Carlos Gilabert Torres

Mr. Carlos Gilabert Torres

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2024 in Batteries
Verified
Journal Article
Open access
PDF file
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
JFJuan Ignacio Fernández-Carrasco
Juan Ignacio Fernández-Carrasco
As residential adoption of renewable energy sources increases, optimizing rooftop photovoltaic systems (RTPVs) with Battery Energy Storage Systems (BESSs) is key for enhancing self-sufficiency and reducing dependence on the grid. This study introduces a novel methodology for sizing Home Energy Management Systems (HEMS), with the objective of minimizing the cost of imported energy while accounting for battery degradation. The battery model integrated nonlinear degradation effects and was evaluated in a real case study, considering different temporal data resolutions and various energy management strategies. For BESS capacities ranging from 1 to 5 kWh, the economic analysis demonstrated cost-effectiveness, with a Net Present Value (NPV) ranging from 54.53 € to 181.40 € and discounted payback periods (DPBs) between 6 and 10 years. The proposed HEMS extended battery lifespan by 22.47% and improved profitability by 21.29% compared to the current HEMS when applied to a 10 kWh BESS. Sensitivity analysis indicated that using a 5 min resolution could reduce NPV by up to 184.68% and increase DPB by up to 43.12% compared to a 60 min resolution for batteries between 1 and 5 kWh. This underscores the critical impact of temporal resolution on BESS sizing and highlights the need to balance accuracy with computational efficiency.

19 August 2025 in Energies
Verified
Journal Article
Open access
PDF file
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
Leocadio HontoriaLeocadio Hontoria
Leocadio Hontoria
JFJuan Ignacio Fernández-Carrasco
Juan Ignacio Fernández-Carrasco
AMAdel Mellit
Adel Mellit
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas
The decarbonization of the energy sector drives the implementation of building-integrated and building-applied photovoltaic (BIPV–BAPV) systems. However, these systems face space and design limitations in urban environments. This study proposes an innovative methodology for the design and sizing of urban photovoltaic systems, considering diverse distributions and introducing metrics that link performance to occupied area. The methodology was applied to a university building in southern Spain, comparing the performance of rooftop photovoltaic (RTPV) and facade-applied photovoltaic (FAPV) systems. FAPV showed a larger useful area, resulting in similar self-sufficiency indices (RTPV: 22%, FAPV: 21%) and a 5% higher total emission reduction compared to the RTPV system. The proposed metrics demonstrate that FAPV outperforms RTPV both in final yield (49 vs. 21 kWh/kWp·m2) and total emission reduction (3.1 vs. 1.3 kgCO2eq/kWp·m2) normalized by installed power and occupied area. These complementary metrics are crucial for evaluating and selecting optimal photovoltaic configurations with varying generation densities and efficiencies, driving urban decarbonization and the creation of Zero Energy Buildings (ZEBs).

9 August 2025 in Batteries
Verified
Journal Article
Open access
PDF file
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas
CRCarlos Andres Ramos-Paja
Carlos Andres Ramos-Paja
Sergio Ignacio Serna-GarcésSergio Ignacio Serna-Garcés
Sergio Ignacio Serna-Garcés
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
Juan AguilarJuan Aguilar
Juan Aguilar
The effective integration of energy storage systems is paramount for the widespread deployment of renewable energy technologies. Selection of a specific storage system is typically dictated by the primary challenge it aims to mitigate, such as intermittency, grid stability, or power quality. The optimization of overall system efficiency and longevity is increasingly achieved through hybrid storage systems that integrate supercapacitors into their designs. This research introduces a novel circuital equivalent for a commercial supercapacitor, optimized for precise simulations within the frequency range of power electronics applications. A key distinction of this circuital equivalent lies in its rigorous foundation: its comprehensive characterization across a broad frequency spectrum, specifically from 0.01 Hz to 300 kHz, employing a commercial frequency response analyzer. This precise circuital representation offers substantial utility in simulation, analysis, and design of high-frequency circuits, particularly for switched-power converter design and control. It enables the anticipation of undesirable phenomena, such as significant voltage ripple and operational instability. This predictive capability is crucial for experimental preparation, facilitating the proactive integration of necessary filters and protective measures within sensing circuits, thereby underscoring its value prior to physical implementation. In addition, the developed circuital equivalent exhibits broad compatibility, allowing seamless implementation within commercial circuit simulators. Finally, the proposed methodology was illustrated with a commercial supercapacitor, but it can be applied to other supercapacitor types or manufacturers.

13 August 2024 in Electronics
Verified
Journal Article
Open access
PDF file
Antonio Cano OrtegaAntonio Cano Ortega
Antonio Cano Ortega
F. Sánchez-SutilF. Sánchez-Sutil
F. Sánchez-Sutil
Jesús C. HernándezJesús C. Hernández
Jesús C. Hernández
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
Carlos R. R BaierCarlos R. R Baier
Carlos R. R Baier
Power quality measurements are essential to monitor, analyse and control the operation of smart grids within power systems. This work aims to develop and calibrate a PQ network analyser. As the penetration of non-linear loads connected to power systems is increasing every day, it is essential to measure power quality. In this sense, a power quality (PQ) analyser is based on the high-speed sampling of electrical signals in single-phase and three-phase electrical installations, which are available in real time for analysis using wireless Wi-Fi (Wireless-Fidelity) networks. The PQAE (Power Quality Analyser Embedded) power quality analyser has met the calibration standards for Class A devices from IEC 61000-4-30, IEC 61000-4-7 and IEC 62586-2. In this paper, a complete guide to the tests included in this standard has been provided. The Fast Fourier Transform (FFT) obtains the harmonic components from the measured signals and the window functions used reduce spectral leakage. The window size depends on the fundamental frequency of, intensity of and changes in the signal. Harmonic measurements from the 2nd to 50th harmonics for each phase of the voltage and each phase and neutral of the current have been performed, using the Fast Fourier transform algorithm with various window functions and their comparisons. PQAE is developed on an open-source platform that allows you to adapt its programming to the measurement needs of the users.

26 March 2026 in Sensors
Verified
Journal Article
Open access
PDF file
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
Sergio Ignacio Serna-GarcésSergio Ignacio Serna-Garcés
Sergio Ignacio Serna-Garcés
CRCarlos Andres Ramos-Paja
Carlos Andres Ramos-Paja
Juan AguilarJuan Aguilar
Juan Aguilar
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas
The characterization of supercapacitors (SCs), particularly electric double-layer capacitors (EDLCs), is useful for the design of energy management systems. This article presents a five-parameter dynamic model based on electrochemical impedance spectroscopy (EIS) data. Unlike conventional fixed-parameter models, this study explores an approach that accounts for voltage dependence. The model was evaluated using four commercial 58-farad SCs over a frequency range of 10 mHz to 300 kHz and at voltages ranging from 6.25% to 93.75% of the nominal value. The results show that the parameters vary with the state of charge; for example, the effective capacitance increased by up to 24% when moving from 6.25% to 50% of the nominal voltage. The model, fitted using nonlinear optimization algorithms, has a mean square percentage error (MSPE) of less than 3%. This approach estimates the dynamic behavior of the SCs, facilitating the simulation and tuning of management and protection strategies.

26 June 2024
Verified
Conference Paper
Closed access
PVPedro Gómez Vidal
Pedro Gómez Vidal
JFJuan I. Fernández-Carrasco
Juan I. Fernández-Carrasco
FRF.J. Muñoz Rodríguez
F.J. Muñoz Rodríguez
Gabino Jiménez-CastilloGabino Jiménez-Castillo
Gabino Jiménez-Castillo
Carlos Gilabert TorresCarlos Gilabert Torres
Carlos Gilabert Torres
Catalina Rus-CasasCatalina Rus-Casas
Catalina Rus-Casas
In recent years, bachelor's degrees have undergone thorough evaluations to ensure the quality and relevance of university education. University quality agencies oversee accreditation processes involving different stakeholders, ensuring transparency and international recognition. These procedures enhance degree programs by encouraging analysis and collaboration in content implementation. In the engineering field, the design of educational spaces focused on integrating executed projects may be crucial. This paper presents the experience of using photovoltaic installations as engineering projects to develop specific competencies and promote key skills in industrial project management. Transforming learning spaces with real projects proves essential for more comprehensive and effective engineering education.