As one of the most promising renewable energy resources, a large amount of wind energy has been implemented all around the world since 1990s. Increasing the size of the wind turbines and the harsh operating environment lead to higher failure rates on the wind turbines compared with other renewable resources. As the result, not only unplanned maintenance and repairments but also downtime of the wind turbine increases the operation cost significantly. In addition, the long-distance transmission lines are required to transfer the wind generation power to the load centers due to the remote operation location of the wind farms. To improve the power transfer capability, series compensated lines are adopted in many cases. However, subsynchronous control interactions (SSCI) could happen between series compensated transmission lines and wind turbines. This may damage wind turbine components severely and cause stability issues in the power grids. Currently, various condition monitoring systems have been developed and applied for wind turbines. Different SSCI detection mechanisms are also proposed in many studies. This paper proposes an FPGA-CPU based holistic monitoring system which not only provides both condition and SSCI monitoring functions simultaneously in real-time but also records necessary data for post-event analysis.
To reduce carbon dioxide emissions from traditional drying methods, this research investigated the use of microwave technology for drying Standard Thai Rubber (STR) in Thailand. Commercial microwave ovens were modified and integrated with the microwave emitting power control system to maintain the appropriate temperature levels to evaporate the moisture from rubber. Throughout the drying process, the temperature of the rubber was measured both internally and outside. The results revealed that STR5L and STR20 could be dried satisfactorily and met the requirements for standard Thai rubber properties by utilizing 500 W for 140 and 120 min, respectively. By keeping the temperatures less than 150 °C, rubbers’ molecular structure is not destroyed from internal heat stress. Although utilizing less power for a longer period of time is possible, more energy was used, which is unfavorable. Compared to traditional hot air drying technologies, which take approximately 4–6 h for the drying process, microwave technology potentially reduces the drying time by half or more. If solar energy is used to supply electrical energy, 300,000 tons of Carbon dioxide can potentially be eliminated annually in the STR drying industry in Thailand by promoting approximately 1115 MW of Photovoltaic technology installations with the solar resources in southern Thailand.
This study presents a simulation-driven optimization of thermochemical energy storage using SrCl2-based systems for integration with solar energy technologies. Thermochemical sorption systems offer promising potential for enhancing solar energy-storage efficiency by capturing both thermal and electrical energy. However, optimizing sorption processes remains crucial for maximizing energy storage capacity. This work utilized advanced simulation tools to analyze the heat and mass transfer dynamics within SrCl2-EG composites and evaluate system performance under varying compression ratios (CR), reactant temperatures, and heat transfer fluid (HTF) flow rates. The results demonstrate that adjusting CR enhances the overall system efficiency. CR = 4 yields the highest desorption rate of 93.8%, while reducing the required HTF mass flow by nearly tenfold compared to lower CR values. Higher CR contributes to a reduction in sensible heat loss, allowing a greater percentage of thermal energy to be captured. Simulations also show that optimized SrCl2-based systems can integrate effectively with solar energy conversion technologies, making them highly suitable for both energy storage and cooling applications. This research underscores the role of thermochemical energy storage systems in providing more sustainable and efficient solar energy solutions. By reducing energy losses and improving the reliability of the energy storage process, SrCl2-based systems offer significant advantages for renewable energy integration.
Insightful information on energy use encourages home residents to conduct home energy conservation. This paper proposes an experimental design for an energy disaggregation system based on the low-computational-cost approaches of multi-target classification and multi-target regression, which are under the multi-target learning framework. The experiments are set up to determine the optimal learning algorithm and model parameters. In addition, the designated system can provide inference of the appliance power state and the estimated power consumption from both approaches. The kernel density estimation technique is utilized to formulate the appliance power state as a finite-state machine for the multi-target classification approach. Multi-target regression can directly provide the estimation of appliance power demand from the aggregate data, and this work unifies the system’s design together with multi-target classification. The predictive performances obtained through the F-score (micro-averaged) and power estimation accuracy index for the power state inference and the estimated power demand, respectively, are shown to outperform a deep-learning-based denoising autoencoder network under the same data settings from both approaches. The results lead to a recommendation to apply the approach in home energy monitoring, which is mainly based on the characteristics of appliance power and the information that the residents wish to perceive.
This paper presents a data-driven energy management scheme for fuel cell and battery electric vehicles, formulated as a constrained optimal control problem. The proposed method employs a co-state network trained using real-time measurements to estimate the control law without requiring prior knowledge of the system model or a complete dataset across the full operating domain. In contrast to conventional reinforcement learning approaches, this method avoids the issue of high dimensionality and does not depend on extensive offline training. Robustness is demonstrated by treating uncertain and time-varying elements, including power consumption from air conditioning systems, variations in road slope, and passenger-related demands, as unknown disturbances. The desired state of charge is defined as a reference trajectory, and the control input is computed while ensuring compliance with all operational constraints. Validation results based on a combined driving profile confirm the effectiveness of the proposed controller in maintaining the battery charge, reducing fluctuations in fuel cell power output, and ensuring reliable performance under practical conditions. Comparative evaluations are conducted against two benchmark controllers: one designed to maintain a constant state of charge and another based on a soft actor–critic learning algorithm.
Photovoltaic–thermal (PVT) collectors co-generate electricity and heat—natural front ends for thermochemical energy storage (TCES)—provided the heat transfer fluid stays above the reactor’s desorption temperature. Using an eight-node model of a 0.6834 m2 collector at 8.64° N whose thermal core is partially validated against measured data from the same tropical–coastal site (rooftop PV module temperature, RMSE 3.8 °C; prototype absorber-to-water heat transfer, RMSE 1.3 °C), flow-regulated to the ≈95 °C SrCl2/NH3 desorption threshold, we quantify the energy and exergy delivered for charging under tropical–monsoon intermittency. The 95 °C setpoint operation, the ≈5.3 h charging window, and all reported exergy yields are simulated: the built prototype delivered hot water peaking at 79 °C and did not reach the 95 °C setpoint. On a measured clear-sky day (clearness index Kt = 0.52), the collector yields 1.38 kWh of energy but only 0.43 kWh of exergy (first-law efficiency ≈ 38%; gross exergy efficiency ≈ 13%); across a 30-seed synthetic-intermittency ensemble, the exergy yield is 0.678 kWh at ≈14% gross exergy efficiency (≈52% combined first-law efficiency). In both cases, the thermal stream dominates the energy output while the electrical stream dominates the exergy output—on the sunlit day, the exergy is about 80% electrical—because 95 °C heat carries a Carnot factor (exergetic quality factor, 1 − Ta/T7, at the instantaneous ambient dead state) of only ≈0.18 and an integrated Bejan/Kotas thermal-exergy quality of only ≈0.09. The controller holds the outlet within 1.4 K of the setpoint for ≈5.3 h, whereas no fixed flow in the 0.5–5.0 L min−1 range ever reaches it: feedback control is a structural enabler, not an optimisation. On overcast days, the threshold is never reached and charging heat collapses to zero, leaving a PV-only generator. Exergy delivery is nonetheless nearly controller-independent: the accumulated exergy delivery deficit after a 50% irradiance drop is 937 kJ, a controller-independent value changing only 1.3% across a systematic 4 × 4 gain sweep (Kp 0.33–2.7×, Kd 0.25–5× of nominal), and predictive control improves it by ≤1%. For PVT–TCES at this scale, the decisive lever is deployability, not control sophistication.