Field calibration is a feasible way to evaluate space-borne optical sensor observations via natural or artificial sites on Earth’s surface with the aid of synchronous surface and atmospheric characteristic data. Since field calibration is affected by the coupled effects of surface and atmospheric characteristics, the single calibration results acquired under different surface and atmospheric conditions have different biases and different uncertainties, making it difficult to determine the consistency of these multiple calibration results. In view of this, by assuming that the radiometric performance is invariant during field calibration and the calibration samples are independent of each other, the surface–atmosphere invariant Key Comparison Reference Value (KCRV) is essentially derived from various calibration results. As the number of calibration samples increases, the uncertainty in the KCRV should decrease, and the KCRV should approach the “true” value. This paper addresses a novel method for estimating a weighted average value from multiple calibration results that can be used to compare each calibration result, and this value is accepted as the KCRV. Furthermore, this method is preliminarily applied to the field calibration of the Multispectral Instrument (MSI) onboard the Sentinel-2B satellite via the desert target at the Baotou site, China. After employing a chi-squared test to verify that 12 calibration samples are independent from each other, the KCRV of the 12 calibration samples at the Baotou site is derived, which exhibits much lower uncertainty than a single sample. The results show that the KCRVs of the relative differences between the simulated and observed at-sensor reflectance are 3.75%, 5.11%, 6.09%, and 5.03% for the four bands of Sentinel-2B/MSI, respectively, and the corresponding uncertainties are 1.84%, 1.87%, 1.90%, and 1.93%. It is noted that the KCRV uncertainty obtained with only 12 calibration samples is reduced significantly, and in the future, more samples in other instrumented sites will be used to validate this method thoroughly.
The spectral radiance measurement at daytime level can be realized with high accuracy, while it’s difficult when the spectral radiance is at nighttime level. We design a spectral radiance calibration facility which has the characteristics of completely unchanged spectrum over 3 orders of magnitude and approximately unchanged spectrum for about 6 orders of magnitude. It combines a spectral radiance light source, a precision aperture and a white diffuser together, make it easy to reproduce the spectral radiance at 380 nm from 4 × 10−9 W/(m2·sr·nm) to 4 × 10−3 W/(m2·sr·nm). The facility can be easily used to calibrate a spectroradiometer at nighttime level. When the spectral radiance from 380 nm to 780 nm is around 1 × 10−7W/(m2·sr·nm), the calibration uncertainty of the spectroradiometer is 0.87%∼1.0% (k = 1).
Accurately simulating the asymmetric spectral profiles of blue LEDs is crucial for photobiological research, yet it remains a challenge for traditional symmetric models. This study proposes a novel spectral simulation model that effectively captures these asymmetries. The proposed model structure is partly motivated by known broadening and dispersion mechanisms observed in real LED spectra; it employs a ‘base model + correction’ framework, where an Exponentially Modified Gaussian (EMG) function captures the primary spectral shape and falling edge and an Asymmetric Pseudo-Voigt (APV) function corrects the deviations on the rising edge. Requiring only the central wavelength and bandwidth as user inputs, the simulation results exhibit a high degree of agreement with the experimental data spectra. The model provides a rapid and robust tool for pre-evaluating light sources against regulatory criteria (e.g., >99% of the spectral intensity is in the 400–500 nm band), thereby enhancing the efficiency of experimental design in blue light protection studies.
1 February 2018 in Journal of Physics: Conference Series
For most of the array spectroradiometer, stray light is significant in UV band. Stray light correction of a UV array spectroradiometer is investigated using optical filters. If a group of filters with continuous bandpass are chosen, stray light contribution due to all the bands can be obtained using a numerical algorithm. The array spectroradiometer with the stray light corrected is used to measure the spectral irradiance of several UV lamps. The measurement results are compared to a double monochromator spectroradiometer. When xenon lamp is the array spectroradiometer calibration lamp, after stray light correction, the difference can be improved from nearly 10% to 2.0% in UVC band. When tungsten lamp is the calibration lamp, the difference can be improved from around 90% to less than 20%.
In order to reduce the inconsistency of spectral radiance caused by the aiming area differences between different spectroradiometers, the influence of field of view (FOV) angle and positioning on measurement accuracy was discussed. By establishing the spectral radiance measurement model of sunlight whiteboard and tungsten halogen lamp whiteboard, the differences between the average radiance and central radiance in the field of view of different geometric optical paths were analyzed. Numerical simulation shows that the correction factor of sunlight whiteboard path is only related to the size of FOV angle, while that of tungsten halogen lamp whiteboard path decreases with the increases of the measurement distance. When the distance is 600 mm, the correction factor of 8° and 14° FOV angle changes to 0.993 5 and 0.980 2, respectively. Finally, the experiment verified the influence of the angle error and displacement error on spectral radiance when using the tungsten halogen lamp whiteboard system. The results show that the correction factor presents asymmetry to the horizontal angle error and displacement error, and the difference between the two sides is as high as 2%. Therefore, the measurement results can be corrected according to the FOV angle and geometric positioning, which helps to improve the uncertainty level of spectral radiance measurement.