CHAO ZHANG

Mr. CHAO ZHANG


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2025 in Photonics
Verified
Journal Article
Open access
PDF file
BPBao-Rui Peng
Bao-Rui Peng
富申富康 申
富康 申
ZLZi-Yi Luo
Zi-Yi Luo
CZCHAO ZHANG
CHAO ZHANG
YCYung William Sasy Chan
Yung William Sasy Chan
Ping XiangPing Xiang
Ping Xiang
Carbon fiber-reinforced polymer (CFRP) laminates have been widely coated on aged and damaged structures for recovering or enhancing their structural performance. The health conditions of the coated composite structures have been given high attention, as they are critically important for assessing operational safety and residual service life. However, the current problem is the lack of an efficient, long-term, and stable monitoring technique to characterize the structural behavior of coated composite structures in the whole life cycle. For this reason, bare and packaged fiber Bragg grating (FBG) sensors have been specially developed and designed in sensing networks to monitor the structural performance of CFRP-coated composite beams under different loads. Some optical fibers have also been inserted in the CFRP laminates to configure the smart CFRP component. Detailed data interpretation has been conducted to declare the strengthening process and effect. Finite element simulation and simplified theoretical analysis have been conducted to validate the experimental testing results and the deformation profiles of steel beams before and after the CFRP coating has been carefully checked. Results indicate that the proposed FBG sensors and sensing layout can accurately reflect the structural performance of the composite beam structure, and the CFRP coating can share partial loads, which finally leads to the downward shift in the centroidal axis, with a value of about 10 mm. The externally bonded sensors generally show good stability and high sensitivity to the applied load and temperature-induced inner stress variation. The study provides a straightforward instruction for the establishment of a structural health monitoring system for CFRP-coated composite structures in the whole life cycle.

22 July 2024 in Buildings
Verified
Journal Article
Open access
PDF file
CCchen cong
chen cong
CZCHAO ZHANG
CHAO ZHANG
JMJie Ma
Jie Ma
SHShi-Zhong He
Shi-Zhong He
JCJian Chen
Jian Chen
Huaping WangHuaping Wang
Huaping Wang
Carbon fiber-reinforced polymer (CFRP) components were extensively used and current studies mainly refer to CFRP laminates. The dynamic performance of the complicated CFRP antenna beams is yet to be explored. Therefore, a sensor layout based on fiber Bragg gratings (FBGs) in series was designed to measure the dynamic response of the CFRP antenna beam, and various vibration tests (sweep frequency test, simulated long-life vibration test, shock vibration test, functional vibration test, and constant frequency vibration test) were conducted. The time and frequency domain analysis on FBG sensing signals was performed to check the vibration performance and assess the health condition of this novel CFRP structure. The results indicate that strain values reach a maximum of only 300 µε under different test conditions. The antenna beam exhibited clear vibration patterns, with the first four intrinsic frequencies identified at 44, 94.87, 107.1, and 193.45 Hz. It shows that strain distribution and vibration modes of the antenna beam can be characterized from the sensing data, and the dynamic feature can be much more accurately assessed. The FBG sensors attached on the surface of CFRP antenna beam can accurately and stably measure the dynamic response, which validates that the interfaces between optical fiber sensing elements and CFRP material have excellent interfacial bonding characteristics. The novel CFRP antenna beam exhibits the excellent dynamic performance and stability, offering the replacement of traditional steel antenna beams. The study can finally instruct the development of self-sensing CFRP antenna beams assembled with FBGs in series.

3 October 2024 in Symmetry
Verified
Journal Article
Open access
PDF file
CZCHAO ZHANG
CHAO ZHANG
GLGuo-Zhi Li
Guo-Zhi Li
MWMaihemuti Wusiman
Maihemuti Wusiman
GYGe Yan
Ge Yan
CYChang-Lin Yan
Chang-Lin Yan
Huaping WangHuaping Wang
Huaping Wang
Pipes are the main structures serving as the lifeline for oil and gas transportation. However, they are prone to cracks, holes and other damages due to harsh working environments, which can lead to leakage incidents and result in significant economic losses. Therefore, the development of structural health monitoring systems with advanced online diagnostic methods is of great importance for identifying local damages and assessing the safety state of pipe structures. These efforts can guide rapid repairs and ensure the continuous, efficient and cost-effective transportation of oil and gas resources. To address this problem, this paper proposes the development of a pipe monitoring system based on quasi-distributed fiber Bragg grating (FBG) sensing technology. The SSI-COV method is employed to process the sensor responses and extract the modal parameters of the structure. Based on this foundation, an enhanced damage identification index is proposed, which mitigates the effects of support and excitation positions on damage identification. The pipe structure can be regarded as a continuous super-statical beam, and based on its structural symmetry, a unit structure, specifically a stainless-steel pipe with fixed ends, is regarded as the experimental subject. Impact experiments have been conducted to analyze its behavior in both undamaged and damaged states. The research indicates that by using the proposed modal parameter identification method and the ASMDI damage index, ASMDI exhibits peak values at damage locations of the pipe structure. This allows for the identification of structural damage with high accuracy, fast processing efficiency and strong robustness. The study provides an effective and reliable damage diagnosis method, which can contribute to the refinement and visualization of pipe structural health monitoring systems.