Detecting respiration in a non-intrusive manner is beneficial not only for convenience but also for cases where the traditional ways cannot be applied. This paper presents a novel simple low-cost system where ambient Wi-Fi signals are acquired by a third-party tool (Nexmon) installed in a Raspberry Pi and is able to detect the respiration time domain waveform of a person. This tool was selected as it uses 80 MHz bandwidth of the Wi-Fi signal and supports the latest implementations that are widely used, such as 802.11ac. A neural network is developed to detect the respiration frequency of the waveform. Generated waves emulating respiration waveforms were used for training, validating, and testing the model. The model can be applied to unseen real measurement data and successfully determine the breathing frequency with a very low average error of 4.7% tested in 20 measurement datasets.
14 January 2008 in IEEE Transactions on Microwave Theory and Techniques
This paper reports a novel voltage and current waveform measurement system suitable for large-signal transistor and power amplifier characterization and optimization. This technique is original in its use of a double six-port (SP) reflectometer as a homodyne vector network analyzer, which is calibrated in magnitude and phase by means of a reference multiharmonic signal generator, to measure the waveforms at the output terminal of the device. An active branch load-pull setup is used to control the source impedance at the fundamental frequency, and the load impedance at the fundamental, second, and third harmonic frequencies. The capability of the proposed SP reflectometer-based configuration is demonstrated experimentally, by measuring the voltage and current waveforms of a GaAs metal-semiconductor field-effect transistor that is biased in class AB and tuned for maximum efficiency. To assess the level of accuracy of the proposed method, the same waveforms were also measured using a microwave-transition-analyzer-based system. A comparison of the results shows that the proposed SP reflectometer setup obtains results accurate enough for power amplifier characterization with lower equipment cost.
This paper presents a deep learning algorithm for channel estimation in 5G New Radio (NR). The classical approach that uses neural networks for channel estimation requires more than one stage to obtain the full channel matrix. First, the channel has to be constructed by the received reference signal, and then, the precision is improved. In contrast, to reduce the computational cost, the proposed neural network method generates the channel matrix from the information captured from a few subcarriers along the slot. This information is extrapolated by applying the Least Square technique only on the Demodulation Reference Signal (DMRS). The received DMRS placed in the grid can be seen as a 2D low-resolution image and it is processed to generate the full channel matrix. To reduce complexity in the hardware implementation, the convolutional neural network (CNN) structure is selected. This solution is analyzed comparing the Mean Square Error (MSE) and the computational cost with other deep learning-based channel estimation, as well as the traditional channel estimation methods. It is demonstrated that the proposed neural network delivers substantial complexity savings and favorable error performance. It reduces the computational cost by an order of magnitude, and it has a maximum error discrepancy of 0.018 at 5 dB compared to Minimum Mean Square Error (MMSE) channel estimation.
20 November 2024 in IEEE Transactions on Microwave Theory and Techniques
A novel dual-band continuous-wave (CW) radar system is proposed. The radar is designed for vital signs detection in terms of breathing rate (BR), heart rate (HR), and radar cardiograph (RCG) waveforms. The system operates at two ISM band frequencies: 2.45 and 5.8 GHz. Two five-port receivers are used as IQ demodulators. A newly developed interference cancellation method is proposed. This new method increases the reliability of heartbeat detection by canceling the interfering respiration signal in terms of its fundamental frequency component. This method is first demonstrated in the frequency domain through signal processing and second implemented in the time domain using hardware. High detection accuracy is demonstrated for several experimental scenarios. The measurement results show that the proposed system detects vital signs effectively with a relative error of less than 5% at distances (between the radar and the measured subject) of up to 2.5 m using the frequency-domain method and 1.5 m using the time-domain method.
Wireless communication infrastructure is a key enabling technology for smart cities. This paper investigates a novel technique to enhance the performance of 5G base stations by addressing the compensation of nonlinear distortions caused by radiofrequency power amplifiers. For this purpose, a sequential digital predistortion approach that uses twin nonlinear two-box structure along with reduced sampling rates in the feedback path is proposed to implement a linearization system. Such a system is shown to have a correction bandwidth that exceeds the bandwidth of the feedback path. This is achieved by synthesizing the predistortion function in two successive characterization iterations. Both characterizations use the same hardware, which has a reduced sampling rate in the feedback path. Hence, the proposed predistorter scheme does not require any additional hardware compared to standard schemes. Moreover, coarse delay alignment is performed while identifying the memory polynomial function in order to further reduce the computational complexity of the proposed system. Experimental results using an inverse Class-F power amplifier demonstrate the ability of the proposed predistorter to achieve a correction bandwidth of 100 MHz with a feedback sampling rate as low as 25 MSa/s.