A study of the functioning of reed switches under the influence of a magnetic field created by a current in a conductor in a transient mode with the presence of an aperiodic component has been carried out. A well-known method for determining current using reed switches was implemented. At the same time, it was determined that the originally formulated method did not give the required result within the limits of errors. This is most likely due to the peculiarities of the mechanism of movement of the reed switch contacts. Alternatively, the measurements were taken to take the return currents instead of the pick-up currents and the time between the return times. They are more stable. Simulation is performed, experimental determination of the value of surge current by measuring time is carried out. The main element of the created installation was the power transformer coil with low active and high inductive resistance. As part of the study, the reed switches were placed in a magnetic field with an aperiodic component, as in the transient mode. This study will show the applicability of reed switches for the construction of relay protection devices that will not need current transformers to obtain information about the primary current in the conductor. In the course of the research, it was found that the error in determining the magnitude of current was no more than 10 %. Using microprocessors, it is possible to build relay protection devices with a speed of up to 20 ms. This result makes it possible to build new devices. Since in the well-known developments, it was only said about determining the magnitude of current in a steady state. When building relay protection devices on reed switches, without using current transformers, it will be possible to build backup protections that duplicate not only the devices themselves, but also the primary measuring transformers with other sensitive elements. This will improve the reliability of the power supply.
From the uncontrolled proliferation of invasive plants, several challenges for the environment arise. Invasive wetland grasses biomass can be collected for biofuel production, thus offering a sustainable solution for invasive plants’ management and contributing to the renewable energy sector. The straw-like shoot biomass of common reed (Phragmites australis), widespread across temperate and tropical zones, has been examined to assess its potential use for energy purposes. We seek to determine the fuel-energy characteristics of common reed biomass, which are necessary for converting it into energy through combustion. A comprehensive analysis was conducted to determine the physical and chemical properties of biomass according to the ISO standards for solid biofuels. These properties included calorific values, moisture, ash and volatile matter contents, and contents of C, H, N, and major and minor elements, as well as ash melting behaviour. The measured values were also compared to standard limits for different classes of densified biofuels. Based on the results, the net calorific value (15.33 MJ/kg ar) and other parameters met the requirements for the class A quality of non-woody briquettes and pellets. The only parameters which exceeded the class A limits were ash content (7.1% d.b.) and Cl content (0.16% d.b.). The findings of this study are important for the potential utilisation of common reed biomass for bioenergy as a step towards contribution to the Sustainable Development Goals.
The design features of high-power ore furnaces are the transformer’s secondary winding made of 4–8 isolated splits and a busbar assembly made of the same number of paired bifilar bus tubes, spaced 20–40 mm apart. Only an arc fault (AF) can occur between paired bus tubes in such an assembly, during which the assembly with currents of 35–150 kA can be completely destructed. To protect against AFs, these bus tubes are wrapped in several layers of gluey fiberglass cloth. However, such cloth is abraded under the impact of airborne abrasive dust particles during furnace operation, and coal dust in the air creates the conditions for an AF. A new current protection with a magnetic current transformer (MCT), which prevents busbar assembly destruction, is suggested. Its design is based on the analysis of the distribution of busbar assembly magnetic fields. The choice of MCT position is justified, and parameters of its windings are determined; MCT construction and fastening are described, and a technique for reliable MCT output signal transmission under strong magnetic fields and with a specified protection threshold is suggested. These protections are currently the simplest and cheapest tool for preventing the complete destruction of an expensive busbar assembly in events of AFs during it.
When operating solar–wind power plants (SWPPs) located in populated areas, cases of premature failure of expensive batteries and other power equipment often occur. The purpose of this study is to develop a wireless data acquisition system (DAS) for the operation of an SWPP with a feedback function to prevent material damage from the failure of power equipment and to increase the efficiency of natural energy use. The principles of constructing a DAS, free from some of the disadvantages of analogues, are described in this paper. Intelligent wireless current and voltage sensors and a device for receiving and recording data with an additional feedback function have been developed, providing real-time feedback when the measured parameters go outside the norm. Measurement data are displayed on the laptop screen and alphanumeric display and stored on the hard drive along with timestamps and current event messages. An example of using a reverse communication channel to implement the functions of backup battery protection and to switch SWPP loads is described. The principles and methods proposed in this article are suitable for constructing systems for remote measurements of any physical quantities; therefore, the scope of application of the described system can be significantly expanded.
An IoT-based technique is suggested for detecting single-phase earth faults (SEFs) in 6–35 kV cable networks with an isolated neutral. Unlike existing methods based on measuring zero-sequence currents with traditional current transformers, the suggested technique uses a passive magnetically controlled contact (reed switch) placed in the magnetic field of a cable. This enables recording fault currents of 0.5–2.0 A without external power supply and ensures galvanic isolation. The novelty of this technique is the combination of a reed switch current sensor with an IoT platform: instantaneous values of current are measured by the duration of the closed state of the contacts, then the data are transmitted via a radio channel (LoRa 433 MHz, LoRaWAN, or NB-IoT) to a cloud-based SCADA/EMS system for remote monitoring. The amplitude of the current is calculated from the pickup and resetting currents, as well as the duration of the closed state of the contacts; no high-frequency ADC is required. During experimental tests of a prototype with a KEM-5 reed switch and a TZL-10 current transformer, the difference between the calculated and actual protection operation current was no more than 10–5%. Oscillograms confirmed the correct operation of the device when starting, under load, and during an artificial SEF with a current of 1.6 A. The device response time is a fraction of the industrial frequency period, which significantly reduces the emergency mode duration. The suggested system enables decreasing the system average interruption duration index (SAIDI) and the system average interruption frequency index (SAIFI) by selectively disconnecting a damaged section and preventing cascading faults. The use of two independent channels (current transformer and reed switch) increases the reliability of SEF detection and reduces the risk of false operation. Thus, the developed IoT-based technique improves the reliability, safety, and cost-effectiveness of cable network operation.