Alfredo Blandino

Prof. Dr. Alfredo Blandino


Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in American Journal of Roentgenology
Verified
Journal Article
Closed access
EAErnesto Amato
Ernesto Amato
ISIgnazio Salamone
Ignazio Salamone
SNSerena Naso
Serena Naso
ABAntonio Bottari
Antonio Bottari
MGMichele Gaeta
Michele Gaeta
ABAlfredo Blandino
Alfredo Blandino
The purpose of this article is to quantify the CT radiation dose increment in five organs resulting from the administration of iodinated contrast medium.

1 December 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
TDTommaso D'Angelo
Tommaso D'Angelo
CGChrysanthos Grigoratos
Chrysanthos Grigoratos
SMSilvio Mazziotti
Silvio Mazziotti
KBKonstantinos Bratis
Konstantinos Bratis
FPFaraz Pathan
Faraz Pathan
ENEike Nagel
Eike Nagel
Reducing time and contrast agent doses are important goals to provide cost-efficient cardiovascular magnetic resonance (CMR) imaging. Limited information is available regarding the feasibility of evaluating left ventricular (LV) function after gadobutrol injection as well as defining the lowest dose for high quality scar imaging. We sought to evaluate both aspects separately and systematically to provide an optimized protocol for contrast-enhanced CMR (CE-CMR) using gadobutrol. This is a prospective, randomized, single-blind cross-over study performed in two different populations. The first population consisted of 30 patients with general indications for a rest CE-CMR who underwent cine-imaging before and immediately after intravenous administration of 0.1 mmol/kg body-weight of gadobutrol. Quantitative assessment of LV volumes and function was performed by the same reader in a randomized and blinded fashion. The second population was composed of 30 patients with indication to late gadolinium enhancement (LGE) imaging, which was performed twice at different gadobutrol doses (0.1 mmol/kg vs. 0.2 mmol/kg) and at different time delays (5 and 10 min vs. 5, 10, 15 and 20 min), within a maximal interval of 21 days. LGE images were analysed qualitatively (contrast-to-noise ratio) and quantitatively (LGE%-of-mass). Excellent correlation between pre- and post-contrast cine-imaging was found, with no difference of LV stroke volume and ejection fraction (p = 0.538 and p = 0.095, respectively). End-diastolic-volume and end-systolic-volume were measured significantly larger after contrast injection (p = 0.008 and p = 0.001, respectively), with a mean difference of 3.7 ml and 2.9 ml, respectively. LGE imaging resulted in optimal contrast-to-noise ratios 10 min post-injection for a gadobutrol dose of 0.1 mmol/kg body-weight and 20 min for a dose of 0.2 mmol/kg body-weight. At these time points LGE quantification did not significantly differ (0.1 mmol/kg: 11% (16.4); 0.2 mmol/kg: 12% (14.5); p = 0.059), showing excellent correlation (ICC = 0.957; p < 0.001). A standardized CE-CMR rest protocol giving a dose of 0.1 mmol/kg of gadobutrol before cine-imaging and performing LGE 10 min after injection represents a fast low-dose protocol without significant loss of information in comparison to a longer protocol with cine-imaging before contrast injection and a higher dose of gadobutrol. This approach allows to reduce examination time and costs as well as minimize contrast-agent exposure.

1 May 2011 in Inflammatory Bowel Diseases
Verified
Journal Article
Closed access
SMSilvio Mazziotti
Silvio Mazziotti
GAGiorgio Ascenti
Giorgio Ascenti
ESEmanuele Scribano
Emanuele Scribano
MGMichele Gaeta
Michele Gaeta
APAlessia Pandolfo
Alessia Pandolfo
ABAlfredo Blandino
Alfredo Blandino

2 July 2021 in European Radiology
Verified
Journal Article
Open access
PDF file
MCMarco Cavallaro
Marco Cavallaro
TDTommaso D'Angelo
Tommaso D'Angelo
MAMoritz H. Albrecht
Moritz H. Albrecht
IYIbrahim Yel
Ibrahim Yel
SMSimon S. Martin
Simon S. Martin
CBChristian Booz
Christian Booz
Objectives: To compare dual-energy CT (DECT) and MRI for assessing presence and extent of traumatic bone marrow edema (BME) and fracture line depiction in acute vertebral fractures. Methods: Eighty-eight consecutive patients who underwent dual-source DECT and 3-T MRI of the spine were retrospectively analyzed. Five radiologists assessed all vertebrae for presence and extent of BME and for identification of acute fracture lines on MRI and, after 12 weeks, on DECT series. Additionally, image quality, image noise, and diagnostic confidence for overall diagnosis of acute vertebral fracture were assessed. Quantitative analysis of CT numbers was performed by a sixth radiologist. Two radiologists analyzed MRI and grayscale DECT series to define the reference standard. Results: For assessing BME presence and extent, DECT showed high sensitivity (89% and 84%, respectively) and specificity (98% in both), and similarly high diagnostic confidence compared to MRI (2.30 vs. 2.32; range 0–3) for the detection of BME (p = .72). For evaluating acute fracture lines, MRI achieved high specificity (95%), moderate sensitivity (76%), and a significantly lower diagnostic confidence compared to DECT (2.42 vs. 2.62, range 0–3) (p < .001). A cutoff value of − 0.43 HU provided a sensitivity of 89% and a specificity of 90% for diagnosing BME, with an overall AUC of 0.96. Conclusions: DECT and MRI provide high diagnostic confidence and image quality for assessing acute vertebral fractures. While DECT achieved high overall diagnostic accuracy in the analysis of BME presence and extent, MRI provided moderate sensitivity and lower confidence for evaluating fracture lines. Key Points: • In the setting of spinal trauma, dual-energy CT (DECT) is highly accurate in the evaluation of acute vertebral fractures and bone marrow edema presence and extent. • MRI provides moderate sensitivity and lower diagnostic confidence for the depiction of acute fracture lines, when compared to DECT, which might result in potentially inaccurate and underestimated severity assessment of injuries in certain cases when no fracture lines are visible on MRI. • DECT may represent a valid imaging alternative to MRI in specific settings of acute spinal trauma and in follow-up examinations, especially in elderly or unstable patients and in cases of subtle or complex orientated fracture lines.

31 May 2017 in BioMed Research International
Verified
Journal Article
Open access
PDF file
SMSilvio Mazziotti
Silvio Mazziotti
GCGiuseppe Cicero
Giuseppe Cicero
TDTommaso D’aNgelo
Tommaso D’aNgelo
MMMaria Adele Marino
Maria Adele Marino
CVCarmela Visalli
Carmela Visalli
ABAlfredo Blandino
Alfredo Blandino
The increased use of imaging modalities in the last years has led to a greater incidence in depicting abdominal incidental lesions. In particular, “incidentalomas” of the kidney are discovered in asymptomatic patients or patients who suffer from diseases not directly related to the kidneys. The aim of this paper is to provide the radiologist with a useful guide to recognize and classify the main incidental renal findings with the purpose of establishing the correct management. First we describe the so-called “pseudotumors” which are important to recognize in order to avoid a misdiagnosis. Afterwards we categorize true renal lesions into cystic and solid types, reporting radiological signs helpful in differentiating between benign and malignant nature.

14 August 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
TDTommaso D'Angelo
Tommaso D'Angelo
LLLudovica Rosa Maria Lanzafame
Ludovica Rosa Maria Lanzafame
AMAntonino Micari
Antonino Micari
ABAlfredo Blandino
Alfredo Blandino
IYIbrahim Yel
Ibrahim Yel
SMSilvio Mazziotti
Silvio Mazziotti
Background: To evaluate if coronary CT angiography (CCTA) monoenergetic reconstructions, obtained with a dual-layer spectral detector computed tomography (DLCT) system, offer improved image quality compared with 120 kVp conventional images without affecting the quantitative assessment of coronary stenoses. Methods: Fifty CCTA datasets (30 men; mean age: 61.6 ± 12.3 years) acquired with a DLCT system were reconstructed using virtual monoenergetic images (VMI) from 40 to 100 keV with 10 keV increment and compared with conventional images. An analysis of objective image quality was performed, evaluating the signal- and contrast-to-noise ratio. For the subjective assessment, two readers used a 5-point Likert scoring system to evaluate sharpness, noise, demarcation of coronary plaques, vascular contrast, and an overall score. Furthermore, coronary stenoses were analyzed for each vessel to describe the diagnostic agreement between monoenergetic images and conventional images. Results: The objective image analysis showed that all reconstructions from 70 keV to 40 keV show higher SNR (from 61.33 ± 12.46 to 154.22 ± 42.91, respectively) and CNR (from 51.45 ± 11.19 to 135.63 ± 39.38, respectively) compared with conventional images (all p < 0.001). The 40 keV monoenergetic images obtained the best average score for sharpness, vascular contrast, and for the overall impression (all with p < 0.001). The detection and grading of stenoses of the coronary arteries with conventional and monoenergetic images at 70 keV and 40 keV showed an overall excellent interobserver agreement (k= 0.81 [0.72–0.91]). Conclusions: The 40 keV virtual monoenergetic images obtained with a DLCT system allow the objective and subjective image quality of coronary CT angiography to be improved.