Eduardo José Selva-Otaolaurruchi

Dr. Eduardo José Selva-Otaolaurruchi

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
AMAlejandra Baima Moscardó
Alejandra Baima Moscardó
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
JMJosé María Montiel-Company
José María Montiel-Company
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
Background: The aim of this systematic review and meta-analysis was to determine the wear sustained in the natural antagonist tooth in cases of full-coverage fixed-base prosthetic restorations or monolithic zirconia tooth-supported crowns, as well as to determine the wear in the restoration itself, both in the short- and medium-term and considering the factors that may influence wear. Material and methods: A systematic literature review and meta-analysis, based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) recommendations, of clinical studies that evaluated wear in antagonist teeth in relation to fixed-prosthesis monolithic zirconia crowns. A total of 5 databases were consulted in the literature search: Pubmed-Medline, Cochrane, Scopus, Embase and Web of Science (WOS). After eliminating duplicated articles and applying the inclusion criteria, eight articles were selected for the qualitative analysis and four for the quantitative analysis. Results: Mean maximum wear of the antagonist tooth in relation to monolithic zirconia crowns of magnitude 95.45 µm (CI at 95% 79.57–111.33) was observed. By using a meta-regression model (R2 = 0.92) the significant effect of time in maximum wear rate (p < 0.001) was observed, estimated at 6.13 µm per month (CI at 95% 3.99–8.27). Furthermore, monolithic zirconia crowns are subject to a mean maximum wear of 58.47 µm (CI 95% 45.44–71.50). By using a meta-regression model (R2 = 0.53) the significant effect of time in the maximum wear value was observed (p = 0.053), estimated at 3.40 µm per month (CI al 95% −0.05–6.85). Conclusions: Monolithic zirconia crowns lead to a progressive maximum wear of the antagonist tooth over time which is greater than the maximum wear sustained in the crown itself. It is not possible to establish an objective and quantitative objection in relation to natural enamel wear or metal–ceramic crowns.

20 March 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CBCarla Fons Badal
Carla Fons Badal
AFAntonio Fons-Font
Antonio Fons-Font
CLCARLOS LABAIG
CARLOS LABAIG
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
Background: Calculus accumulation varies widely between individuals. Dental calculus has been associated with the principal periodontal diseases. The aim of this study was to analyze individual characteristics, and salivary and microbiological parameters among patients considered to be rapid calculus formers and patients who form calculus slowly. Methods: Individual characteristics were recorded in a sample of 74 patients (age, sex, smoking, periodontal diagnosis, and dental crowding), as well as salivary parameters (unstimulated saliva flow, pH, and biochemical analysis of saliva) and microbiological parameters (by means of semi-quantitative polymerase chain reaction (PCR) analysis). Results: A statistically significant association (p = 0.002) was found between the rate of calculus formation and the diagnosis of periodontal disease. A greater presence of dental crowding was observed among the group of rapid calculus formers. Urea and phosphorus levels were higher among rapid calculus formers. Regarding microbiological parameters, differences were found in Streptococcus mutans, this being higher in the group of slow formers. Conclusions: Rapid calculus formation appears to be linked to patients diagnosed with more severe periodontal diseases. Rapid calculus-forming patients present more dental crowding and a lower proportion of S. mutans.

17 January 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RLRAQUEL LEON
RAQUEL LEON
JMJosé María Montiel-Company
José María Montiel-Company
CBCarlos Bellot-Arcis
Carlos Bellot-Arcis
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
Background: The objective of this systematic review and meta-analysis was to analyze the periodontal behavior around teeth prepared with horizontal finishing crowns supporting fixed metal-ceramic and zirconia full coverage crowns and fixed partial dentures (FDPs). Materials and methods: An electronic search was conducted to locate relevant clinical trials in four databases: PubMed, Embase, Cochrane, and Scopus. A manual search was made in the reference sections of the articles identified for any additional articles. No restrictions were applied regarding year of publication or language. The following variables were considered in quantitative and qualitative analysis: probing pocket depth (PPD); probing attachment level (PAL); plaque control record (PCR); bleeding on probing (BOP); and gingival margin migration. Results: Twenty articles were selected for qualitative synthesis, and of these, nine underwent meta-analysis. Higher PCR was found in control teeth, while BOP, PPD, and PAL were higher around teeth prepared with horizontal finishing lines supporting complete coverage crowns/FDPs Gingival migration results were the clearest manifestation of compromised periodontal health around teeth prepared with horizontal finishing lines. Conclusions: Meta-analysis revealed that teeth prepared with horizontal finishing lines supporting crowns and FDPs present more periodontal disorders than untreated control teeth.

19 March 2020 in Medicina
Verified
Journal Article
Open access
PDF file
JMJose Mañes
Jose Mañes
LFLucia Fernandez-Estevan
Lucia Fernandez-Estevan
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
CLCarlos Labaig-Rueda
Carlos Labaig-Rueda
MSMª Fernanda Sola-Ruiz
Mª Fernanda Sola-Ruiz
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
Background and objectives: To compare the medium- to long-term mechanical behavior of overdentures with two different retention systems: overdentures with Locator® axial retention, and vertical insertion overdentures with bar retention, used to rehabilitate edentulous maxillar. Material and Methods: This prospective study assessed patients presenting complete maxillary edentulism, rehabilitated by means of implant-supported overdentures (n = 20), 10 with Locator® axial retention (ODA group) and 10 with overdentures on bars (ODB group). Patients also completed a questionnaire to determine their satisfaction with treatment. Results: The mean follow-up time in both groups was 11.4 years, with follow-up times in both groups ranging from 5 to 14 years. The ODA group suffered mechanical complications such as retention loss, need for nylon retention insert changes, resin fracture, and need for relining. In the ODB group, prosthetic dental wear, screw loosening, and complete prosthetic failure were more common. A total of 19 implants failed (23.8%); of these, 11 were in the ODA group (failure rate = 27.5%) and eight in the ODB group (failure rate = 20%). The patient satisfaction questionnaire obtained a mean score of 7.9 out of 10 in the ODA group, and 9.75 in the ODB group. Conclusions: in rehabilitations of edentulous maxillar by means of implant-supported overdentures, both the systems assessed were shown to be effective in the medium to long term. Patients expressed a high level of satisfaction with the treatments received.

24 November 2023 in Materials
Verified
Journal Article
Open access
PDF file
GSGisela Senent-Vicente
Gisela Senent-Vicente
MBMar Baixauli-López
Mar Baixauli-López
EGEva González-Angulo
Eva González-Angulo
LFLuisa Fernández-Bravo
Luisa Fernández-Bravo
ÁZÁlvaro Zubizarreta-Macho
Álvaro Zubizarreta-Macho
Rubén Agustín PanaderoRubén Agustín Panadero
Rubén Agustín Panadero
Statement of problem: The extraction of fractured abutment screws can be a difficult challenge to overcome. Purpose: To compare the removal capacity, dental implant connection damage, and time required to remove the fractured abutment screws between three drilling techniques and a conventional method. Materials and methods: A total of 180 prefabricated screw-retained abutments were intentionally fractured in internal connection dental implants after being subjected to a cyclic load and a static compression load. Afterwards, three operators randomly removed the fractured abutment screws with the following drilling techniques and a conventional method: A: a conventional technique using an exploration probe and ultrasonic appliance (n = 45), Rhein83® (n = 45); B: Sanhigia® (n = 45); C: Phibo® (n = 45). Two-way ANOVA models were estimated to evaluate the mean time according to the method and operator used. Results: The probability of removal of the screws with mobility was twelve times higher than that of the screws without mobility (OR = 12.4; p < 0.001). The success rate according to the operators did not show statistically significant differences (p = 0.371). The location of the fractured screw did not affect removal success (p = 0.530). The internal thread of the implant was affected after the removal process in 9.8% of the cases. The mean extraction time was 3.17 ± 2.52 min. The Rhein83® method showed a success rate of 84.4%, followed by the Phibo® and conventional methods (71.1%) and the Sanhigia® method (46.7%). Conclusions: The Rhein83® drilling technique increases the removal probability of fractured abutment screws. The initial mobility of the fragment is also a significant factor in the removal success.

1 January 2016 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
KLK Ladetzki
K Ladetzki
RMR Mateos-Palacios
R Mateos-Palacios
APA Pascual-Moscardo
A Pascual-Moscardo
ESEduardo José Selva-Otaolaurruchi
Eduardo José Selva-Otaolaurruchi
For implant-supported hybrid prostheses, high mastication forces and reduced acrylic resin thickness over a metal substructure often cause failures arising from tooth or resin fractures. To assay fracture resistance of artificial teeth and resin in implant-supported hybrid prostheses in relation to the titanium structure and retention design supporting teeth. 40 specimens bearing incisors were divided into four groups according to the titanium structure supporting the teeth and the type of load force applied: Group I (Control; n=10): Application of static loading to ten incisors set over a metal structure with internal retention. Group II (Control; n=10): Application of static loading to ten incisors set over a metal structure with external retention. The remaining study specimens (n=20) were subjected to 120,000 masticatory and thermal cycles in a chewing simulator. Afterwards, static loading was applied until the point of fracture using an Instron machine. Group III (Study; n=10): Application of dynamic and static loading to ten incisors set over a metal structure with internal retention. Group IV (Study; n=10): Application of dynamic and static loading to ten incisors set over a metal structure with external retention. Data obtained for the four groups was analyzed and compared, determining the type of fracture (cohesive or adhesive) using a reflected light microscope. Statistical analysis confirmed that there were significant differences in fracture resistance between the four groups. External retention was found to have more fracture resistance than the internal retention. Hybrid prostheses with titanium substructures and external retention obtained significantly better results than samples with internal retention. Chewing simulator, thermocycler, fatigue, implant-supported hybrid prosthesis, acrylic teeth, fracture, metal structure design.