Vicarious calibration and validation techniques are important tools to ensure the long-term stability and inter-sensor consistency of satellite sensors making observations in the solar-reflective spectral domain. Automated test sites, which have continuous in situ monitoring of both ground reflectance and atmospheric conditions, can greatly increase the match-up possibilities for a wide range of space agency and commercial sensors. The Baotou calibration and validation test site in China provides operational high-accuracy and high-stability vicarious calibration and validation for high spatial resolution solar-reflective remote-sensing sensors. Two sites, given the abbreviations BTCN (an artificial site) and BSCN (a natural sandy site), have been selected as reference sites for the Committee on Earth Observation Satellites radiometric calibration network (RadCalNet). RadCalNet requires sites to provide data in a consistent format but does not specify the required operational conditions for a RadCalNet site. The two Baotou sites are the only sites to date that make spectral measurements for their continuous operation. One of the core principles of RadCalNet is that each site should have a metrologically rigorous uncertainty budget which also describes the site’s traceability to the international system of units, the SI. This paper shows a formalized metrological approach to determining and documenting the uncertainty budget and traceability of a RadCalNet site. This approach follows the Guide to the Expression of Uncertainty in Measurement. The paper describes the uncertainty analysis for bottom-of-atmosphere and top-of-atmosphere reflectance in the spectral region from 400 to 1000 nm for the Baotou sites and gives preliminary results for the uncertainty propagating this to top-of-atmosphere reflectance.
Accurately simulating the asymmetric spectral profiles of blue LEDs is crucial for photobiological research, yet it remains a challenge for traditional symmetric models. This study proposes a novel spectral simulation model that effectively captures these asymmetries. The proposed model structure is partly motivated by known broadening and dispersion mechanisms observed in real LED spectra; it employs a ‘base model + correction’ framework, where an Exponentially Modified Gaussian (EMG) function captures the primary spectral shape and falling edge and an Asymmetric Pseudo-Voigt (APV) function corrects the deviations on the rising edge. Requiring only the central wavelength and bandwidth as user inputs, the simulation results exhibit a high degree of agreement with the experimental data spectra. The model provides a rapid and robust tool for pre-evaluating light sources against regulatory criteria (e.g., >99% of the spectral intensity is in the 400–500 nm band), thereby enhancing the efficiency of experimental design in blue light protection studies.
1 February 2018 in Journal of Physics: Conference Series
Ambient temperature is the main challenge for improving the accuracy of spectral radiometry measurement in the field. In this paper, we present the considerable effect of temperature on the performance of a commercial CCD array spectrometer. Moreover, a temperature correction method for the CCD array spectrometer was developed, which calculated the spectrometer response at each pixel. The temperature correction method is very effective in correcting the spectral response. The deviation between measured and calculated spectrometer responses at the same temperature is less than 1% over the temperature range from 5°C to 40 °C.