Blanca Alicia García Grajeda

Dr. Blanca Alicia García Grajeda


Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 June 2017 in RSC Advances
Verified
Journal Article
Open access
PDF file
BGBlanca Alicia García Grajeda
Blanca Alicia García Grajeda
SASamuel G. Soto Acosta
Samuel G. Soto Acosta
Sergio Andres AguilaSergio Andres Aguila
Sergio Andres Aguila
HGHéctor Peinado Guevara
Héctor Peinado Guevara
MDMarta Elena Díaz-García
Marta Elena Díaz-García
José de Jesús Campos-GaxiolaJosé de Jesús Campos-Gaxiola
José de Jesús Campos-Gaxiola
In this paper we describe a simple colorimetric method for the sensitive and selective detection of Ba 2+ ions, using 11-mercaptoundecylphosphonic acid functionalized gold nanoparticles (AuNPs–MPA) in aqueous solution.

5 June 2017 in CrystEngComm
Verified
Journal Article
Closed access
PDF file
José de Jesús Campos-GaxiolaJosé de Jesús Campos-Gaxiola
José de Jesús Campos-Gaxiola
BGBlanca Alicia García Grajeda
Blanca Alicia García Grajeda
IHIrán F. Hernández-Ahuactzi
Irán F. Hernández-Ahuactzi
JGJorge Antonio Guerrero-Álvarez
Jorge Antonio Guerrero-Álvarez
HHHerbert Höpfl
Herbert Höpfl
AEAdriana Cruz Enríquez
Adriana Cruz Enríquez
3- and 4-pyridineboronic acids have been combined with trimesic and pyromellitic acids to give three molecular complexes of compositions [(3PBAH+)(H2TMA−)] (1), [(3PBAH+)2(H2PMA2−)] (2), and [(4PBAH+)2(H2PMA2−)]·2H2O (3) (3PBA = 3-pyridineboronic acid, 4PBA = 4-pyridineboronic acid, H3TMA = trimesic acid, H4PMA = pyromellitic acid). The products have been characterized by elemental analysis, infrared spectroscopy, single-crystal X-ray diffraction analysis and luminescence spectroscopy. The structural analysis revealed that the hydrogen bonding interactions of the resulting 2D and 3D assemblies involve at least one of the following charge-assisted synthons: –B(OH)2⋯−OOCR, RCOOH⋯−OOCR or PyN+–H⋯−OOCR. The dimensions are enhanced by additional hydrogen bonds as well as π–π stacking interactions, which include B⋯π interactions in two crystal structures. Intermolecular close contacts have also been examined by Hirshfeld surface analysis, which by means of the associated 2D fingerprint plots enabled similarities and differences in the crystal structures to be revealed. Solid-state photoluminescence spectroscopy of compounds 1–3 revealed that variations of the π–π stacking in the molecular aggregates induced changes in the emission behavior.

1 December 2021 in Advanced Powder Technology
Verified
Journal Article
Closed access
MAM.A. Avila-Rubio
M.A. Avila-Rubio
Caleb CarreñoCaleb Carreño
Caleb Carreño
Jose Martin Herrera-RamirezJose Martin Herrera-Ramirez
Jose Martin Herrera-Ramirez
BGBlanca Alicia García Grajeda
Blanca Alicia García Grajeda
FPF.A. Pérez-González
F.A. Pérez-González
Jesus Baldenebro-LopezJesus Baldenebro-Lopez
Jesus Baldenebro-Lopez

6 May 2024 in Polymers
Verified
Journal Article
Open access
PDF file
ABA. Bórquez-Mendivil
A. Bórquez-Mendivil
CBCarlos Barrios
Carlos Barrios
RNRosa Elba Núñez-Jaquez
Rosa Elba Núñez-Jaquez
AHAbel Hurtado-Macias
Abel Hurtado-Macias
Jesus Eduardo Leal-PerezJesus Eduardo Leal-Perez
Jesus Eduardo Leal-Perez
Jorge Almaral-SánchezJorge Almaral-Sánchez
Jorge Almaral-Sánchez
A new, sustainable polypropylene terephthalate (PPT) coating was synthesized from recycled polyethylene terephthalate (PET) and applied onto a hydraulic concrete substrate to improve its durability. For the first step, PET bottle wastes were ground and depolymerized by glycolysis using propylene glycol (PG) in a vessel-type reactor (20–180 °C) to synthesize bis(2-hydroxypropyl)-terephthalate (BHPT), which was applied as a coating to one to three layers of hydraulic concrete substrate using the brushing technique and polymerized (150 °C for 15 h) to obtain PPT. PET, BHPT, and PPT were characterized by FT-IR, PET, and PPT using TGA, and the PPT coatings by SEM (thickness), ASTM-D3359-17 (adhesion), and water contact angle (wettability). The durability of hydraulic concrete coated with PPT was studied using resist chloride ion penetration (ASTM-C1202-17), carbonation depth at 28 days (RILEM-CPC-18), and the absorption water ratio (ASTM-C1585-20). The results demonstrated that the BHPT and PPT were synthetized (FT-IR), and PPT had a similar thermal behavior to PET (TGA); the PPT coatings had good adhesion to the substrate, with thicknesses of micrometric units. PPT coatings presented hydrophilic hydrophilic behavior like PET coatings, and the durability of hydraulic concrete coated with PPT (2–3 layers) improved (migration of chloride ions decreased, carbonation depth was negligible, and the absorption water ratio decreased).

18 January 2025 in Journal of Materials Research and Technology
Verified
Journal Article
Open access
ABAdrián Bórquez-Mendivil
Adrián Bórquez-Mendivil
Jorge Almaral-SánchezJorge Almaral-Sánchez
Jorge Almaral-Sánchez
Jesus Eduardo Leal-PerezJesus Eduardo Leal-Perez
Jesus Eduardo Leal-Perez
CMCesar Modesto
Cesar Modesto
JFJ. Flores-Valenzuela
J. Flores-Valenzuela
AHAbel Hurtado-Macias
Abel Hurtado-Macias

3 June 2018 in Inorganic and Nano-Metal Chemistry
Verified
Journal Article
Closed access
BGBlanca Alicia García Grajeda
Blanca Alicia García Grajeda
Sergio Andres AguilaSergio Andres Aguila
Sergio Andres Aguila
HGHéctor Peinado Guevara
Héctor Peinado Guevara
EREdgar Alonso Reynoso
Edgar Alonso Reynoso
AOAdrián Ochoa-Terán
Adrián Ochoa-Terán
José de Jesús Campos-GaxiolaJosé de Jesús Campos-Gaxiola
José de Jesús Campos-Gaxiola
A facile colorimetric method for rapid determination of Cr(III) ions was developed using 11-mercaptoundecylphosphonic acid modified gold nanoparticles (AuNPs-MPA) in aqueous medium. The reaction of AuNPs-MPA + Cr(III) ions were were characterized by FTIR and Uv-Vis spectroscopy. The presence of Cr(III) easily induced aggregation of AuNPs-MPA, resulting in the color change from pink to blue. This method exhibited excellent selectivity toward Cr(III) compared to other metal cations. Optimal detection of Cr(III) was found in a pH range from 4 to 9, the detection time within 8 min. In addition, the developed effective probe has been successfully applied to detect Cr(III) water samples.