Implantable brain–computer interface (BCI) devices are an effective tool to decipher fundamental brain mechanisms and treat neural diseases. However, traditional neural implants with rigid or bulky cross-sections cause trauma and decrease the quality of the neuronal signal. Here, we propose a MEMS-fabricated flexible interface device for BCI applications. The microdevice with a thin film substrate can be readily reduced to submicron scale for low-invasive implantation. An elaborate silicon shuttle with an improved structure is designed to reliably implant the flexible device into brain tissue. The flexible substrate is temporarily bonded to the silicon shuttle by polyethylene glycol. On the flexible substrate, eight electrodes with different diameters are distributed evenly for local field potential and neural spike recording, both of which are modified by Pt-black to enhance the charge storage capacity and reduce the impedance. The mechanical and electrochemical characteristics of this interface were investigated in vitro. In vivo, the small cross-section of the device promises reduced trauma, and the neuronal signals can still be recorded one month after implantation, demonstrating the promise of this kind of flexible BCI device as a low-invasive tool for brain–computer communication.
In this study, the temperature behavior of a silicon ring resonator is experimentally investigated for cryogenics. The ring resonator shows a linear sensitivity of 63.9 pm/K in the temperature range from 180 to 300 K. And the experimental results agree well with the simulated data. The response time of the sensor is investigated by thermal analysis and a fast response of 325 ms is experimentally achieved. In addition, the developed sensor shows high performance in repeatability and stability. Based on our work, for the first time, silicon-based ring resonators are applied to cryogenic temperature sensing with the prominent advantages of compactness, chip-scale integration and complementary metal oxide-semiconductor (CMOS) compatibility. This work proves that silicon ring resonators are a potential platform for cryogenic monitoring.
To explore the versatility of speakers, a piezoelectric micro-electro-mechanical system (MEMS) speaker combining the function of a silent alarm is proposed, which mainly comprises a lead zirconate titanate (PZT) actuation layer and a rigid–flexible coupling supporting layer. Measurements performed on encapsulated prototypes mounted to an artificial ear simulator have revealed that, compared to a speaker with a rigid supporting layer, the sound pressure level (SPL) of the proposed piezoelectric MEMS speaker with a rigid–flexible coupling supporting layer is significantly higher and is especially higher by 4.1–20.1 dB in the frequency range from 20 Hz to 4.2 kHz, indicating that the rigid–flexible coupling supporting layer can improve the SPL significantly in low frequency. Moreover, the spectral distribution characteristic of its playback audio is similar to that of the commercial electromagnetic type. The device can also function as a silent alarm based on oral airflows in dangerous situations, as it performs well at recognizing words according to their unique voltage-signal characteristics, and can avoid the effects of external sound noise, body movement, long distance, and occlusion. This strategy provides inspiration for functional diversification of piezoelectric MEMS speakers.
27 August 2022 in Journal of Materials Science: Materials in Electronics
Pulsed field ablation is an emerging technique for the treatment of atrial fibrillation, and it can specifically damage cardiomyocytes without destroying surrounding tissues. However, current single-function ablation electrodes apply electric pulses at thousands of volts, which is potentially harmful to the heart. In this letter, we propose a multifunctional microelectrode for low-voltage pulsed field ablation and effect evaluation. By using finite element analysis and tests on potato tissues and in vivo experiments, we show that the soft microelectrode in multiplexed array format supports two orders of magnitude reduction in ablation voltage compared with the state of the art. Meanwhile, the electrode-tissue equivalent circuit before and after irreversible electroporation is established, and we find that the ablation effect could be evaluated by impedance. In the future, the microelectrode integrated with a medical balloon can be applied to minimally invasive surgery for improving the success rate of pulsed field ablation.