Víctor Echarri

Prof. Dr. Víctor Echarri

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Energy and Buildings
Verified
Journal Article
Closed access
JFJesús Feijó-Muñoz
Jesús Feijó-Muñoz
CPCristina Pardal
Cristina Pardal
VEVíctor Echarri
Víctor Echarri
JFJesica Fernández-Agüera
Jesica Fernández-Agüera
RLRafael Assiego de Larriva
Rafael Assiego de Larriva
Alberto MeissAlberto Meiss
Alberto Meiss

11 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MAMaría Dolores Andújar-Montoya
María Dolores Andújar-Montoya
AGAntonio Galiano-Garrigós
Antonio Galiano-Garrigós
VEVíctor Echarri
Víctor Echarri
CMCarlos Rizo Maestre
Carlos Rizo Maestre
Current market conditions characterized by technological changes, increasing regulatory requirements and low funding make current construction management models obsolete. This tendency affects not only the private housing market but also public administration projects, which have large time and budget deviations across the board. As a result, new approaches are needed to improve the efficiency of the construction process, removing extra costs and delivering projects on time. The most representative trends in the construction industry that enable such improvements are both Building Information Modelling paradigm (BIM) and Lean Construction philosophy with one of its associated tools in the field of construction management—the Last Planner System. However, a review of the literature shows the scarcity of works on the synergy of both paradigms taking into account the extensive literature on Lean and BIM individually. This is further accused if we look beyond the theoretical literature reviews. Therefore, this paper is focused on the benefits derived from the synergy of both disciplines and the impacts on project efficiency through a case study of a public construction project at the university of Alicante in order to provide empirical evidence of the benefits and improvements of using BIM at the Look Ahead meetings and of the Last Planner System. Finally, the results of the case study allow us to make a comparison with the data related to cost deviations of other public projects with different uses, built areas, and complexity which were managed with traditional methods of construction.

8 December 2017 in Sensors
Verified
Journal Article
Open access
PDF file
VEVíctor Echarri
Víctor Echarri
AEAlmudena Espinosa-Fernández
Almudena Espinosa-Fernández
CMCarlos Rizo Maestre
Carlos Rizo Maestre
Opaque enclosures of buildings play an essential role in the level of comfort experienced indoors and annual energy demand. The impact of solar radiation and thermal inertia of the materials that make up the multi-layer enclosures substantially modify thermal transmittance behaviour of the enclosures. This dynamic form of heat transfer, additionally affected by indoor HVAC systems, has a substantial effect on the parameters that define comfort. It also has an impact on energy demand within a daily cycle as well as throughout a one-year use cycle. This study describes the destructive monitoring of an existing block of flats located in Alicante. Once the enclosure was opened, sensors of temperature (PT100), air velocity, and relative humidity were located in the different layers of the enclosure, as well as in the interior and exterior surfaces. A pyranometer was also installed to measure solar radiation levels. A temperature data correction algorithm was drawn up to address irregularities produced in the enclosure. The algorithm was applied using a Raspberry Pi processor in the data collection system. The comparative results of temperature gradients versus non-destructive monitoring systems are presented, providing measures of the transmittance value, surface temperatures and indoor and outdoor air temperatures. This remote sensing system can be used in future studies to quantify and compare the energy savings of different enclosure construction solutions.

13 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
JFJesús Feijó-Muñoz
Jesús Feijó-Muñoz
Irene Poza-CasadoIrene Poza-Casado
Irene Poza-Casado
Roberto Alonso Gonzalez-LezcanoRoberto Alonso Gonzalez-Lezcano
Roberto Alonso Gonzalez-Lezcano
CPCristina Pardal
Cristina Pardal
VEVíctor Echarri
Víctor Echarri
Alberto MeissAlberto Meiss
Alberto Meiss
Air leakage and its impact on the energy performance of dwellings has been broadly studied in countries with cold climates in Europe, US, and Canada. However, there is a lack of knowledge in this field in Mediterranean countries. Current Spanish building regulations establish ventilation rates based on ideal airtight envelopes, causing problems of over-ventilation and substantial energy losses. The aim of this paper is to develop a methodology that allows the characterization of the envelope of the housing stock in Spain in order to adjust ventilation rates taking into consideration air leakage. A methodology that is easily applicable to other countries that consider studying the airtightness of the envelope and its energetic behaviour improvement is proposed. A statistical sampling method has been established to determine the dwellings to be tested, considering relevant variables concerning airtightness: climate zone, year of construction, and typology. The air leakage rate is determined using a standardized building pressurization technique according to European Standard EN 13829. A representative case study has been presented as an example of the implementation of the designed methodology and results are compared to preliminary values obtained from the database.

8 July 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
VEVíctor Echarri
Víctor Echarri
CSCristina Sotos-Solano
Cristina Sotos-Solano
AEAlmudena Espinosa-Fernández
Almudena Espinosa-Fernández
RPRaúl Prado-Govea
Raúl Prado-Govea
Few houses have been built in the Spanish Mediterranean in accordance with the Passivhaus (PH) standard. This standard is adapted to the continental climates of Central Europe and thorough studies are necessary to apply this standard in Spain, especially in the summer. High relative air humidity levels in coastal areas and solar radiation levels of west-facing façades require adapted architectural designs, as well as greater control of air renewal and dehumidification. A priori, energy consumptions undergo big variations. In this study, the construction of a single-family house in the Spanish Levante was analysed. All enclosure layers were monitored using sensors of surface temperature, solar radiation, indoor and outdoor air temperature, relative humidity, and air speed. The thermal behaviour of the façade enclosure and air infiltration through the enclosure were examined using the blower door test and impacts on annual energy demand were quantified. Using simulation tools, improvements are proposed, and the results are compared with examples of PH housing in other geographical areas. The annual energy demand of PH housing was 69.19% below the usual value for buildings in the Mediterranean region. Very thick thermal insulation and low values of airtightness could be applied to the envelope, which would work very well in the winter. These technique solutions could provide optimal comfort conditions with a well-designed air conditioning system in summer and low energy consumption.

CMCarlos Rizo Maestre
Carlos Rizo Maestre
VEVíctor Echarri
Víctor Echarri
In healthy buildings, it is considered essential to quantify air quality. One of the most fashionable indicators is radon gas. To determine the presence of this element, which is harmful to health, in the environment, the composition of the soil is studied. The presence of radon gas within a building depends both on the terrain in which it is located and on the composition of the materials of which it is composed, and not as was previously believed, only by the composition of the soil (whether granitic or not). Many countries are currently studying this phenomenon, including Spain where the building regulations regarding the accumulation of radon gas, do not list in their technical codes, the maximum dose that can a building can hold so that it is not harmful to people and the measures to correct excessive accumulation. Therefore, once the possible existence of radon in any underground building has been verified, regardless of the characteristics of the soil, the importance of defining and unifying the regulations on different levels of radon in all architectural constructions is evident. Medical and health science agencies, including the World Health Organization, consider that radon gas is a very harmful element for people. This element, in its gaseous state, is radioactive and it is present in almost soils in which buildings are implanted. Granitic type soils present higher levels of radon gas. Non-granitic soils have traditionally been considered to have very low radon levels. However, this paper demonstrates the relevant presence of radon in non-granitic soils, specifically in clayey soils, by providing the results of research carried out in the underground air raid shelter at Balmis Square in Alicante (Spain). The results of the measurements of radon accumulation in the Plaza Balmis shelter are five times higher than those obtained in a similar ungrounded building. This research addresses the constructive typology of an under-ground building and the radon presence in its interior obtained using rigorous measurement techniques.