Wei Xia

Dr. Wei Xia


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 July 2023 in Photonics
Verified
Journal Article
Open access
PDF file
DGDongmei Guo
Dongmei Guo
ZXZhanwu Xie
Zhanwu Xie
QYQin Yang
Qin Yang
WXWei Xia
Wei Xia
Yanguang YuYanguang Yu
Yanguang Yu
MWMing Wang
Ming Wang
In this study, a multiple-dimensional displacement measurement technology is demonstrated by using self-mixing interferometry (SMI) cooperating with a frequency division multiplexing (FDM) technique. The proposed SMI configuration with a single laser generates three modulated light beams with different carrier frequencies. Each beam is incident on a planar grating with its own auto-collimation diffraction angle. The diffracted beams return to the laser cavity and then self-mixing interference occurs. An algorithm based on FDM is developed for multiple-dimensional displacement reconstruction from a single SMI signal. Experiments are conducted to verify the proposed approach. This paper shows an attractive sensing system for multiple-dimensional displacement featuring compact configuration, high resolution and better immunity to environmental disturbances.

25 January 2024 in IEEE Photonics Journal
Verified
Journal Article
Open access
WWWenxiu Wang
Wenxiu Wang
WZWenjian Zhang
Wenjian Zhang
HHHui Hao
Hui Hao
ZXZhanwu Xie
Zhanwu Xie
LLLiya Liu
Liya Liu
HYHaitao Yan
Haitao Yan
The extra-interfacial manifestations induced by the waveguide resonance properties of monolayer colloidal crystals (MCCs) have been well discovered by symmetrically probing their reflectance spectra. To clearly analyze the origin of the resonance peaks in the spectra obtained by reflection probing, experimental and calculated values were compared and the results for monolayers with different arrangement structures were compared. The different contributions to the resonance modes by different light bands entering the MCC were elucidated. In addition, the experimental results visualize that changing the incident angle, lattice and polarization can effectively modulate the wavelength position and intensity of the characteristic peaks induced by the resonance of the monolayer waveguide.

21 February 2025 in Photonics
Verified
Journal Article
Open access
PDF file
WXWei Xia
Wei Xia
JYJingyu Yu
Jingyu Yu
SSSunan Shao
Sunan Shao
ZQZhengyu Qian
Zhengyu Qian
HHHui Hao
Hui Hao
DGDongmei Guo
Dongmei Guo
This paper studied a multi-channel self-mixing interferometric vibration measurement system based on a vertical-cavity surface-emitting laser array. A 1 × 8 laser array was utilized to irradiate multiple positions of a vibrating target to establish independent measurement channels. The reflected light beams, carrying the vibration information of each position, were redirected back into the laser and coherently mixed with the original optical field, generating the self-mixing interference. The interferometric signals were measured by monitoring the junction voltage variations across the terminals of the VCSEL array. A denoising filtering method based on the variational mode decomposition with Hausdorff distance was proposed to improve the signal-to-noise ratio. Furthermore, the vibration waveforms of different positions were reconstructed using the Hilbert transform-based orthogonal phase demodulation technology. Both simulations on synthetic signals and experiments with real datasets were conducted to validate the feasibility and stability of the proposed method. Due to the array detection configuration, the system boasted a simple and compact structure, low power consumption, and easy extensibility, laying the groundwork for high accuracy and multi-dimensional vibration detection in industrial applications.

15 July 2019 in Sensor Review
Verified
Journal Article
Closed access
WXWei Xia
Wei Xia
LKLingwen Kong
Lingwen Kong
JZJiahuan Zhang
Jiahuan Zhang
HHHui Hao
Hui Hao
Yiping WangYiping Wang
Yiping Wang
DGDongmei Guo
Dongmei Guo
Purpose: The purpose of this study aims to modify a self-mixing laser mouse as an extremely cost-effective displacement sensor to measure the mechanical oscillation of a commercial shaker and a nano-positioning stage. Design/methodology/approach: This kind of laser mouse, mostly consisting of a pair of vertical cavity surface emitting lasers, two photodiodes and an integrated signal processing unit, is capable of directly giving the x-axis and y-axis components of the measured vibrating displacement. Based on the laser self-mixing interference, the velocity of the object is coded into the Doppler frequency shift of the feedback light, which allows accurate determination of the vibration of the object. Findings: A commercial shaker has been used to provide standard harmonic oscillation to test the displacement sensor. Within a vibrating frequency range of 110 Hz, the experimental results show that the micrometer scale resolution has been achieved at the velocity of up to 2 m/s, which is much improved compared with the image-based optical mouse. Furthermore, the measurements of the two dimensional displacement of a nano-positioning stage are performed as well. The minimum measurable velocity limit for this sensor has been discussed in detail, and the relative measurement error can be greatly reduced by appropriate selection of the modulation frequency of the triangular injection current. Originality/value: These results demonstrate the feasibility of this device for the industrial vibration sensing applications.