Juan Serrano-Arellano

Dr. Juan Serrano-Arellano

División de Estudios de Posgrado e Investigación-DEPI, TecNM_ Instituto Tecnológico de Pachuca, Pachuca, Hidalgo, Mexico
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
MRMaría Magdalena Villar Ramos
María Magdalena Villar Ramos
Iván Hernández-PérezIván Hernández-Pérez
Iván Hernández-Pérez
KCKarla María Aguilar Castro
Karla María Aguilar Castro
IZIvett Zavala-Guillén
Ivett Zavala-Guillén
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Among the alternatives for improving the thermal comfort conditions inside buildings are the thermally activated building systems (TABS). They are embedded in different building components to improve the indoor air temperature. In this work, a review and analysis of the state of the art of TABS was carried out to identify their potential to improve thermal comfort conditions and provide energy savings. Furthermore, this study presents the gaps identified in the literature so that researchers can develop future studies on TABS. The articles found were classified and analyzed in four sections, considering their implementation in roofs, walls, floors, and the whole envelope. In addition, aspects related to the configuration of the TABS and the fluid (speed, temperature, and mass flow rate) were analyzed. It was found that when TABS are implemented in roofs, walls, and floors, a reduction in the indoor temperature of a building of up to 14.4 °C can be obtained. Within the limitations of the TABS, the complexity and costs of their implementation compared to the use of air conditioning systems are reported. However, the TABS can provide energy savings of up to 50%.

27 April 2018 in Energies
Verified
Journal Article
Open access
PDF file
JGJuan Garcia
Juan Garcia
José Manuel Riesco-AvilaJosé Manuel Riesco-Avila
José Manuel Riesco-Avila
FEFrancisco Elizalde-Blancas
Francisco Elizalde-Blancas
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Flow maldistribution represents a problem of particular interest in the engineering field for several thermal systems. In flat plate solar collectors, the thermal efficiency strongly depends on the flow distribution through the riser tubes, where a uniform distribution causes a uniform temperature distribution and therefore a higher efficiency. In this work, a Computational Fluid Dynamics (CFD) numerical analysis has been carried out using the commercial software FLUENT®, in order to determine the flow distribution, pressure drop and hence the thermal efficiency of a solar collector with distribution flow plates inside the manifolds. The obtained numerical solution for this type of thermal systems has been validated with experimental results available in literature for laminar and turbulent flow. Four distribution plate configurations were analyzed. Results show that using two distribution plates in each of both manifolds improves the flow uniformity up to 40% under the same operating conditions when distribution plates are not used. Besides, it is shown that there exists an increase in the overall pressure drop which is practically negligible for the tilt angles commonly employed in the installation of flat plate solar collectors in Mexico. The use of closed end distribution plates on the dividing and combining manifolds allows the thermal efficiency to become close to the ideal thermal efficiency which is obtained with a uniform flow distribution.

16 February 2024 in Journal of Thermal Science and Engineering Applications
Verified
Journal Article
Closed access
PDF file
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
RRR. Román-Aguilar
R. Román-Aguilar
JVJulio Valle-Hernández
Julio Valle-Hernández
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
R404A refrigerant is one of the most widely used hydrofluorocarbons in the commercial refrigeration industry for low and medium temperatures. However, this refrigerant contributes negatively to the environment due to its high global warming potential (GWP = 3943), and for several years, it has been labeled as one of the refrigerants that should be phased out. The present study theoretically evaluates low-GWP refrigerants as a replacement alternative to R404A, including R407H, R442A, R449A, R454A, R454C, R455A, R459B, and R465A. The analysis focuses on the comparison between relative differences in the volumetric flow in the compressor suction and the coefficient of performance for four configurations of the vapor compression cycle, such as the basic cycle, the cycle with an internal heat exchanger, the cycle with direct injection, and the cycle with a sub-cooler. According to the proposed operating conditions of evaporation temperature (−10 °C and −40 °C) and condensation temperature (40 °C and 55 °C), R454A could be the best long-term replacement option for its low GWP, energy performance, and direct fit for any configuration. R459B could also be considered a viable option, but with certain design modifications. On the contrary, the refrigerants R465A, R455A, and R454C would be discarded because they present a greater non-adaptation to the compressor in each configuration analyzed.

15 June 2020 in Energies
Verified
Journal Article
Open access
PDF file
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Juan Manuel BelmanJuan Manuel Belman
Juan Manuel Belman
JXJesús Xamán
Jesús Xamán
KCKarla María Aguilar Castro
Karla María Aguilar Castro
EMEdgar Vicente Macías-Melo
Edgar Vicente Macías-Melo
A study was conducted on the double diffusion by natural convection because of the effects of heat and pollutant sources placed at one third of the closed cavity’s height. The heat and pollution sources were analyzed separately and simultaneously. The study was considered for the Rayleigh number interval 10 4   ≤   R a   ≤   10 10 . Three case studies were analyzed: (1) differentially heated closed cavity with only heat sources; (2) differentially heated closed cavity with only pollutant sources; and (3) differentially heated closed cavity with heat and pollutant sources. The governing equations of the system were solved through the finite volume technique. The turbulence solution was done with the k-ε model. The dominant influence of the buoyancy forces was found due to the pollutant diffusion on the flow pattern, and an internal temperature increase was observed with the simple diffusion. The most critical case was obtained through the double diffusive convection with an average temperature value of 32.57 °C. Finally, the Nusselt number increased as the Rayleigh number increased; however, the Sherwood number either increased or decreased when the Rayleigh number increased. The highest mean concentration recorded was 2808 ppm; this was found with the value R a = 10 6 .

29 March 2023 in Plants
Verified
Journal Article
Open access
PDF file
Roberto Augusto Ferriz-MartínezRoberto Augusto Ferriz-Martínez
Roberto Augusto Ferriz-Martínez
NENayeli Espinosa-Villarreal
Nayeli Espinosa-Villarreal
Jorge Chavez-ServinJorge Chavez-Servin
Jorge Chavez-Servin
AMAdán Mercado-Luna
Adán Mercado-Luna
Karina de la Torre-CarbotKarina de la Torre-Carbot
Karina de la Torre-Carbot
Teresa García-GascaTeresa García-Gasca
Teresa García-Gasca
Amaranth has many interesting features, both nutritional and otherwise, that make it attractive as a food crop. Plants grown in greenhouses have higher yields but lower nutritional value compared to those grown in open fields. This prompted an interest in studying viable elicitors for the production of amaranth. Small hydrogen peroxide (H2O2) concentrations for foliar spraying from 0 to 18 mM have been used in greenhouse amaranth cultivation. The objective of this work was to evaluate the effect of foliar application of H2O2 megadoses on growth parameters, total phenolic compounds, condensed tannins, anthocyanins, and the antioxidant capacity of leaves and seeds of amaranth grown in a greenhouse setting. The seed of the Amaranthus hypochondriacus L. species was used. The concentrations of H2O2 analyzed were 0, 125, 250 and 400 mM, with 11 applications throughout the growing cycle. The variable data were subjected to an analysis of variance (ANOVA), followed by a Tukey’s post hoc test (95% CI, p < 0.05). The results on chlorophyll, growth parameters and proximal chemical analysis showed no statistical difference between the control group versus the treatment groups. A greater number of favorable changes in the different variables studied were observed with the 125 mM H2O2 treatment, including the increase in antioxidant capacity measured by FRAP. The seed showed a considerable increase in TFC with all treatments and responded better to the 250 mM H2O2 treatment in the case of DPPH (an increase of 30%) and TPC (an increase of 44%). A 28% increase in anthocyanin content was observed with the treatment of 400 mM H2O2. The use of H2O2 may be an appropriate strategy to enhance the production of antioxidant compounds in amaranth without affecting growth or its basic proximal chemical composition. More studies are required in this regard.

1 October 2015 in Solar Energy
Verified
Journal Article
Closed access
Juan Serrano-ArellanoJuan Serrano-Arellano
Juan Serrano-Arellano
Miguel Gijón-RiveraMiguel Gijón-Rivera
Miguel Gijón-Rivera
Jorge Chavez-ServinJorge Chavez-Servin
Jorge Chavez-Servin
Karina de la Torre-CarbotKarina de la Torre-Carbot
Karina de la Torre-Carbot
JXJ. Xamán
J. Xamán
JBJ.M. Belman-Flores
J.M. Belman-Flores