Thomas D. Wang

Dr. Thomas D. Wang


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2015 in Biotechnology Letters
Verified
Journal Article
Closed access
PDF file
DZDan Zhang
Dan Zhang
HJHuan Jia
Huan Jia
YWYan Wang
Yan Wang
WLWei-Ming Li
Wei-Ming Li
YHYingchun Hou
Yingchun Hou
SLShaoying Lu
Shaoying Lu

13 February 2014 in Journal of Microelectromechanical Systems
Verified
Journal Article
Closed access
ZQZhen Qiu
Zhen Qiu
CRChoong-Ho Rhee
Choong-Ho Rhee
JCJongsoo Choi
Jongsoo Choi
TWThomas D. Wang
Thomas D. Wang
KOKenn Oldham
Kenn Oldham
A thin-film piezoelectric microactuator using a novel combination of active vertical translational scanning and passive resonant rotational scanning is presented. Thin-film lead-zirconate-titanate unimorph bending beams surrounding a central platform provide nearly 200-μm displacement at 18 V with bandwidth greater than 200 Hz. Inside the platform, a mirror mount, or mirror surface, supported by silicon dioxide spring beams can be excited to resonance by low-voltage; high-frequency excitation of the outer PZT beams. Over ±5.5° mechanical resonance is obtained at 3.8 kHz and ±2 V. The combination of large translational vertical displacements and high-speed rotational scanning is intended to support real-time cross-sectional imaging in a dual axes confocal endomicroscope.

1 September 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MBMayur Birla
Mayur Birla
XDXiyu Duan
Xiyu Duan
HLHaijun Li
Haijun Li
MLMiki Lee
Miki Lee
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
This article applies image processing metrics to tracking of perturbations in mechanical phase delay in a multiaxis microelectromechanical system scanner. The compact mirror is designed to scan a laser beam in a Lissajous pattern during the collection of endoscopic confocal fluorescence images, but environmental perturbations to the mirror dynamics can lead to image registration errors and blurry images. A binarized, threshold-based blur metric and variance-based sharpness metric are introduced for detecting scanner phase delay. Accuracy of local optima of the metric for identification of phase delay is examined, and relative advantages for processing accuracy and computational complexity are assessed. Image reconstruction is demonstrated using both generic images and sample tissue images, with significant improvement in image quality for tissue imaging. Implications of nonideal Lissajous scan effects on phase detection and image reconstruction are discussed.

12 March 2020 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
YCYi Chen
Yi Chen
MLMiki Lee
Miki Lee
MBMayur Bhushan Birla
Mayur Bhushan Birla
HLHaijun Li
Haijun Li
GLGaoming Li
Gaoming Li
KOKenn Oldham
Kenn Oldham
In this article, we present a method to estimate high-frequency rotary motion of a highly compact electrostatic microscanner using the same electrodes for both actuation and sensing. The accuracy of estimated rotary motion is critical for reducing blur and distortion in image reconstruction applications with the microscanner given its changing dynamics due to perturbations such as temperature. To overcome the limitation that no dedicated sensing electrodes are available in the proposed applications due to size constraints, the method adopts electromechanical amplitude modulation to separate motion signal from parasitic capacitance feedthrough, and a novel nonlinear measurement model is derived to characterize the relationship between large out-of-plane angular motion and circuit output. To estimate motion, an extended Kalman filter and an unscented Kalman filter are implemented, incorporating a process model based on the microscanner's parametric resonant dynamics and the measurement model. Experimental results show that compared to estimation without using the measurement model, our method can improve the rotary motion estimation accuracy of the microscanner significantly, with a reduction of root-mean-square error (RMSE) in phase shift of 86.1%, and a reduction of RMSE in angular position error of 78.5%.

24 December 2008 in Cancer Biomarkers
Verified
Journal Article
Closed access
PDF file
SLShaoying Lu
Shaoying Lu
TWThomas D. Wang
Thomas D. Wang
The emergence of in vivo cancer biomarkers is promising tool for early detection, risk stratification, and therapeutic intervention in the esophagus, where adenocarcinoma is increasing at a rate that is faster than any other in industrialized nations

23 August 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
YJYang Jiang
Yang Jiang
JCJing Chen
Jing Chen
CGChen Gong
Chen Gong
TWThomas D. Wang
Thomas D. Wang
ESEric Seibel
Eric Seibel
Esophageal adenocarcinoma (EAC) is a deadly cancer that is rising rapidly in incidence. The early detection of EAC with curative intervention greatly improves the prognoses of patients. A scanning fiber endoscope (SFE) using fluorescence-labeled peptides that bind rapidly to epidermal growth factor receptors showed a promising performance for early EAC detection. Target-to-background (T/B) ratios were calculated to quantify the fluorescence images for neoplasia lesion classification. This T/B calculation is generally based on lesion segmentation with the Chan–Vese algorithm, which may require hyperparameter adjustment when segmenting frames with different brightness and contrasts, which impedes automation to real-time video. Deep learning models are more robust to these changes, while accurate pixel-level segmentation ground truth is challenging to establish in the medical field. Since within our dataset the ground truth contained only a frame-level diagnosis, we proposed a computer-aided diagnosis (CAD) system to calculate the T/B ratio in real time. A two-step process using convolutional neural networks (CNNs) was developed to achieve automatic suspicious frame selection and lesion segmentation for T/B calculation. In the segmentation model training for Step 2, the lesion labels were generated with a manually tuned Chan–Vese algorithm using the labeled and predicted suspicious frames from Step 1. In Step 1, we designed and trained deep CNNs to select suspicious frames using a diverse and representative set of 3427 SFE images collected from 25 patient videos from two clinical trials. We tested the models on 1039 images from 10 different SFE patient videos and achieved a sensitivity of 96.4%, a specificity of 96.6%, a precision of 95.5%, and an area under the receiver operating characteristic curve of 0.989. In Step 2, 1006 frames containing suspicious lesions were used for training for fluorescence target segmentation. The segmentation models were tested on two clinical datasets with 100 SFE frames each and achieved mean intersection-over-union values of 0.89 and 0.88, respectively. The T/B ratio calculations based on our segmentation results were similar to the manually tuned Chan–Vese algorithm, which were 1.71 ± 0.22 and 1.72 ± 0.28, respectively, with a p-value of 0.872. With the graphic processing unit (GPU), the proposed two-step CAD system achieved 50 fps for frame selection and 15 fps for segmentation and T/B calculation, which showed that the frame rejection in Step 1 improved the diagnostic efficiency. This CAD system with T/B ratio as the real-time indicator is designed to guide biopsies and surgeries and to serve as a reliable second observer to localize and outline suspicious lesions highlighted by fluorescence probes topically applied in organs where cancer originates in the epithelia.