Choosak Rittiphet

Dr. Choosak Rittiphet


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2026 in Energies
Verified
Journal Article
Open access
PDF file
CRChoosak Rittiphet
Choosak Rittiphet
SKSuratsavadee Koonlaboon Korkua
Suratsavadee Koonlaboon Korkua
KFKrit Funsian
Krit Funsian
MTMohammad Faridun Naim Tajuddin
Mohammad Faridun Naim Tajuddin
SANTANU KUMAR DASHSANTANU KUMAR DASH
SANTANU KUMAR DASH
Kamon ThinsuratKamon Thinsurat
Kamon Thinsurat
Photovoltaic–thermal (PVT) collectors co-generate electricity and heat—natural front ends for thermochemical energy storage (TCES)—provided the heat transfer fluid stays above the reactor’s desorption temperature. Using an eight-node model of a 0.6834 m2 collector at 8.64° N whose thermal core is partially validated against measured data from the same tropical–coastal site (rooftop PV module temperature, RMSE 3.8 °C; prototype absorber-to-water heat transfer, RMSE 1.3 °C), flow-regulated to the ≈95 °C SrCl2/NH3 desorption threshold, we quantify the energy and exergy delivered for charging under tropical–monsoon intermittency. The 95 °C setpoint operation, the ≈5.3 h charging window, and all reported exergy yields are simulated: the built prototype delivered hot water peaking at 79 °C and did not reach the 95 °C setpoint. On a measured clear-sky day (clearness index Kt = 0.52), the collector yields 1.38 kWh of energy but only 0.43 kWh of exergy (first-law efficiency ≈ 38%; gross exergy efficiency ≈ 13%); across a 30-seed synthetic-intermittency ensemble, the exergy yield is 0.678 kWh at ≈14% gross exergy efficiency (≈52% combined first-law efficiency). In both cases, the thermal stream dominates the energy output while the electrical stream dominates the exergy output—on the sunlit day, the exergy is about 80% electrical—because 95 °C heat carries a Carnot factor (exergetic quality factor, 1 − Ta/T7, at the instantaneous ambient dead state) of only ≈0.18 and an integrated Bejan/Kotas thermal-exergy quality of only ≈0.09. The controller holds the outlet within 1.4 K of the setpoint for ≈5.3 h, whereas no fixed flow in the 0.5–5.0 L min−1 range ever reaches it: feedback control is a structural enabler, not an optimisation. On overcast days, the threshold is never reached and charging heat collapses to zero, leaving a PV-only generator. Exergy delivery is nonetheless nearly controller-independent: the accumulated exergy delivery deficit after a 50% irradiance drop is 937 kJ, a controller-independent value changing only 1.3% across a systematic 4 × 4 gain sweep (Kp 0.33–2.7×, Kd 0.25–5× of nominal), and predictive control improves it by ≤1%. For PVT–TCES at this scale, the decisive lever is deployability, not control sophistication.

22 August 2026 in Energies
Verified
Journal Article
Open access
PDF file
SKSuratsavadee Koonlaboon Korkua
Suratsavadee Koonlaboon Korkua
KFKrit Funsian
Krit Funsian
CRChoosak Rittiphet
Choosak Rittiphet
MTMohammad Faridun Naim Tajuddin
Mohammad Faridun Naim Tajuddin
SANTANU KUMAR DASHSANTANU KUMAR DASH
SANTANU KUMAR DASH
Kamon ThinsuratKamon Thinsurat
Kamon Thinsurat
Photovoltaic–thermal (PVT) collectors coupled to thermochemical energy storage (TCES) can turn intermittent low-grade solar heat into a dispatchable service, but solar intermittency poses a closed-loop control problem. A companion study established the feedback-only lower bound: a 937 kJ accumulated exergy-delivery-deficit benchmark under optimally tuned proportional–integral–derivative (PID) flow control. The corresponding upper bound is quantified here by means of a deliberately idealised search-based predictive controller that, at each 10 s step, enumerates 51 candidate pump rates, predicts the reactor-inlet temperature by a single forward-Euler step, and is granted perfect future irradiance. On the experimentally validated shared plant (matched to the companion baseline), against an optimally tuned PID, the perfect-foresight advantage is marginal: +0.96% daily exergy on synthetic days and +0.07–0.24% on two measured Walailak University monsoon days, all controllers tracking within 6–13 K on the measured days. Under tropical-monsoon irradiance, the 95 °C desorption setpoint is rarely sustained, so the delivered exergy is nearly controller-independent: the perfect-foresight upper bound lies just above the feedback-only lower bound, and together the two results bracket the exergy envelope available to any flow-rate controller of this system. A horizon sweep localises the bottleneck to internal-model fidelity, not anticipation depth. The eight-node plant is validated against measured module temperature (root-mean-square error 3.5 °C, coefficient of determination R2 = 0.89) and a copper-tube PVT prototype (1.5 °C; peak hot water up to 79 °C). The central contribution is therefore a rigorously defined, experimentally grounded upper bound showing that, at this scale and latitude, deployability rather than anticipation is the effective design lever.

Verified
Journal Article
Open access
PDF file
PSPrachid Saramolee
Prachid Saramolee
SSSiraporn Sakphrom
Siraporn Sakphrom
CRChoosak Rittiphet
Choosak Rittiphet
SKSupawat Kotchapradit
Supawat Kotchapradit
KOKoki Ogura
Koki Ogura
SCSarawuth Chaimool
Sarawuth Chaimool
Encapsulation for wireless dairy-cattle implants must resist acidic, moisture-rich gastrointestinal conditions while remaining transparent to radio-frequency (RF) signals. This study evaluated vulcanized natural rubber (NR) latex as an intraruminal encapsulant, examining how total solid content (TSC; 30, 40, 50 wt%), stirring duration (24–72 h), and TiO2 loading affect tensile and tear strength, acidic swelling, dip-coating thickness, and received signal strength indicator (RSSI) at 433 MHz. Multilayer dip-coating produced films 0.25–0.38 mm thick. Tensile strength rose with TSC and stirring (26.6 → 32.2 MPa), whereas tear strength peaked at 40 wt% (31.97 N mm−1). Adding 5 phr (parts per hundred rubber) TiO2 cut pH-4 swelling ~four-fold (21.1 → 5.25%) with a negligible RSSI penalty, and 3–5 coating layers kept the link well above the −120 dBm sensitivity floor over 5–55 m. The optimum—40 wt% TSC, 72 h stirring, 5 phr TiO2—best balanced mechanical integrity, swelling resistance, thickness, and wireless performance. Vulcanized NR is therefore a promising bio-based encapsulant under simulated conditions; dielectric characterization, long-term aging, and in vivo validation remain future work.