Photovoltaic–thermal (PVT) collectors co-generate electricity and heat—natural front ends for thermochemical energy storage (TCES)—provided the heat transfer fluid stays above the reactor’s desorption temperature. Using an eight-node model of a 0.6834 m2 collector at 8.64° N whose thermal core is partially validated against measured data from the same tropical–coastal site (rooftop PV module temperature, RMSE 3.8 °C; prototype absorber-to-water heat transfer, RMSE 1.3 °C), flow-regulated to the ≈95 °C SrCl2/NH3 desorption threshold, we quantify the energy and exergy delivered for charging under tropical–monsoon intermittency. The 95 °C setpoint operation, the ≈5.3 h charging window, and all reported exergy yields are simulated: the built prototype delivered hot water peaking at 79 °C and did not reach the 95 °C setpoint. On a measured clear-sky day (clearness index Kt = 0.52), the collector yields 1.38 kWh of energy but only 0.43 kWh of exergy (first-law efficiency ≈ 38%; gross exergy efficiency ≈ 13%); across a 30-seed synthetic-intermittency ensemble, the exergy yield is 0.678 kWh at ≈14% gross exergy efficiency (≈52% combined first-law efficiency). In both cases, the thermal stream dominates the energy output while the electrical stream dominates the exergy output—on the sunlit day, the exergy is about 80% electrical—because 95 °C heat carries a Carnot factor (exergetic quality factor, 1 − Ta/T7, at the instantaneous ambient dead state) of only ≈0.18 and an integrated Bejan/Kotas thermal-exergy quality of only ≈0.09. The controller holds the outlet within 1.4 K of the setpoint for ≈5.3 h, whereas no fixed flow in the 0.5–5.0 L min−1 range ever reaches it: feedback control is a structural enabler, not an optimisation. On overcast days, the threshold is never reached and charging heat collapses to zero, leaving a PV-only generator. Exergy delivery is nonetheless nearly controller-independent: the accumulated exergy delivery deficit after a 50% irradiance drop is 937 kJ, a controller-independent value changing only 1.3% across a systematic 4 × 4 gain sweep (Kp 0.33–2.7×, Kd 0.25–5× of nominal), and predictive control improves it by ≤1%. For PVT–TCES at this scale, the decisive lever is deployability, not control sophistication.
Photovoltaic–thermal (PVT) collectors coupled to thermochemical energy storage (TCES) can turn intermittent low-grade solar heat into a dispatchable service, but solar intermittency poses a closed-loop control problem. A companion study established the feedback-only lower bound: a 937 kJ accumulated exergy-delivery-deficit benchmark under optimally tuned proportional–integral–derivative (PID) flow control. The corresponding upper bound is quantified here by means of a deliberately idealised search-based predictive controller that, at each 10 s step, enumerates 51 candidate pump rates, predicts the reactor-inlet temperature by a single forward-Euler step, and is granted perfect future irradiance. On the experimentally validated shared plant (matched to the companion baseline), against an optimally tuned PID, the perfect-foresight advantage is marginal: +0.96% daily exergy on synthetic days and +0.07–0.24% on two measured Walailak University monsoon days, all controllers tracking within 6–13 K on the measured days. Under tropical-monsoon irradiance, the 95 °C desorption setpoint is rarely sustained, so the delivered exergy is nearly controller-independent: the perfect-foresight upper bound lies just above the feedback-only lower bound, and together the two results bracket the exergy envelope available to any flow-rate controller of this system. A horizon sweep localises the bottleneck to internal-model fidelity, not anticipation depth. The eight-node plant is validated against measured module temperature (root-mean-square error 3.5 °C, coefficient of determination R2 = 0.89) and a copper-tube PVT prototype (1.5 °C; peak hot water up to 79 °C). The central contribution is therefore a rigorously defined, experimentally grounded upper bound showing that, at this scale and latitude, deployability rather than anticipation is the effective design lever.
Encapsulation for wireless dairy-cattle implants must resist acidic, moisture-rich gastrointestinal conditions while remaining transparent to radio-frequency (RF) signals. This study evaluated vulcanized natural rubber (NR) latex as an intraruminal encapsulant, examining how total solid content (TSC; 30, 40, 50 wt%), stirring duration (24–72 h), and TiO2 loading affect tensile and tear strength, acidic swelling, dip-coating thickness, and received signal strength indicator (RSSI) at 433 MHz. Multilayer dip-coating produced films 0.25–0.38 mm thick. Tensile strength rose with TSC and stirring (26.6 → 32.2 MPa), whereas tear strength peaked at 40 wt% (31.97 N mm−1). Adding 5 phr (parts per hundred rubber) TiO2 cut pH-4 swelling ~four-fold (21.1 → 5.25%) with a negligible RSSI penalty, and 3–5 coating layers kept the link well above the −120 dBm sensitivity floor over 5–55 m. The optimum—40 wt% TSC, 72 h stirring, 5 phr TiO2—best balanced mechanical integrity, swelling resistance, thickness, and wireless performance. Vulcanized NR is therefore a promising bio-based encapsulant under simulated conditions; dielectric characterization, long-term aging, and in vivo validation remain future work.