Alok Kumar Sharma

Dr. Alok Kumar Sharma

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Tan-Hsu TanTan-Hsu Tan
Tan-Hsu Tan
JTJia-Hong Tian
Jia-Hong Tian
ASAlok Kumar Sharma
Alok Kumar Sharma
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
Yung-Fa HuangYung-Fa Huang
Yung-Fa Huang
Activity recognition is one of the significant technologies accompanying the development of the Internet of Things (IoT). It can help in recording daily life activities or reporting emergencies, thus improving the user’s quality of life and safety, and even easing the workload of caregivers. This study proposes a human activity recognition (HAR) system based on activity data obtained via the micro-Doppler effect, combining a two-stream one-dimensional convolutional neural network (1D-CNN) with a bidirectional gated recurrent unit (BiGRU). Initially, radar sensor data are used to generate information related to time and frequency responses using short-time Fourier transform (STFT). Subsequently, the magnitudes and phase values are calculated and fed into the 1D-CNN and Bi-GRU models to extract spatial and temporal features for subsequent model training and activity recognition. Additionally, we propose a simple cross-channel operation (CCO) to facilitate the exchange of magnitude and phase features between parallel convolutional layers. An open dataset collected through radar, named Rad-HAR, is employed for model training and performance evaluation. Experimental results demonstrate that the proposed 1D-CNN+CCO-BiGRU model demonstrated superior performance, achieving an impressive accuracy rate of 98.2%. This outperformance of existing systems with the radar sensor underscores the proposed model’s potential applicability in real-world scenarios, marking a significant advancement in the field of HAR within the IoT framework.

30 March 2025 in Intelligent Systems with Applications
Verified
Journal Article
Open access
LLLi-Hua Li
Li-Hua Li
ASAlok Kumar Sharma
Alok Kumar Sharma
SCSheng-Tzong Cheng
Sheng-Tzong Cheng

12 April 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
ASAlok Kumar Sharma
Alok Kumar Sharma
BWBo-Yan Wu
Bo-Yan Wu
XZXin Zhu
Xin Zhu
CCChun-Ju Chang
Chun-Ju Chang
Jia-Jung WangJia-Jung Wang
Jia-Jung Wang
The gait analysis has been applied in many fields, such as the assessment of falling, force evaluation in sports, and gait disorder detection for neuromuscular diseases. Its main recording techniques include video cameras and wearable sensors. However, the present methods involve measuring surface electromyograms (sEMGs) to analyze muscle activities. The primary goal of this study is to estimate gait parameters under different power capacity of muscle by sEMGs measured from lower limbs. A self-made wireless device recorded sEMGs from two muscles of each foot, and GaitUp Physilog®5 sensors captured gait parameters from 18 participants under running as references. Four features including median frequency (MDF), waveform length (WL), standard deviation (SD), and sample entropy (SampEn), were extracted from the sEMG data. The analysis utilized three machine learning models (Random Forest, CatBoost, XGBoost), evaluated through various evaluation metrics. Additionally, 5-fold cross-validation was conducted to assess the influence of muscle fatigue on the estimation of gait parameters. The results show that all models successfully estimated 20 gait parameters, all showing a Pearson correlation coefficient (PCC) above 0.800. However, the performance of models significantly depends on the condition of muscle fatigue. This study represents a significant advancement in gait analysis, providing a comprehensive method for estimating gait parameters from sEMG signals, with important implications for mobile health applications.

21 August 2023 in Sensors
Verified
Journal Article
Open access
PDF file
BSBadrinathan Sridharan
Badrinathan Sridharan
ASAlok Kumar Sharma
Alok Kumar Sharma
Hae Gyun LimHae Gyun Lim
Hae Gyun Lim
Ultrasound has a deep penetrating ability with minimal or no tissue injury, while cancer-mediated complications during diagnosis, therapy, and surgery have become a serious challenge for clinicians and lead to the severity of the primary condition (cancer). The current study highlights the importance of ultrasound imaging and focused ultrasound therapy during cancer diagnosis, pain reduction, guidance for surgical resection of cancer, and the effectiveness of chemotherapy. We performed the bibliometric analysis on research domains involving ultrasound, cancer management, pain, and other challenges (chemotherapy, surgical guidance, and postoperative care), to observe the trend by which the research field has grown over the years and propose a possible future trend. The data was obtained from the Web of Science, processed, and exported as plain text files for analysis in the Bibliometrix R web interface using the Biblioshiny package. A total of 3248 documents were identified from 1100 journal sources. A total of 390 articles were published in 2022, with almost a 100% growth rate from previous years. Based on the various network analysis, we conclude that the outcome of the constant research in this domain will result in better patient care during the management of various diseases, including cancer and other co-morbidities.

6 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
ASAlok Kumar Sharma
Alok Kumar Sharma
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
XZXin Zhu
Xin Zhu
Wenxi ChenWenxi Chen
Wenxi Chen
This study aims to evaluate leg movement by integrating gait analysis with surface electromyography (sEMG) and accelerometer (ACC) data from the lower limbs. We employed a wireless, self-made, and multi-channel measurement system in combination with commercial GaitUp Physilog® 5 shoe-worn inertial sensors to record the walking patterns and muscle activations of 17 participants. This approach generated a comprehensive dataset comprising 1452 samples. To accurately predict gait parameters, a machine learning model was developed using features extracted from the sEMG signals of thigh and calf muscles, and ACCs from both legs. The study utilized evaluation metrics including accuracy (R2), Pearson correlation coefficient (PCC), root mean squared error (RMSE), mean absolute percentage error (MAPE), mean squared error (MSE), and mean absolute error (MAE) to evaluate the performance of the proposed model. The results highlighted the superiority of the CatBoost model over alternatives like XGBoost and Decision Trees. The CatBoost’s average PCCs for 17 temporospatial gait parameters of the left and right legs are 0.878 ± 0.169 and 0.921 ± 0.047, respectively, with MSE of 7.65, RMSE of 1.48, MAE of 1.00, MAPE of 0.03, and Accuracy (R2-Score) of 0.91. This research marks a significant advancement by providing a more comprehensive method for detecting and analyzing gait statuses.

12 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Jia-Jung WangJia-Jung Wang
Jia-Jung Wang
ASAlok Kumar Sharma
Alok Kumar Sharma
Shing-Hong LiuShing-Hong Liu
Shing-Hong Liu
HZHangliang Zhang
Hangliang Zhang
Wenxi ChenWenxi Chen
Wenxi Chen
TLThung Lip Lee
Thung Lip Lee
This research examines the application of non-invasive acoustic analysis for detecting obstructions in vascular access (fistulas) used by kidney dialysis patients. Obstructions in these fistulas can interrupt essential dialysis treatment. In this study, we utilized a condenser microphone to capture the blood flow sounds before and after angioplasty surgery, analyzing 3819 sound samples from 119 dialysis patients. These sound signals were transformed into spectrogram images to classify obstructed and unobstructed vascular accesses, that is fistula conditions before and after the angioplasty procedure. A novel lightweight two-dimension convolutional neural network (CNN) was developed and benchmarked against pretrained CNN models such as ResNet50 and VGG16. The proposed model achieved a prediction accuracy of 100%, surpassing the ResNet50 and VGG16 models, which recorded 99% and 95% accuracy, respectively. Additionally, the study highlighted the significantly smaller memory size of the proposed model (2.37 MB) compared to ResNet50 (91.3 MB) and VGG16 (57.9 MB), suggesting its suitability for edge computing environments. This study underscores the efficacy of diverse deep-learning approaches in the obstructed detection of dialysis fistulas, presenting a scalable solution that combines high accuracy with reduced computational demands.