density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow‐up of 273 [191–379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90‐day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies.Conclusion: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real‐world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy‐only method and does not significantly extend overall procedural times.

14 April 2009 in Pacing and Clinical Electrophysiology
Verified
Journal Article
Closed access
PDF file
SBStefano Bianchi
Stefano Bianchi
RRRenato P. Ricci
Renato P. Ricci
FBFrancesco Biscione
Francesco Biscione
FSFabrizio Sgreccia
Fabrizio Sgreccia
NBNatale DI Belardino
Natale DI Belardino
APAndrea Puglisi
Andrea Puglisi

Verified
Journal Article
Open access
PDF file
FLFrancesca Di Lorenzo
Francesca Di Lorenzo
EMEnrica Marchionni
Enrica Marchionni
VFValentina Ferradini
Valentina Ferradini
ALAndrea Latini
Andrea Latini
Laura PezzoliLaura Pezzoli
Laura Pezzoli
Federica SangiuoloFederica Sangiuolo
Federica Sangiuolo
Variants in desmoplakin gene (DSP MIM *125647) have been usually associated with Arrhythmogenic Cardiomyopathy (ACM), or Dilated Cardiomyopathy (DCM) inherited in an autosomal dominant manner. A cohort of 18 probands, characterized as heterozygotes for DSP variants by a target Next Generation Sequencing (NGS) cardiomyopathy panel, was analyzed. Cardiological, genetic data, and imaging features were retrospectively collected. A total of 16 DSP heterozygous pathogenic or likely pathogenic variants were identified, 75% (n = 12) truncating variants, n = 2 missense variants, n = 1 splicing variant, and n = 1 duplication variant. The mean age at diagnosis was 40.61 years (IQR 31–47.25), 61% of patients being asymptomatic (n = 11, New York Heart Association (NYHA) class I) and 39% mildly symptomatic (n = 7, NYHA class II). Notably, 39% of patients (n = 7) presented with a clinical history of presumed myocarditis episodes, characterized by chest pain, myocardial enzyme release, 12-lead electrocardiogram abnormalities with normal coronary arteries, which were recurrent in 57% of cases (n = 4). About half of the patients (55%, n = 10) presented with a varied degree of left ventricular enlargement (LVE), four showing biventricular involvement. Eleven patients (61%) underwent implantable cardioverter defibrillator (ICD) implantation, with a mean age of 46.81 years (IQR 36.00–64.00). Cardiac magnetic resonance imaging (CMRI) identified in all 18 patients a delayed enhancement (DE) area consistent with left ventricular (LV) myocardial fibrosis, with a larger localization and extent in patients presenting with recurrent episodes of myocardial injury. These clinical and genetic data confirm that DSP-related cardiomyopathy may represent a distinct clinical entity characterized by a high arrhythmic burden, variable degrees of LVE, Late Gadolinium Enhancement (LGE) with subepicardial distribution and episodes of myocarditis-like picture.

23 November 2024 in EP Europace
Verified
Journal Article
Open access
PDF file
GVGiampaolo Vetta
Giampaolo Vetta
DRDomenico Giovanni. Della Rocca
Domenico Giovanni. Della Rocca
APAntonio Parlavecchio
Antonio Parlavecchio
MMMichele Magnocavallo
Michele Magnocavallo
ASAntonio Sorgente
Antonio Sorgente
GCGian Battista Chierchia
Gian Battista Chierchia
Pulsed field ablation (PFA) is an innovative technology recently adopted for the treatment of atrial fibrillation (AF). Preclinical and clinical studies have reported a remarkable safety profile, as a result of its tissue specific effect targeting cardiomyocytes and sparing adjacent tissues. Single-shot pentaspline system was the first PFA device to receive regulatory approval. We performed a meta-analysis to compare the efficacy and safety of PFA with the single-shot pentaspline system versus currently available 2nd/3rd/4th generation Cryoballoon technologies (CRYO). We systematically searched electronic databases for studies focusing on AF ablation employing the PFA single-shot pentaspline system or 2nd/3rd/4th generation CRYO technologies. The primary endpoints were acute procedural success assessed on a vein and patient basis. Safety endpoints included overall periprocedural complications and major periprocedural complications. We also compared procedural, fluoroscopy times, and freedom from atrial tachyarrhythmias (ATs) at follow-up (secondary endpoints). Twenty and 70 studies were included for PFA and CRYO, respectively. PFA demonstrated greater acute procedural success on a vein basis (99.9% vs 99.1%; p<0.001), as well as per patient (99.5% vs 98.4%; p<0.001). PFA yielded lower overall periprocedural complications (3.1% vs 5.6%; p<0.001), shorter procedural time (75.9 min vs 105.6 min; p<0.001) and fluoroscopy time (14.2 min vs 18.9 min; p<0.001) compared to CRYO. No differences were found for major periprocedural complications (1.2% vs 1.0%; p=0.46) and freedom from ATs at 1 year (82.3% vs 80.3%; Log-rank p= 0.61). PFA contributed to higher acute procedural success, and safety compared to CRYO. No statistically significant differences in AT recurrence at 1-year follow-up were observed.