Martin Aaron Sanchez Barajas

Mr. Martin Aaron Sanchez Barajas

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2023 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
MBMartin Aaron Sanchez Barajas
Martin Aaron Sanchez Barajas
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Air pollution is a critical public health problem that has increased during the past decades. High levels of air pollution have affected natural environments and people’s health, causing significant problems and, in severe cases, premature death. A growing trend called “Personal air monitoring” has become important for prevention of and reduction in exposure to air pollutants. The development of personal particulate matter sensors is still a topic of study among the scientific community. Some important identified challenges are improving the sample rate, precision, stability, dimensions and costs, making personal monitoring of air quality affordable. This work proposes the development of a low-cost particulate matter optical sensor to count the number of particles in real time using the Arduino platform and wireless transmission. Our results demonstrated that using a digital input of the microcontroller instead of the analog–digital converter, after conditioning the sensor signal, allows a very high max particle count, which can be compared to that of expensive sensors. In addition, particulate matter (PM) measurements were compared with a GP2Y1014AU0F dust sensor to validate the accuracy of the sensor.

12 October 2024 in Atmosphere
Verified
Journal Article
Open access
PDF file
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
MRMarco Antonio Reyna
Marco Antonio Reyna
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
Air pollution is recognized by the World Health Organization as the major environmental threat; therefore, air quality is constantly being monitored by monitoring stations. However, the most common atmospheric pollutants being monitored do not include pollen. Among the reasons for the lack of pollen control is that there are different types and sizes of pollen. The largest particles commonly being monitored by air monitoring stations have a maximum aerodynamic diameter of 10 microns, while the aerodynamic diameter of most pollen grains is known to range from 10 to 100 microns. For this reason, most pollen is not being detected by air monitoring stations. For the patents found in a literature review, monitoring pollen concentration in the air requires the discrimination of pollen grains from particulate matter of a similar size, as well as the identification of the type of pollen grains detected, since different pollen types may produce different effects, such as allergic reactions, asthma, and lung cancer, in exposed people. In this work, 15 patent documents regarding pollen monitoring were identified and reviewed using three search engines: Google Patents, WIPO’s PatentScope, and the United States Patent and Trademark Office (USPTO) database. The extracted data from the patents included whether they differentiate pollen type, pollen size, and sensor type and whether they provide real-time data. The results show that 93.33% of the patents identify pollen type, while 80% of the patents identify pollen size. Most of the patents use light-scattering and image sensors and use image processing techniques to analyze particles. Furthermore, 40% of the patents were found to implement artificial intelligence. Further, it was found that only nine patents provide real-time data, which is an important feature of an air monitoring system.

25 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
OBOscar Eduardo Barreras-Calderon
Oscar Eduardo Barreras-Calderon
Nowadays, some of the most severe problems faced by health institutions are related to people’s mental health. According to the World Health Organization, approximately one billion people lived with a condition that affected their mental health in 2020, where depression, anxiety, and stress represent the most common examples. Furthermore, according to the American Psychological Association, stress aggravates the symptoms of depression and anxiety, besides having negative effects on the cardiovascular, respiratory, muscular, nervous, reproductive, endocrine, and gastrointestinal systems. It is estimated that during the COVID-19 pandemic, the number of global cases of major depressive disorder and anxiety disorders increased by 53.2 million and 76.2 million, respectively. Psychophysiology and other health disciplines, such as psychology, neurology, psychiatry, and physiotherapy, provide quantitative data from physiological signals. These signals are acquired through specialized systems that are often very expensive, with most being closed-source hardware and software. This work proposes the development of a low-cost prototype for the acquisition and visualization of a patient’s HR, ECG, EMG, GSR, and body temperature biosignals using the MAX30102, ECG AD8232, EMG Muscle T084, Grove GSR sensor, and LM35 AFEs breakout boards, respectively. Signal acquisition tests were performed with each sensor without post-processing or filtering. The test results prove that the biosignals acquired by the prototype present usability, correct morphology, stability, and can operate without errors for up to 12 h. This is expected to provide an affordable alternative to biosignal acquisition systems for educational and research institutions, offering users a similar experience to that provided by high-cost equipment, thus benefiting the training of studies.

21 September 2025 in Environments
Verified
Journal Article
Open access
PDF file
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MBMartin Aaron Sanchez Barajas
Martin Aaron Sanchez Barajas
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
The health impact of air pollutants has generated a trend in the design and manufacture of portable, personal and fixed PM monitoring systems to help reduce exposure to air pollutants. However, these devices still need to be improved and properly evaluated to compete with environmental monitors in the market. In this work, a test chamber with controlled environmental conditions and wireless connectivity is developed for the evaluation of low-cost portable and personal PM sensors. The developed system ensures rapid evaluation tests ranging from seconds to hours to corroborate prolonged operation and correct calibration. The system is controlled by a Python-based graphical user interface (GUI) and monitors PM concentration, altitude, relative humidity, atmospheric pressure, illuminance, and temperature measurements. Fifty measurement tests with a duration of 10 min each were conducted to ensure robust performance and data transfer. Subsequently, four calibration tests were conducted using two SENSIRION SPS30 (SPS A and SPS B) personal PM sensors and two PMS5003 (PMS A and PMS B) personal PM sensors. The Prana Air PAS-OUT-01 sensor served as the reference to calculate the correlations and the descriptive statistics between each sensor to be calibrated. A contamination source was employed utilizing a monodispersed aerosol generator for 0.46 µm latex polystyrene particle atomization. Linear regression was applied during the calibration to determine the calibration coefficients, which were then used to adjust the sensor readings in the respective code and descriptive statistics of the sensor calibration tests were calculated. For the PMS5003 sensors, the Pearson correlation coefficients (r) after calibration were PMS A: 0.9870 and PMS B: 0.9898 compared to their uncalibrated values of PMS A: 0.9828 and PMS B: 0.9863. In contrast, the uncalibrated SPS A sensor initially had a correlation of 0.9939, which slightly decreased to 0.9917 after calibration. Meanwhile, the uncalibrated SPS B sensor showed a correlation of 0.9422, which improved to 0.9715 after calibration.

24 October 2022
Verified
Book Chapter
Closed access
PDF file
MBMartin Aaron Sanchez Barajas
Martin Aaron Sanchez Barajas
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Nestor Alexander Zermeño CamposNestor Alexander Zermeño Campos
Nestor Alexander Zermeño Campos

4 August 2026 in Data in Brief
Verified
Journal Article
Open access
OBOscar E. Barreras
Oscar E. Barreras
DCDaniel Cuevas-González
Daniel Cuevas-González
MRMarco A. Reyna
Marco A. Reyna
EGEdgar García-Duarte
Edgar García-Duarte
JGJuan Pablo García-Vázquez
Juan Pablo García-Vázquez
RARoberto L. Avitia
Roberto L. Avitia
This article describes a structured clinical dataset collected from 100 adult patients who were previously hospitalized due to moderate-to-severe COVID-19 infection. Data were obtained prospectively at a second-level care hospital in Mexicali, Baja California, Mexico. The dataset includes demographic characteristics, anthropometric measurements, traditional cardiovascular risk factors, general blood test, Questionnaire-derived variables, 12-lead electrocardiographic (ECG) parameters, signal-averaged electrocardiogram (SAECG) measurements, and heart rate variability (HRV) metrics. Questionnaire-derived variables include medical history, cardiovascular risk factors, medication use, lifestyle-related factors, and COVID-19 vaccination information. Laboratory variables include metabolic, renal, lipid, electrolyte, and hematological parameters obtained from routine clinical blood analyses. The 12-lead ECG data include cardiac rhythm classification, measurements of wave and interval durations, electrical axis parameters, and precordial voltage amplitudes. SAECG variables are provided as raw numerical measurements, including total QRS duration, low-amplitude signal duration below 40 µV (LAS40), and root mean square voltage of the last 40 ms (RMS40), together with a variable indicating the presence or absence of ventricular late potentials. HRV parameters are available as continuous time-domain and frequency-domain values, allowing future researchers to apply different clinical thresholds or computational approaches. The dataset is organized into multiple structured Comma-Separated Values (CSV) files distributed across dedicated subdirectories within the Mendeley Data repository. The repository also includes supporting PDF documentation, such as the ethics approval document containing the protocol number, the questionnaire applied during data collection, and the informed consent form. An overview of each variable is provided, and only anonymized patient identifiers are included; no personally identifiable information is contained in the dataset. These data may support future exploratory studies on cardiovascular alterations in post-COVID populations and machine learning applications. The structured format is intended to facilitate secondary data analyses, such as correlational studies and the identification of associations between clinical and electrocardiographic variables.