When an induction motor is running at stable speed and low slip, the fault signal of the induction motor’s broken bar faults are easily submerged by the power frequency (50 Hz) signal. Thus, it is difficult to extract fault characteristics. The left-side harmonic component representing the fault characteristics can be distinguished from power frequency owing to V-shaped trajectory of the fault component in time-frequency (t-f) domain during motor startup. This article proposed a scheme to detect broken bar faults and discriminate the severity of faults under starting conditions. In this scheme, successive variable mode decomposition (SVMD) is applied to analyze the stator starting current to extract the fault component, and the signal reconstruction is proposed to maximize the energy of the fault component. Then, the quadratic regression curve method of instantaneous frequency square value of the fault component is utilized to discriminate whether the fault occurs. In addition, according to the feature that the energy of the fault component increases with the fault severity, the energy of the right part of the fault component is proposed to detect the severity of the fault. In this paper, experiments are carried out based on a 5.5 kW three-pole induction motor. The results show that the scheme proposed in this paper can diagnose the broken bar faults and determine the severity of the fault.
Rolling bearings are key components that support the rotation of motor shafts, operating with a quite high failure rate among all the motor components. Early bearing fault diagnosis has great significance to the operation security of motors. The main contribution of this paper is to illustrate Gaussian white noise in bearing vibration signals seriously masks the weak fault characteristics in the diagnosis based on the Teager–Kaiser energy operator envelope, and to propose improved TKEO taking both accuracy and calculation speed into account. Improved TKEO can attenuate noise in consideration of computational efficiency while preserving information about the possible fault. The proposed method can be characterized as follows: a series of band-pass filters were set up to extract several component signals from the original vibration signals; then a denoised target signal including fault information was reconstructed by weighted summation of these component signals; finally, the Fourier spectrum of TKEO energy of the resulting target signal was used for bearing fault diagnosis. The improved TKEO was applied to a vibration signal dataset of run-to-failure rolling bearings and compared with two advanced diagnosis methods. The experimental results verify the effectiveness and superiority of the proposed method in early bearing fault detection.
Factors such as insufficient heat dissipation and excessively high temperature can easily lead to demagnetization of the PMs in permanent-magnet (PM) motors. As a result, the magnetic field distribution of the motor will not be uniform, producing fault harmonics and lowering the operational performance of the motor. An essential stage in the diagnosis of faults and the monitoring of motor condition is the establishment of an accurate model of motors with demagnetization faults. In this paper, demagnetization faults are modeled by changing the Fourier coefficients in the Fourier expansion of the magnetization of PMs. This model can be used to determine the motor performance under various types of demagnetization, including radial air gap flux density, back electromotive force (EMF), and torque. On this basis, the corresponding relationship between the demagnetization degree and the fault signature is established, to provide a theoretical foundation for the subsequent demagnetization fault diagnosis. The finite element analysis (FEA) verifies the effectiveness and superiority of the proposed analytical model. The modeling method proposed in this paper can be applied to PM motors with PMs having different magnetization directions and shapes because it is based on the demagnetization region of PMs.
Since permanent magnets and rotors are core components of electric vehicle drive motors, accurate diagnosis of demagnetization and eccentricity faults is crucial for ensuring the safe operation of electric vehicles. Currently, intelligent diagnostic methods based on three-phase current signals have been widely adopted due to their advantages of easy acquisition, low cost, and non-invasiveness. However, in practical applications, the fault characteristics in current signals are relatively weak, leading to diagnostic performance that falls short of expected standards. To address this issue and improve diagnostic accuracy, this paper proposes a novel diagnostic method. First, branch current is utilized as the data source for diagnosis to enhance the fault characteristics of the diagnostic signal. Next, a dual-modal feature extraction module is constructed, employing Variational Mode Decomposition (VMD) and Fast Fourier Transform (FFT) to concatenate the input branch current along the feature dimension in both the time and frequency domains, achieving nonlinear coupling of time–frequency features. Finally, to further improve diagnostic accuracy, a cascaded convolutional neural network based on dilated convolutional layers and multi-scale convolutional layers is designed as the diagnostic model. Experimental results show that the method proposed in this paper achieves a diagnostic accuracy of 98.6%, with a misjudgment rate of only about 2% and no overlapping feature results. Compared with existing methods, the method proposed in this paper can extract higher-quality fault features, has better diagnostic accuracy, a lower misjudgment rate, and more excellent feature separation ability, demonstrating great potential in intelligent fault diagnosis and maintenance of electric vehicles.
A hybrid heat-pipe cooling structure for the permanent magnet synchronous motor for electric vehicles was analyzed in this paper to effectively equalize the axial temperature rise and reduce the average temperature of each heat-generating component in the motor. A temperature field calculation method for the hybrid heat-pipe cooling permanent magnet synchronous motor based on an equivalent thermal network method was proposed in this paper to save computing resources in temperature field analyses for hybrid heat-pipe cooling motors. The results were verified against the simulation results of the computational fluid dynamics method under three common operating conditions for electric vehicles. The error was proven to be within 5%. The calculation time of the proposed method was compared with the computational fluid dynamics method, which demonstrated that the calculation time of the proposed method was within 194 s.
This paper presents a new position sensorless control strategy for a brushless DC motor (BLDCM) driven by a four-switch three-phase inverter (FSTPI). This strategy introduces a flux-linkage function, which changes obviously at the time of the extremum jump. In the proposed strategy, the extremum jump edge determines the six commutation points needed for motor commutation. Then the high-precision and reliable commutation of the BLDCM is realized. This strategy can be used on BLDCM driven by FSTPI. Compared with other position sensorless control methods for BLDCM driven by FSTPI, the proposed method does not need to set a threshold value to detect the commutation point. It can obtain six commutation points required for motor commutation without interpolation. This avoids commutation errors caused by threshold value setting and interpolation. In addition, this strategy adopts a three-phase current control method for BLDCM driven by FSTPI. It can effectively restrain the current distortion of the capacitor middle point connection phase. And the terminal voltage is calculated. It can avoid the error caused by hardware sampling and improve the accuracy of the position sensorless control strategy. The experimental results verify the correctness of the theory and the effectiveness of the method.