Zhifeng Wu

Dr. Zhifeng Wu


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2011 in Physical Chemistry Chemical Physics
Verified
Journal Article
Closed access
PDF file
CWChengyin Wu
Chengyin Wu
YYYudong Yang
Yudong Yang
ZWZhifeng Wu
Zhifeng Wu
BCBozhen Chen
Bozhen Chen
HDHua Dong
Hua Dong
QGQihuang Gong
Qihuang Gong
We systematically study Coulomb explosion of nitrogen and oxygen molecules in intense 8 and 24 fs laser pulses.

27 July 2020 in Remote Sensing
Verified
Journal Article
Open access
PDF file
CGCaixia Gao
Caixia Gao
YLYaokai Liu
Yaokai Liu
JLJinru Liu
Jinru Liu
LMLingling Ma
Lingling Ma
ZWZhifeng Wu
Zhifeng Wu
NWNing Wang
Ning Wang
Field calibration is a feasible way to evaluate space-borne optical sensor observations via natural or artificial sites on Earth’s surface with the aid of synchronous surface and atmospheric characteristic data. Since field calibration is affected by the coupled effects of surface and atmospheric characteristics, the single calibration results acquired under different surface and atmospheric conditions have different biases and different uncertainties, making it difficult to determine the consistency of these multiple calibration results. In view of this, by assuming that the radiometric performance is invariant during field calibration and the calibration samples are independent of each other, the surface–atmosphere invariant Key Comparison Reference Value (KCRV) is essentially derived from various calibration results. As the number of calibration samples increases, the uncertainty in the KCRV should decrease, and the KCRV should approach the “true” value. This paper addresses a novel method for estimating a weighted average value from multiple calibration results that can be used to compare each calibration result, and this value is accepted as the KCRV. Furthermore, this method is preliminarily applied to the field calibration of the Multispectral Instrument (MSI) onboard the Sentinel-2B satellite via the desert target at the Baotou site, China. After employing a chi-squared test to verify that 12 calibration samples are independent from each other, the KCRV of the 12 calibration samples at the Baotou site is derived, which exhibits much lower uncertainty than a single sample. The results show that the KCRVs of the relative differences between the simulated and observed at-sensor reflectance are 3.75%, 5.11%, 6.09%, and 5.03% for the four bands of Sentinel-2B/MSI, respectively, and the corresponding uncertainties are 1.84%, 1.87%, 1.90%, and 1.93%. It is noted that the KCRV uncertainty obtained with only 12 calibration samples is reduced significantly, and in the future, more samples in other instrumented sites will be used to validate this method thoroughly.

5 April 2024 in Optics Express
Verified
Journal Article
Closed access
ZWZhifeng Wu
Zhifeng Wu
QWQiming Wang
Qiming Wang
CDCaihong Dai
Caihong Dai
LLLing Li
Ling Li
RSRuoduan Sun
Ruoduan Sun
QGQing Guo
Qing Guo
The spectral radiance measurement at daytime level can be realized with high accuracy, while it’s difficult when the spectral radiance is at nighttime level. We design a spectral radiance calibration facility which has the characteristics of completely unchanged spectrum over 3 orders of magnitude and approximately unchanged spectrum for about 6 orders of magnitude. It combines a spectral radiance light source, a precision aperture and a white diffuser together, make it easy to reproduce the spectral radiance at 380 nm from 4 × 10−9 W/(m2·sr·nm) to 4 × 10−3 W/(m2·sr·nm). The facility can be easily used to calibrate a spectroradiometer at nighttime level. When the spectral radiance from 380 nm to 780 nm is around 1 × 10−7W/(m2·sr·nm), the calibration uncertainty of the spectroradiometer is 0.87%∼1.0% (k = 1).

4 August 2025 in Photonics
Verified
Journal Article
Open access
PDF file
宏庄宏儒 庄
宏儒 庄
YWYanfei Wang
Yanfei Wang
CDCaihong Dai
Caihong Dai
LLLing Li
Ling Li
ZWZhifeng Wu
Zhifeng Wu
JPJiang Pan
Jiang Pan
Accurately simulating the asymmetric spectral profiles of blue LEDs is crucial for photobiological research, yet it remains a challenge for traditional symmetric models. This study proposes a novel spectral simulation model that effectively captures these asymmetries. The proposed model structure is partly motivated by known broadening and dispersion mechanisms observed in real LED spectra; it employs a ‘base model + correction’ framework, where an Exponentially Modified Gaussian (EMG) function captures the primary spectral shape and falling edge and an Asymmetric Pseudo-Voigt (APV) function corrects the deviations on the rising edge. Requiring only the central wavelength and bandwidth as user inputs, the simulation results exhibit a high degree of agreement with the experimental data spectra. The model provides a rapid and robust tool for pre-evaluating light sources against regulatory criteria (e.g., >99% of the spectral intensity is in the 400–500 nm band), thereby enhancing the efficiency of experimental design in blue light protection studies.

1 February 2018 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
ZWZhifeng Wu
Zhifeng Wu
CDCaihong Dai
Caihong Dai
YWYanfei Wang
Yanfei Wang
LLLing Li
Ling Li
For most of the array spectroradiometer, stray light is significant in UV band. Stray light correction of a UV array spectroradiometer is investigated using optical filters. If a group of filters with continuous bandpass are chosen, stray light contribution due to all the bands can be obtained using a numerical algorithm. The array spectroradiometer with the stray light corrected is used to measure the spectral irradiance of several UV lamps. The measurement results are compared to a double monochromator spectroradiometer. When xenon lamp is the array spectroradiometer calibration lamp, after stray light correction, the difference can be improved from nearly 10% to 2.0% in UVC band. When tungsten lamp is the calibration lamp, the difference can be improved from around 90% to less than 20%.

1 January 2023 in Journal of Applied Optics
Verified
Journal Article
Closed access
PDF file
HSHe Sijie
He Sijie
DCDai Caihong
Dai Caihong
CQCheng Qiutong
Cheng Qiutong
ZWZhifeng Wu
Zhifeng Wu
LLLi Ling
Li Ling
中国中国计量科学研究院光学与激光计量科学研究所,北京100013
中国计量科学研究院光学与激光计量科学研究所,北京100013
In order to reduce the inconsistency of spectral radiance caused by the aiming area differences between different spectroradiometers, the influence of field of view (FOV) angle and positioning on measurement accuracy was discussed. By establishing the spectral radiance measurement model of sunlight whiteboard and tungsten halogen lamp whiteboard, the differences between the average radiance and central radiance in the field of view of different geometric optical paths were analyzed. Numerical simulation shows that the correction factor of sunlight whiteboard path is only related to the size of FOV angle, while that of tungsten halogen lamp whiteboard path decreases with the increases of the measurement distance. When the distance is 600 mm, the correction factor of 8° and 14° FOV angle changes to 0.993 5 and 0.980 2, respectively. Finally, the experiment verified the influence of the angle error and displacement error on spectral radiance when using the tungsten halogen lamp whiteboard system. The results show that the correction factor presents asymmetry to the horizontal angle error and displacement error, and the difference between the two sides is as high as 2%. Therefore, the measurement results can be corrected according to the FOV angle and geometric positioning, which helps to improve the uncertainty level of spectral radiance measurement.