Rafael Assiego de Larriva

Dr. Rafael Assiego de Larriva

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2019 in Energy and Buildings
Verified
Journal Article
Closed access
JFJesús Feijó-Muñoz
Jesús Feijó-Muñoz
CPCristina Pardal
Cristina Pardal
VEVíctor Echarri
Víctor Echarri
JFJesica Fernández-Agüera
Jesica Fernández-Agüera
RLRafael Assiego de Larriva
Rafael Assiego de Larriva
Alberto MeissAlberto Meiss
Alberto Meiss

1 February 2014 in Energy and Buildings
Verified
Journal Article
Closed access
RLRafael Assiego de Larriva
Rafael Assiego de Larriva
GRGloria Calleja Rodríguez
Gloria Calleja Rodríguez
JLJosé Manuel Cejudo López
José Manuel Cejudo López
Marco RaugeiMarco Raugei
Marco Raugei
PPPERE FULLANA i PALMER
PERE FULLANA i PALMER

13 March 2018 in Energies
Verified
Journal Article
Open access
PDF file
JFJesús Feijó-Muñoz
Jesús Feijó-Muñoz
Irene Poza-CasadoIrene Poza-Casado
Irene Poza-Casado
Roberto Alonso Gonzalez-LezcanoRoberto Alonso Gonzalez-Lezcano
Roberto Alonso Gonzalez-Lezcano
CPCristina Pardal
Cristina Pardal
VEVíctor Echarri
Víctor Echarri
Alberto MeissAlberto Meiss
Alberto Meiss
Air leakage and its impact on the energy performance of dwellings has been broadly studied in countries with cold climates in Europe, US, and Canada. However, there is a lack of knowledge in this field in Mediterranean countries. Current Spanish building regulations establish ventilation rates based on ideal airtight envelopes, causing problems of over-ventilation and substantial energy losses. The aim of this paper is to develop a methodology that allows the characterization of the envelope of the housing stock in Spain in order to adjust ventilation rates taking into consideration air leakage. A methodology that is easily applicable to other countries that consider studying the airtightness of the envelope and its energetic behaviour improvement is proposed. A statistical sampling method has been established to determine the dwellings to be tested, considering relevant variables concerning airtightness: climate zone, year of construction, and typology. The air leakage rate is determined using a standardized building pressurization technique according to European Standard EN 13829. A representative case study has been presented as an example of the implementation of the designed methodology and results are compared to preliminary values obtained from the database.