Deokmin Jeon

Mr. Deokmin Jeon

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
DSDaewoon Seong
Daewoon Seong
DJDeokmin Jeon
Deokmin Jeon
RWRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
KPKibeom Park
Kibeom Park
HKHyeree Kim
Hyeree Kim
JKJeehyun Kim
Jeehyun Kim
The primary optimization of the imaging speed of optical coherence tomography (OCT) has been keenly studied. In order to overcome the major speed limitation of spectral-domain OCT (SD-OCT), we developed an ultrahigh-speed SD-OCT system, with an A-scan rate of up to 1 MHz, using the method of space–time-division multiplexing (STDM). Multicameras comprising a single spectrometer were implemented in the developed ultrahigh-speed STDM method to eliminate the dead time of operation, whereas STDM was simultaneously employed to enable wide-range scanning measurements at a high speed. By successfully integrating the developed STDM method with GPU parallel processing, 8 vol/s for an image range of $250\times 250\times2048$ pixels ( $9\times 4.5\times 5$ mm) was achieved, with an adjustable volume rate according to the required scanning speed and range. The examined STDM-OCT results of the customized optical thin film confirmed its feasibility for various fields that require rapid and wide-field scanning.

20 December 2019 in Sensors
Verified
Journal Article
Open access
PDF file
DSDaewoon Seong
Daewoon Seong
JKJaehwan Kwon
Jaehwan Kwon
DJDeokmin Jeon
Deokmin Jeon
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
JLJaeyul Lee
Jaeyul Lee
JKJeehyun Kim
Jeehyun Kim
Non-invasive characterization of micro-vibrations in the tympanic membrane (TM) excited by external sound waves is considered as a promising and essential diagnosis in modern otolaryngology. To verify the possibility of measuring and discriminating the vibrating pattern of TM, here we describe a micro-vibration measurement method of latex membrane resembling the TM. The measurements are obtained with an externally generated audio stimuli of 2.0, 2.2, 2.8, 3.1 and 3.2 kHz, and their respective vibrations based tomographic, volumetric and quantitative evaluations were acquired using optical Doppler tomography (ODT). The micro oscillations and structural changes which occurred due to diverse frequencies are measured with sufficient accuracy using a highly sensitive ODT system implied phase subtraction method. The obtained results demonstrated the capability of measuring and analyzing the complex varying micro-vibration of the membrane according to implied sound frequency.

7 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
SHSangyeob Han
Sangyeob Han
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
DJDeokmin Jeon
Deokmin Jeon
YHYoungmin Han
Youngmin Han
JLJaeyul Lee
Jaeyul Lee
JKJeehyun Kim
Jeehyun Kim
Depth-visualizing sensitivity can be degraded due to imperfect optical alignment and non-equidistant distribution of optical signals in the pixel array, which requires a measurement of the re-sampling process. To enhance this depth-visualizing sensitivity, reference and sample arm-channeled spectra corresponding to different depths using mirrors were obtained to calibrate the spectrum sampling prior to Fourier transformation. During the process, eight interferogram patterns corresponding to point spread function (PSF) signals at eight optical path length differences were acquired. To calibrate the spectrum, generated intensity points of the original interferogram were re-indexed towards a maximum intensity range, and these interferogram re-indexing points were employed to generate a new lookup table. The entire software-based process consists of eight consecutive steps. Experimental results revealed that the proposed method can achieve images with a high depth-visualizing sensitivity. Furthermore, the results validate the proposed method as a rapidly performable spectral calibration technique, and the real-time images acquired using our technique confirm the simplicity and applicability of the method to existing optical coherence tomography (OCT) systems. The sensitivity roll-off prior to the spectral calibration was measured as 28 dB and it was halved after the calibration process.

22 November 2013 in Nano Letters
Verified
Journal Article
Closed access
XLXin Liu
Xin Liu
Changho LeeChangho Lee
Changho Lee
Wing-Cheung LawWing-Cheung Law
Wing-Cheung Law
DZDewei Zhu
Dewei Zhu
MLMaixian Liu
Maixian Liu
MSMak T Swihart
Mak T Swihart

1 December 2018 in Infrared Physics & Technology
Verified
Journal Article
Closed access
DJDeokmin Jeon
Deokmin Jeon
Naresh Kumar RavichandranNaresh Kumar Ravichandran
Naresh Kumar Ravichandran
UJUnsang Jung
Unsang Jung
MJMansik Jeon
Mansik Jeon
JKJeehyun Kim
Jeehyun Kim

31 July 2020 in IEEE Photonics Journal
Verified
Journal Article
Open access
Ruchire Eranga WijesingheRuchire Eranga Wijesinghe
Ruchire Eranga Wijesinghe
JLJaeyul Lee
Jaeyul Lee
DJDeokmin Jeon
Deokmin Jeon
PKPIL UN KIM
PIL UN KIM
SHSangyeob Han
Sangyeob Han
JKJeehyun Kim
Jeehyun Kim
The accurate screening of otitis media (OM) lies in clarifying the numerous confounding and quantitative factors that are discovered during primary inspections. Increased awareness about bacterial biofilms and inflammation has allowed researchers to develop a better understanding of the bacterial infections that occur in the middle ear. In this study, four live guinea pigs were inoculated with Streptococcus pneumonia to induce OM-related inflammatory changes. Since optical techniques have been effectively used for diagnosis in medicine, low-coherence interferometry-based optical coherence tomography (OCT) was employed for depth-resolved high-resolution data screening. Multiple locations of the tympanic membrane (TM), mastoid mucosa, and round window membrane were examined to assess inflammatory changes. We performed qualitative assessments and thickness quantifications and investigated the variations due to adverse inflammatory affects. The findings of the present study provide a better understanding of S. pneumonia bacteria caused inflammatory changes in middle ear and it further provides a fundamental platform for future clinical utility.