Asma Mushtaq

Ms. Asma Mushtaq


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
ADAli Douaki
Ali Douaki
Biresaw Demelash AberaBiresaw Demelash Abera
Biresaw Demelash Abera
GCGiuseppe Cantarella
Giuseppe Cantarella
BSBajramshahe Shkodra
Bajramshahe Shkodra
AMAsma Mushtaq
Asma Mushtaq
PLPaolo Lugli
Paolo Lugli
Furaneol is a widely used flavoring agent, which can be naturally found in different products, such as strawberries or thermally processed foods. This is why it is extremely important to detect furaneol in the food industry using ultra-sensitive, stable, and selective sensors. In this context, electrochemical biosensors are particularly attractive as they provide a cheap and reliable alternative measurement device. Carbon nanotubes (CNTs) and silver nanoparticles (AgNPs) have been extensively investigated as suitable materials to effectively increase the sensitivity of the biosensors. However, a comparison of the performance of biosensors employing CNTs and AgNPs is still missing. Herein, the effect of CNTs and AgNPs on the biosensor performance has been thoughtfully analyzed. Therefore, disposable flexible and screen printed electrochemical aptasensor modified with CNTs (CNT-ME), or AgNPs (AgNP-ME) have been developed. Under optimized conditions, CNT-MEs showed better performance compared to AgNP-ME, yielding a linear range of detection over a dynamic concentration range of 1 fM–35 μM and 2 pM–200 nM, respectively, as well as high selectivity towards furaneol. Finally, our aptasensor was tested in a real sample (strawberry) and validated with high-performance liquid chromatography (HPLC), showing that it could find an application in the food industry.

9 February 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
AOAntonio Orlando
Antonio Orlando
AMAsma Mushtaq
Asma Mushtaq
AGAndrea Gaiardo
Andrea Gaiardo
MVMatteo Valt
Matteo Valt
LVLia Vanzetti
Lia Vanzetti
LPLuisa Petti
Luisa Petti
Solid-state chemiresistive gas sensors have attracted a lot of researchers’ attention during the last half-century thanks to their ability to detect different gases with high sensitivity, low power consumption, low cost, and high portability. Among the most promising sensitive materials, carbon nanotubes (CNTs) have attracted a lot of interest due to their large active surface area (in the range of 50–1400 m2/g, depending on their composition) and the fact that they can operate at room temperature. In this study, single-walled carbon nanotube (SWCNT)-based sensing films were prepared and deposited by spray deposition for the fabrication of gas sensors. For the deposition, various SWCNTs were prepared in deionized water with the addition of specific surfactants, i.e., carboxymethyl cellulose (CMC) and sodium dodecyl sulfate (SDS), which act as dispersing agents to create a suitable ink for deposition. This study aims to elucidate the possible differences in the sensing performance of the fabricated devices due to the use of the two different surfactants. To achieve this goal, all the devices were tested versus ethanol (C2H5OH), carbon monoxide (CO), nitrogen dioxide (NO2), and ammonia (NH3). The produced devices demonstrated high selectivity towards NH3 and NO2. The different sensors, prepared with different deposition thicknesses (from 0.51 nm to 18.41 nm), were tested in dry and wet conditions (40% humidity), highlighting an enhanced response as a function of relative humidity. In addition, sensor performance was evaluated at different working temperatures, showing the best performance when heated up to 150 °C. The best sensing conditions we found were against NO2, sensors with 10 layers of deposition and an operating temperature of 150 °C; in this condition, sensors showed high responses compared those found in the literature (62.5%—SDS-based and 78.6%—CMC-based). Finally, cross-sensitivity measurements showed how the produced sensors are good candidates for the practical and selective detection of NO2, even in the presence of the most important interfering gases identified, i.e., NH3.