This work aims at a broad overview of the results obtained with metal-sulfide materials in the field of chemoresistive gas sensing. Indeed, despite the well-known electrical, optical, structural and morphological features previously described in the literature, metal sulfides present lack of investigation for gas sensing applications, a field in which the metal oxides still maintain a leading role owing to their high sensitivity, low cost, small dimensions and simple integration, in spite of the wide assortment of sensing materials. However, despite their great advantages, metal oxides have shown significant drawbacks, which have led to the search for new materials for gas sensing devices. In this work, Cadmium Sulfide and Tin (IV) Sulfide were investigated as functional materials for thick-film chemoresistive gas-sensors fabrication and they were tested both in thermo- and in photo-activation modes. Furthermore, electrical characterization was carried out in order to verify their gas sensing properties and material stability, by comparing the results obtained with metal sulfides to those obtained by using their metal-oxides counterparts. The results highlighted the possibility to use metal sulfides as a novel class of sensing materials, owing to their selectivity to specific compounds, stability, and the possibility to operate at room temperature.
Tin dioxide (SnO2) is the most-used semiconductor for gas sensing applications. However, lack of selectivity and humidity influence limit its potential usage. Antimony (Sb) doped SnO2 showed unique electrical and chemical properties, since the introduction of Sb ions leads to the creation of a new shallow band level and of oxygen vacancies acting as donors in SnO2. Although low-doped SnO2:Sb demonstrated an improvement of the sensing performance compared to pure SnO2, there is a lack of investigation on this material. To fill this gap, we focused this work on the study of gas sensing properties of highly doped SnO2:Sb. Morphology, crystal structure and elemental composition were characterized, highlighting that Sb doping hinders SnO2 grain growth and decreases crystallinity slightly, while lattice parameters expand after the introduction of Sb ions into the SnO2 crystal. XRF and EDS confirmed the high purity of the SnO2:Sb powders, and XPS highlighted a higher Sb concentration compared to XRF and EDS results, due to a partial Sb segregation on superficial layers of Sb/SnO2. Then, the samples were exposed to different gases, highlighting a high selectivity to NO2 with a good sensitivity and a limited influence of humidity. Lastly, an interpretation of the sensing mechanism vs. NO2 was proposed.
Among the various chemoresistive gas sensing properties studied so far, the sensing response reproducibility, i.e., the capability to reproduce a device with the same sensing performance, has been poorly investigated. However, the reproducibility of the gas sensing performance is of fundamental importance for the employment of these devices in on-field applications, and to demonstrate the reliability of the process development. This sensor property became crucial for the preparation of medical diagnostic tools, in which the use of specific chemoresistive gas sensors along with a dedicated algorithm can be used for screening diseases. In this work, the reproducibility of SmFeO3 perovskite-based gas sensors has been investigated. A set of four SmFeO3 devices, obtained from the same screen-printing deposition, have been tested in laboratory with both controlled concentrations of CO and biological fecal samples. The fecal samples tested were employed in the clinical validation protocol of a prototype for non-invasive colorectal cancer prescreening. Sensors showed a high reproducibility degree, with an error lower than 2% of the response value for the test with CO and lower than 6% for fecal samples. Finally, the reproducibility of the SmFeO3 sensor response and recovery times for fecal samples was also evaluated.
Postoperative pancreatic fistula (POPF), the major driver of morbidity and mortality following pancreatectomy, is caused by an abnormal communication between the pancreatic ductal epithelium and another epithelial surface containing pancreas-derived, enzyme-rich fluid. There is a strong correlation between the amylase content in surgically-placed drains early in the postoperative course and the development of POPF. A simple and cheap method to determine the amylase content from the drain effluent has been eagerly advocated. Here, we developed an amylase optical biosensor, based on a surface plasmon resonance (SPR) plastic optical fiber (POF), metallized with a 60 nm layer of gold and interrogated with white light. The sensor was made specific by coupling it with an anti-amylase antibody. Each surface derivatization step was optimized and studied by XPS, contact angle, and fluorescence. The POF-biosensor was tested for its response to amylase in diluted drain effluents. The volume of sample required was 50 µL and the measurement time was 8 min. The POF-biosensor showed selectivity for amylase, a calibration curve log-linear in the range of 0.8–25.8 U/L and a limit of detection (LOD) of ~0.5 U/L. In preliminary tests, the POF-biosensor allowed for the measurement of the amylase content of diluted surgically-placed drain effluents with an accuracy of >92% with respect to the gold standard. The POF-biosensor allows for reliable measurement and could be implemented to allow for a rapid bedside assessment of amylase value in drains following pancreatectomy.
Cytokines play a vital role in immune system signaling, making their detection crucial for continuous health monitoring. Among the various cytokines, tumor necrosis factor-alpha (TNF-α) stands out as a key regulator of the immune response. Notably, TNF-α can be detected in sweat at concentrations as low as pg/mL, with levels strongly correlated with those in blood. Despite its importance, sensitive, wearable, and continuous monitoring of TNF-α in sweat remains limited. To address this gap, this study presents a flexible electrochemical sensor integrated into a microfluidic system for the sensitive and selective detection of TNF-α under continuous sweat flow. First, we present the fabrication of two distinct, miniaturized designs of flexible screen-printed carbon three-electrode platforms, which are subsequently biofunctionalized with gold nanoparticles (AuNPs) coated with TNF-α-specific thiolated aptamers. Next, we compare the two geometrically distinct AuNP-aptamer-functionalized sensors, utilizing experimental and novel simulation-based characterization techniques. Finally, the sensors are integrated into a custom-built microfluidic system enabling the detection of TNF-α ranging from 0.2 to 1000 pg/mL under constant artificial sweat flow conditions, exhibiting high selectivity with negligible responses to non-specific analytes. These findings highlight the feasibility of integrating wearable cytokine sensors for detecting TNF-α under continuous sweat flow conditions, achieving clinically relevant sensitivity within the pg/mL range.