HE WANG

Mr. HE WANG

Electrical and Computer Engineering, Worcester Polytechnic Institute, Worcester, Massachusetts, USA
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 September 2023 in eClinicalMedicine
Verified
Journal Article
Open access
TLTingting Liu
Tingting Liu
SLSihan Li
Sihan Li
SDSilu Ding
Silu Ding
JQJingping Qiu
Jingping Qiu
CRChengbo Ren
Chengbo Ren
JDJun Dang
Jun Dang
Pneumonitis is a common complication for patients with locally advanced non-small cell lung cancer undergoing definitive chemoradiotherapy (CRT). It remains unclear whether there is ethnic difference in the incidence of post-CRT pneumonitis. PubMed, Embase, Cochrane Library, and Web of Science were searched for eligible studies from January 1, 2000 to April 30, 2023. The outcomes of interest were incidence rates of pneumonitis. The random-effect model was used for statistical analysis. This meta-analysis was registered with PROSPERO (CRD42023416490). A total of 248 studies involving 28,267 patients were included. Among studies of CRT without immunotherapy, the pooled rates of pneumonitis for Asian patients were significantly higher than that for non-Asian patients (all grade: 66.8%, 95% CI: 59.2%–73.9% vs. 28.1%, 95% CI: 20.4%–36.4%; P < 0.0001; grade ≥2: 25.1%, 95% CI: 22.9%–27.3% vs. 14.9%, 95% CI: 12.0%–18.0%; P < 0.0001; grade ≥3: 6.5%, 95% CI: 5.6%–7.3% vs. 4.6%, 95% CI: 3.4%–5.9%; P = 0.015; grade 5: 0.6%, 95% CI: 0.3%–0.9% vs. 0.1%, 95% CI: 0.0%–0.2%; P < 0.0001). Regarding studies of CRT plus immunotherapy, Asian patients had higher rates of all-grade (74.8%, 95% CI: 63.7%–84.5% vs. 34.3%, 95% CI: 28.7%–40.2%; P < 0.0001) and grade ≥2 (34.0%, 95% CI: 30.7%–37.3% vs. 24.6%, 95% CI: 19.9%–29.3%; P = 0.001) pneumonitis than non-Asian patients, but with no significant differences in the rates of grade ≥3 and grade 5 pneumonitis. Results from subgroup analyses were generally similar to that from the all studies. In addition, the pooled median/mean of lung volume receiving ≥20 Gy and mean lung dose were relatively low in Asian studies compared to that in non-Asian studies. Asian patients are likely to have a higher incidence of pneumonitis than non-Asian patients, which appears to be due to the poor tolerance of lung to radiation. Nevertheless, these findings are based on observational studies and with significant heterogeneity, and need to be validated in future large prospective studies focusing on the subject. None.

23 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
HWHE WANG
HE WANG
JLjianan li
jianan li
BMBenjamin Edward McDonald
Benjamin Edward McDonald
TFTodd R. Farrell
Todd R. Farrell
XHXinming Huang
Xinming Huang
ECEdward Clancy
Edward Clancy
Wireless wearable sensor systems for biomedical signal acquisition have developed rapidly in recent years. Multiple sensors are often deployed for monitoring common bioelectric signals, such as EEG (electroencephalogram), ECG (electrocardiogram), and EMG (electromyogram). Compared with ZigBee and low-power Wi-Fi, Bluetooth Low Energy (BLE) can be a more suitable wireless protocol for such systems. However, current time synchronization methods for BLE multi-channel systems, via either BLE beacon transmissions or additional hardware, cannot satisfy the requirements of high throughput with low latency, transferability between commercial devices, and low energy consumption. We developed a time synchronization and simple data alignment (SDA) algorithm, which was implemented in the BLE application layer without the need for additional hardware. We further developed a linear interpolation data alignment (LIDA) algorithm to improve upon SDA. We tested our algorithms using sinusoidal input signals at different frequencies (10 to 210 Hz in increments of 20 Hz—frequencies spanning much of the relevant range of EEG, ECG, and EMG signals) on Texas Instruments (TI) CC26XX family devices, with two peripheral nodes communicating with one central node. The analysis was performed offline. The lowest average (±standard deviation) absolute time alignment error between the two peripheral nodes achieved by the SDA algorithm was 384.3 ± 386.5 μs, while that of the LIDA algorithm was 189.9 ± 204.7 μs. For all sinusoidal frequencies tested, the performance of LIDA was always statistically better than that of SDA. These average alignment errors were quite low—well below one sample period for commonly acquired bioelectric signals.

13 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
JLjianan li
jianan li
EQEric Quintin
Eric Quintin
HWHE WANG
HE WANG
BMBenjamin Edward McDonald
Benjamin Edward McDonald
TFTodd R. Farrell
Todd R. Farrell
ECEdward Clancy
Edward Clancy
Wearable wireless biomedical sensors have emerged as a rapidly growing research field. For many biomedical signals, multiple sensors distributed about the body without local wired connections are required. However, designing multisite systems at low cost with low latency and high precision time synchronization of acquired data is an unsolved problem. Current solutions use custom wireless protocols or extra hardware for synchronization, forming custom systems with high power consumption that prohibit migration between commercial microcontrollers. We aimed to develop a better solution. We successfully developed a low-latency, Bluetooth low energy (BLE)-based data alignment method, implemented in the BLE application layer, making it transferable between manufacturer devices. The time synchronization method was tested on two commercial BLE platforms by inputting common sinusoidal input signals (over a range of frequencies) to evaluate time alignment performance between two independent peripheral nodes. Our best time synchronization and data alignment method achieved absolute time differences of 69 ± 71 μs for a Texas Instruments (TI) platform and 477 ± 490 μs for a Nordic platform. Their 95th percentile absolute errors were more comparable—under 1.8 ms for each. Our method is transferable between commercial microcontrollers and is sufficient for many biomedical applications.

30 July 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HWHE WANG
HE WANG
KRKiriaki Rajotte
Kiriaki Rajotte
HWHaopeng Wang
Haopeng Wang
CDChenyun Dai
Chenyun Dai
ZZZiling Zhu
Ziling Zhu
ECEdward Clancy
Edward Clancy
To facilitate the broader use of EMG signal whitening, we studied four whitening procedures of various complexities, as well as the roles of sampling rate and noise correction. We separately analyzed force-varying and constant-force contractions from 64 subjects who completed constant-posture tasks about the elbow over a range of forces from 0% to 50% maximum voluntary contraction (MVC). From the constant-force tasks, we found that noise correction via the root difference of squares (RDS) method consistently reduced EMG recording noise, often by a factor of 5–10. All other primary results were from the force-varying contractions. Sampling at 4096 Hz provided small and statistically significant improvements over sampling at 2048 Hz (~3%), which, in turn, provided small improvements over sampling at 1024 Hz (~4%). In comparing equivalent processing variants at a sampling rate of 4096 Hz, whitening filters calibrated to the EMG spectrum of each subject generally performed best (4.74% MVC EMG-force error), followed by one universal whitening filter for all subjects (4.83% MVC error), followed by a high-pass filter whitening method (4.89% MVC error) and then a first difference whitening filter (4.91% MVC error)—but none of these statistically differed. Each did significantly improve from EMG-force error without whitening (5.55% MVC). The first difference is an excellent whitening option over this range of contraction forces since no calibration or algorithm decisions are required.

15 November 2024 in Sensors
Verified
Journal Article
Open access
PDF file
HWHaopeng Wang
Haopeng Wang
HWHE WANG
HE WANG
CDChenyun Dai
Chenyun Dai
XHXinming Huang
Xinming Huang
ECEdward Clancy
Edward Clancy
Deep neural networks (DNNs) and transfer learning (TL) have been used to improve surface electromyogram (sEMG)-based force estimation. However, prior studies focused mostly on applying TL within one joint, which limits dataset size and diversity. Herein, we investigated cross-joint TL between two upper-limb joints with four DNN architectures using sliding windows. We used two feedforward and two recurrent DNN models with feature engineering and feature learning, respectively. We found that the dependencies between sEMG and force are short-term (<400 ms) and that sliding windows are sufficient to capture them, suggesting that more complicated recurrent structures may not be necessary. Also, using DNN architectures reduced the required sliding window length. A model pre-trained on elbow data was fine-tuned on hand–wrist data, improving force estimation accuracy and reducing the required training data amount. A convolutional neural network with a 391 ms sliding window fine-tuned using 20 s of training data had an error of 6.03 ± 0.49% maximum voluntary torque, which is statistically lower than both our multilayer perceptron model with TL and a linear regression model using 40 s of training data. The success of TL between two distinct joints could help enrich the data available for future deep learning-related studies.