Ines Tavoletta

Dr. Ines Tavoletta

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
ITInes Tavoletta
Ines Tavoletta
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
LRLuca Pasquale Renzullo
Luca Pasquale Renzullo
GOGiuseppe Oliva
Giuseppe Oliva
DPDomenico Del Prete
Domenico Del Prete
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
An optical–chemical sensor based on two modified plastic optical fibers (POFs) and a molecularly imprinted polymer (MIP) is realized and tested for the detection of 2-furaldehyde (2-FAL). The 2-FAL measurement is a scientific topic of great interest in different application fields, such as human health and life status monitoring in power transformers. The proposed sensor is realized by using two POFs as segmented waveguides (SW) coupled through a micro-trench milled between the fibers and then filled with a specific MIP for the 2-FAL detection. The experimental results show that the developed intensity-based sensor system is highly selective and sensitive to 2-FAL detection in aqueous solutions, with a limit of detection of about 0.04 mg L−1. The proposed sensing approach is simple and low-cost, and it shows performance comparable to that of plasmonic MIP-based sensors present in the literature for 2-FAL detection.

17 July 2024 in Chemosensors
Verified
Journal Article
Open access
PDF file
LRLuca Pasquale Renzullo
Luca Pasquale Renzullo
ITInes Tavoletta
Ines Tavoletta
Giancarla AlbertiGiancarla Alberti
Giancarla Alberti
LZLuigi Zeni
Luigi Zeni
Maria PesaventoMaria Pesavento
Maria Pesavento
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
In this study, a surface plasmon resonance (SPR) sensor based on modified plastic optical fibers (POFs) was combined with a specific molecularly imprinted polymer (MIP), used as a synthetic receptor, for glyphosate (GLY) determination in aqueous solutions. Since GLY is a non-selective herbicide associated with severe environmental and health problems, detecting glyphosate in environmental and biological samples remains challenging. The selective interaction between the MIP layer and GLY is monitored by exploiting the SPR phenomenon at the POF’s gold surface. Experimental results show that in about ten minutes and by dropping microliter volume samples, the presented optical–chemical sensor can quantify up to three orders of magnitude of GLY concentrations, from nanomolar to micromolar, due to a thin MIP layer over the SPR surface. The developed optical–chemical sensor presents a detection limit of about 1 nM and can be used for onsite GLY measurements. Moreover, the experimental analysis demonstrated the high selectivity of the proposed POF-based chemical sensor.

18 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
ITInes Tavoletta
Ines Tavoletta
RORicardo Oliveira
Ricardo Oliveira
Filipa SequeiraFilipa Sequeira
Filipa Sequeira
CNCatarina Cardoso Novo
Catarina Cardoso Novo
LZLuigi Zeni
Luigi Zeni
RNRogerio Nunes Nogueira
Rogerio Nunes Nogueira
Albendazole (ABZ) is a broad-spectrum anthelmintic drug whose residual presence in food and the environment raises public health concerns, requiring rapid and sensitive methods of detection. In this work, a sensitive Fabry–Pérot interferometer (FPI) probe was fabricated by realizing a cavity located at the tip of a single-mode optical fiber core with a molecularly imprinted polymer (MIP) for ABZ detection. The fabrication process involved the development of a photoresist-based micro-hole filled by the specific MIP via thermal polymerization. Interferometric measurements obtained using the proposed sensor system have demonstrated a limit of detection (LOD) of 27 nM, a dynamic concentration range spanning from 27 nM (LOD) to 250 nM, and a linear response at the nanomolar level (27 nM–100 nM). The selectivity test demonstrated no signal when interfering molecules were present, and the application of the sensor for ABZ quantification in a commercial pharmaceutical sample provided good recovery, in accordance with bioanalytical validation standard methods. These results demonstrate the capability of a MIP layer-based FPI probe to provide low-cost and selective optical-sensing strategies, proposing a competitive approach to traditional analytical techniques for ABZ monitoring.

5 April 2026 in Translational Oncology
Verified
Journal Article
Open access
LALuisa Amato
Luisa Amato
ITInes Tavoletta
Ines Tavoletta
Caterina De RosaCaterina De Rosa
Caterina De Rosa
Mimimorena SeggioMimimorena Seggio
Mimimorena Seggio
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
LZLuigi Zeni
Luigi Zeni
Small cell lung cancer (SCLC) is an aggressive neuroendocrine tumor with poor prognosis and limited benefit from immune checkpoint inhibitors (ICIs). Biomarker-driven patient stratification has been hindered by small biopsy samples, high tumor heterogeneity, and the limited predictive value of PD-L1 and tumor mutation burden. Mitochondrial antiviral-signaling protein (MAVS) has emerged as a potential immune activation marker, particularly in patients receiving DNA-damaging therapies. We report a proof-of-concept clinical study evaluating a surface plasmon resonance-plastic optical fiber (SPR‑POF) biosensor functionalized with anti-MAVS antibodies to detect the protein in serum from SCLC patients undergoing chemo-immunotherapy, with or without radiotherapy. The biosensor achieved a limit of detection of 0.13 nM in human diluted serum and demonstrated high selectivity against common serum proteins. In a cohort stratified as best responders (disease control >6 months) and non-responders (progressive disease as best response), MAVS levels measured in responders were on average tenfold higher than in non-responders, consistent with previous preclinical PBMC and western blot data. The SPR‑POF platform demonstrated portability, cost-effectiveness (estimated 5 USD/unit), and operational simplicity, highlighting its potential for point-of-care testing (POCT) applications. Although limited by small patient numbers, these findings support MAVS as a promising predictive biomarker in SCLC, warranting validation in larger prospective studies.

17 November 2025 in Polymers
Verified
Journal Article
Open access
PDF file
ITInes Tavoletta
Ines Tavoletta
Francesco ArcadioFrancesco Arcadio
Francesco Arcadio
LZLuigi Zeni
Luigi Zeni
RORicardo Oliveira
Ricardo Oliveira
RNRogerio Nunes Nogueira
Rogerio Nunes Nogueira
Nunzio CennamoNunzio Cennamo
Nunzio Cennamo
Two low-cost optical–chemical sensors based on plastic optical fibers (POFs) and molecularly imprinted polymers (MIPs) are developed and tested for the detection of 4-chloro-2-methylphenoxyacetic acid (MCPA), a herbicide of great interest in environmental monitoring. The first sensor is based on an optical splitter composed of two modified POFs coupled with an MIP for measuring MCPA. The second type of sensor is based on a surface plasmon resonance (SPR) D-shaped POF platform combined with the same MIP receptor for MCPA. The two proposed polymer-based sensors, exploiting different optical phenomena, were tested using similar equipment, consisting of white light sources and spectrometers. The experimental results show that both MCPA sensors present high selectivity for the target analyte and similar performances in terms of detection limits (LODs) of 3 nM and detection ranges (between 3 nM and 500 nM) by exploiting the MIP’s sites with a similar affinity constant. The polymer-based sensors exhibited better performances than those achieved by the electrochemical technique combined with the same MIP presented in the literature. Then, tests performed on real samples demonstrated good recovery values (between 82% and 116%), assessing the applicability of both sensors in real-world scenarios. Moreover, the POF-MIP splitter sensor configuration can be fabricated without expensive fabrication steps, such as spinning and sputtering processes.