Kulyash Alimova

Dr. Kulyash Alimova

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 April 2021 in Water
Verified
Journal Article
Open access
PDF file
Natalya SalikovaNatalya Salikova
Natalya Salikova
Javier Rodrigo-IlarriJavier Rodrigo-Ilarri
Javier Rodrigo-Ilarri
KAKulyash Alimova
Kulyash Alimova
María-Elena Rodrigo-ClaveroMaría-Elena Rodrigo-Clavero
María-Elena Rodrigo-Clavero
For the first time in scientific literature, this work addresses the current situation of the Ishim River water quality in the Akmola Region (Northern Kazakhstan). This work uses environmental monitoring techniques to analyze the current state of surface waters in the river. The content of main ions, biogenic and inorganic ions, heavy metals, organic impurities in seasonal and annual dynamics have been studied. Results show that, despite the tightening of requirements for wastewater discharge into the Ishim River basin, a number of water quality indicators did not fulfill the regulatory requirements for surface water bodies during 2013–2019. It has been identified that the greatest pollution in the Ishim River is brought by enterprises of the Karaganda-Temirtau technogenic region, located in the upper reaches of the river. Future water quality monitoring is needed and should include increasing the number of sampling locations and the sampling frequency in order to characterize the spatial and temporal variability of hydrochemical parameters and allow a comprehensive monitoring of legally fixed water quality parameters/indicators.

11 May 2024 in Water
Verified
Journal Article
Open access
PDF file
Natalya SalikovaNatalya Salikova
Natalya Salikova
AKAlmagul Kerimkulova
Almagul Kerimkulova
Javier Rodrigo-IlarriJavier Rodrigo-Ilarri
Javier Rodrigo-Ilarri
KAKulyash Alimova
Kulyash Alimova
María-Elena Rodrigo-ClaveroMaría-Elena Rodrigo-Clavero
María-Elena Rodrigo-Clavero
ГКГульжанат Капбасова
Гульжанат Капбасова
This study investigates the presence of microplastics in tap drinking water and evaluates the efficacy of various sorbents for their removal in the context of Kazakhstan’s water treatment system. Water samples taken in the cities of Kokshetau and Krasny Yar (Akmola region) were analyzed. Microplastics were detected in all samples, with concentrations ranging from 2.0 × 10−2 to 6.0 × 10−2 particles/dm3, predominantly in fiber form (74.1%). Outdated technologies and non-compliance with treatment regimens contribute to poor water quality, including high turbidity (87% of samples), color deviations (40% of samples), and acidity issues (20% of samples). To address these challenges, the study examined the sorption efficiency of different sorbents, with results indicating high retention rates (82.7–97.8%) for microplastic particles. Notably, aliphatic structures like PE and PP exhibited higher retention than PET. Among the sorbents tested, the synthesized carbon sorption material (CSM) demonstrated the highest efficiency in both microplastic retention and improvement in water quality parameters, making it a promising option for water treatment facilities and household filters.

1 January 2026 in Water
Verified
Journal Article
Open access
PDF file
María-Elena Rodrigo-ClaveroMaría-Elena Rodrigo-Clavero
María-Elena Rodrigo-Clavero
Javier Rodrigo-IlarriJavier Rodrigo-Ilarri
Javier Rodrigo-Ilarri
KAKulyash Alimova
Kulyash Alimova
Natalya SalikovaNatalya Salikova
Natalya Salikova
LMLyudmila Makeyeva
Lyudmila Makeyeva
МБМейірман Бердали
Мейірман Бердали
Microplastics are increasingly recognized as contaminants of emerging concern in wastewater systems, where treatment plants act both as sinks and as point sources. However, Central Asian wastewater infrastructures are under-represented in the literature, and global syntheses are hindered by strong methodological heterogeneity (sampling regimes, size cut-offs, QA/QC). This PRISMA-guided critical review compiles and harmonizes data from 63 WWTP studies worldwide (402 matrix-stage observations), including the few available case studies from Kazakhstan and neighboring countries, to benchmark Central Asian plants against a global envelope and identify methodological and infrastructure gaps. Globally, influent concentrations cluster around a median ≈65 particles/L, while final/tertiary effluents show a median ≈2.2 particles/L. Median removal efficiency is 85.5% for secondary and 95.0% for tertiary/advanced trains, with ≈103–105 particles/kg DW typically retained in sludge. Across influent, effluent and sludge, fibers and fragments of PE, PP and PET dominate polymer morphology patterns, with similar PET/PE/PP signatures also reported in downstream river water. Central Asian influents fall within global interquartile ranges, but secondary-only facilities tend to yield effluents in the upper half of the global distribution. Overall, the review provides a first integrated, methodologically explicit assessment of WWTP microplastics in Central Asia and underscores the need for protocol harmonization, longitudinal monitoring, and targeted upgrades of polishing steps and sludge management in arid hydrosystems.

27 June 2025 in Buildings
Verified
Journal Article
Open access
PDF file
AGAbiyeva Guldana
Abiyeva Guldana
SNSAYAT NIYETBAY
SAYAT NIYETBAY
AZArman Zhanguzhinov
Arman Zhanguzhinov
GKGulbanu Kassabekova
Gulbanu Kassabekova
DJDilyara Jartayeva
Dilyara Jartayeva
BKBostandyk Khalkhabay
Bostandyk Khalkhabay
The growing demands for sanitary regulations in medical facilities, particularly operating rooms, highlight the importance of ensuring high air quality and minimizing airborne hospital-acquired infections. Improperly designed ventilation systems may lead to contamination of up to 90–95% of patients, especially in light of evolving threats, such as COVID-19. This study focuses on enhancing the energy efficiency and performance of air conditioning and ventilation systems for cleanrooms, where air recirculation is not permissible. A novel energy-efficient direct-flow air treatment scheme is proposed, integrating a heat pump system with adjustable thermal output. A computational fluid dynamics CFD model of a clean operating room was developed to assess the impact of inlet air velocity on aerosol particle removal and airflow stabilization time. The model also considers the effect of personnel movement. The results supported optimized air distribution, reducing microbial contamination risks, with less than 10 CFU/m3, and improved thermal performance. The proposed system was evaluated for energy and cost efficiency compared to conventional setups. Findings can inform the design and operation of cleanroom ventilation in surgical environments and other high-tech applications. This research contributes to improving indoor air quality and reducing infection risks while enhancing sustainability in healthcare infrastructure.

1 June 2026 in Membranes
Verified
Journal Article
Open access
PDF file
FBFazolrahman Bahig
Fazolrahman Bahig
KAKulyash Alimova
Kulyash Alimova
Nikita MartyushevNikita Martyushev
Nikita Martyushev
Boris V MalozyomovBoris V Malozyomov
Boris V Malozyomov
VKVladislav Kukartsev
Vladislav Kukartsev
YTYadviga Aleksandrovna Tyncheko
Yadviga Aleksandrovna Tyncheko
Safe drinking water production from compositionally variable surface sources requires treatment systems that combine effective contaminant removal with stable membrane operation. This study experimentally evaluated a hybrid treatment train consisting of slow sand or zeolite pretreatment followed by NF for surface water representative of South-East Kazakhstan. The results showed that pretreatment reduced turbidity, iron, and organic load before the membrane stage, thereby improving flux stability and decreasing fouling propensity. Among the tested pretreatment options, zeolite provided the most favorable feed conditions and extended stable membrane operation. These findings demonstrate that the practical performance of NF depends not only on membrane properties but also on effective upstream conditioning of the feed stream. Under the tested recovery conditions, the selected operating regime produced permeate of acceptable final quality, confirming that hybrid pretreatment–NF systems are a robust option for drinking-water treatment from challenging surface sources.

15 February 2020 in THE BULLETIN
Verified
Journal Article
Closed access
ZKZhuzbay Kassymbekov
Zhuzbay Kassymbekov
OAO. V. Atamanova
O. V. Atamanova
KAKulyash Alimova
Kulyash Alimova
GKGalymzhan Kassymbekov
Galymzhan Kassymbekov
The design features of the existing design and technology for the protection of downhole pumps of the ECV type from abrasive wear during operation are considered and analyzed. Based on the analysis, a new method for capturing solid impurities on the suction line of a borehole pump of the ECV type using a pressure-vacuum hydrocyclone is proposed. It is specified that at field tests of a prototype of new installation technological process is estimated on the pressure-expense characteristic and technological-operational indicators according to requirements of GOST 6134-81 " pumps dynamic. Test method. " In this case, the flow rate of the base pump on water is determined by means of a turbine water meter mounted on a water-lifting pipe with a valve. The performance of the hydraulic elevator is established by the volumetric method, and the head in front of the valve of the pump pressure pipe using an approximate pressure gauge. It is established that the flow-pressure characteristics of the base submersible pump ECV are provided in full (water flow 60-70 m3/h, head - 110-118 m), overload on the electric motor is not detected (ammeter readings are within the permissible limits-68-71 amperes), the degree of water purification is 95-96%. It is noted that the implementation of a flexible packer device with slots and the presence on the surface of the second minihydrocyclone-thickener significantly improves the functioning of the adopted scheme of water treatment. It turned out that with this technology, the overload of the pump motor is reduced by cooling with water without mechanical impurities.