Irfan Sugianto

Dr. Irfan Sugianto


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 January 2018 in The Open Dentistry Journal
Verified
Journal Article
Open access
PDF file
BBBabatunde O. Bamgbose
Babatunde O. Bamgbose
ASAkiko Sato
Akiko Sato
YYYoshinobu Yanagi
Yoshinobu Yanagi
MHMiki Hisatomi
Miki Hisatomi
YTYohei Takeshita
Yohei Takeshita
JAJunichi Asaumi
Junichi Asaumi
Background: We herein described a rare case of schwannoma of the hypoglossal nerve in the submandibular region with diagnostic imaging and histopathological findings.Case Report: A 31-years-old woman has had a palpable firm, rubbery, freely mobile mass in the submandibular region. Of imaging, MR images showed homogeneous isointensity on T1-weighted imaging (T1-WI), heterogeneous hypointensity on T2-WI, heterogeneous hyperintensity on short T1 inversion recovery (STIR), and heterogeneous enhancement on contrast-enhanced T1-WI. A clear capsule was observed on the margin and showed hypointense on T2-WI. Dynamic MRI showed heterogeneous gradual increased enhancement. The uptake of contrast medium was regionally slow. Diagnostic imaging using CT and MRI was suspected of salivary gland tumor or neurogenic tumor. In consideration of imaging diagnosis, a pleomorphic adenoma or a schwannoma was suspected. Final diagnosis was confirmed on the basis of histopathological finding and intraoperative findings.Conclusion: 1. Histopathologic examination is inevitable, because MR findings are not specific.2. Schwannomas were said to have specific MRI properties, including specific signs (split-fat sign, fascicular sign, target sign). However, they are not always observed.3. This case confirmed the differential diagnosis on the basis of the intraoperative finding that the tumor was continuous with the hypoglossal nerve.

31 October 2022 in Sinnun Maxillofacial Journal
Verified
Journal Article
Open access
PDF file
MRMuhammad Alif Reski
Muhammad Alif Reski
ISIrfan Sugianto
Irfan Sugianto
Pendahuluan: Pemeriksaan radiografi periapikal merupakan salah satu pemeriksaan rutin yang dilakukan untuk membantu menegakkan diagnosis dan rencana perawatan, salah satunya dengan teknik bisecting. Pada pemeriksaan bisecting memiliki bermacam-macam potensi terjadinya kesalahan dalam pengambilan yang menyebabkan pengulangan pengambilan radiograf dan memberikan paparan radiasi yang tidak perlu. Tujuan: untuk mengidentifikasi kemungkinan kesalahan pemeriksaan radiografi periapikal khususnya teknik bisecting. Metode: studi literatur yang mengumpulkan literatur dari database jurnal yang memenuhi topik penelitian ini. Hasil: 11 artikel melaporkan kesalahan hasil teknik periapikal bisecting seperti Overlapping, Apex dan Crown Cutting, Blurred, Cone Cutting, Elongation, Foreshortening dan Double Expossure, jenis kesalahan pemeriksaan teknik periapikal membagi dua adalah kesalahan posisi, kesalahan eksposur, kesalahan teknis dan kesalahan pasien. Kesimpulan: Jenis dan penyebab kesalahan dari radiografi periapikal digital dengan teknik Bisecting memiliki peran penting dalam meningkatkan prinsip ALARA (As Low as Achievable Reasonable) kepada pasien, klinisi dan teknisi untuk mengurangi paparan radiasi dan meningkatkan kualitas radiografi.

4 August 2023 in Current Oncology
Verified
Journal Article
Open access
PDF file
WAWlla Al-Hammad
Wlla Al-Hammad
MKMasahiro Kuroda
Masahiro Kuroda
RKRyo Kamizaki
Ryo Kamizaki
NTNouha Tekiki
Nouha Tekiki
HIHinata Ishizaka
Hinata Ishizaka
JAJunichi Asaumi
Junichi Asaumi
Deep inspiration breath-hold (DIBH) is an excellent technique to reduce the incidental radiation received by the heart during radiotherapy in patients with breast cancer. However, DIBH is costly and time-consuming for patients and radiotherapy staff. In Asian countries, the use of DIBH is restricted due to the limited number of patients with a high mean heart dose (MHD) and the shortage of radiotherapy personnel and equipment compared to that in the USA. This study aimed to develop, evaluate, and compare the performance of ten machine learning algorithms for predicting MHD using a patient’s body mass index and single-slice CT parameters to identify patients who may not require DIBH. Machine learning models were built and tested using a dataset containing 207 patients with left-sided breast cancer who were treated with field-in-field radiotherapy with free breathing. The average MHD was 251 cGy. Stratified repeated four-fold cross-validation was used to build models using 165 training data. The models were compared internally using their average performance metrics: F2 score, AUC, recall, accuracy, Cohen’s kappa, and Matthews correlation coefficient. The final performance evaluation for each model was further externally analyzed using 42 unseen test data. The performance of each model was evaluated as a binary classifier by setting the cut-off value of MHD ≥ 300 cGy. The deep neural network (DNN) achieved the highest F2 score (78.9%). Most models successfully classified all patients with high MHD as true positive. This study indicates that the ten models, especially the DNN, might have the potential to identify patients who may not require DIBH.

1 February 2018
Verified
Journal Article
Closed access
YYYuuki Yoshimura
Yuuki Yoshimura
MKMasahiro Kuroda
Masahiro Kuroda
ISIrfan Sugianto
Irfan Sugianto
BBBabatunde O. Bamgbose
Babatunde O. Bamgbose
KMKanae Miyahara
Kanae Miyahara
JAJunichi Asaumi
Junichi Asaumi

7 December 2023 in Diagnostics
Verified
Journal Article
Open access
PDF file
YFYuka Fukumura
Yuka Fukumura
MKMasahiro Kuroda
Masahiro Kuroda
SYSuzuka Yoshida
Suzuka Yoshida
YNYoshihide Nakamura
Yoshihide Nakamura
YNYUKI NAKAMITSU
YUKI NAKAMITSU
JAJunichi Asaumi
Junichi Asaumi
We evaluated the usefulness of simple diffusion kurtosis (SD) imaging, which was developed to generate diffusion kurtosis images simultaneously with an apparent diffusion coefficient (ADC) map for 27 cystic disease lesions in the head and neck region. The mean kurtosis (MK) and ADC values were calculated for the cystic space. The MK values were dentigerous cyst (DC): 0.74, odontogenic keratocyst (OKC): 0.86, ranula (R): 0.13, and mucous cyst (M): 0, and the ADC values were DC: 1364 × 10−6 mm2/s, OKC: 925 × 10−6 mm2/s, R: 2718 × 10−6 mm2/s, and M: 2686 × 10−6 mm2/s. The MK values of DC and OKC were significantly higher than those of R and M, whereas their ADC values were significantly lower. One reason for the characteristic signal values in diffusion-weighted images of DC may be related to content components such as fibrous tissue and exudate cells. When imaging cystic disease in the head and neck region using SD imaging, the maximum b-value setting at the time of imaging should be limited to approximately 1200 s/mm2 for accurate MK value calculation. This study is the first to show that the MK values of DC are characteristically higher than those of other cysts.

20 April 2017 in Oral Radiology
Verified
Journal Article
Closed access
PDF file
BBBabatunde O. Bamgbose
Babatunde O. Bamgbose
MSMuhammad A. Suwaid
Muhammad A. Suwaid
MKMohammad Abubakar Kaura
Mohammad Abubakar Kaura
ISIrfan Sugianto
Irfan Sugianto
MHMiki Hisatomi
Miki Hisatomi
JAJunichi Asaumi
Junichi Asaumi